====== Switch, data center devices, at plant — GLO ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:switch_data_center_devices_at_plant__glo|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Switch, data center devices, at plant [GLO], per 1 p. EF v3.1 climate change 373.3 kg CO2 eq (Monte Carlo 95 % interval 301.7–543.6). Main contributors: Printed wiring board, surface mounted, unspec., Pb free, at … 82 %; Power supply unit, at plant 12 %; Chassis, network main devices, at plant 6 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Switch, data center devices, at plant | | Dataset UUID / graph id | ''%%97d025b2-b522-3476-9e1c-fbc352a9e7b2%%'' / ''%%activity:switch_data_center_devices_at_plant__glo%%'' | | Reference product, unit | Switch, data center devices, at plant, 1 p | | Location | GLO — Data for global average for switches | | Time period | 2023-01/2029-12 | | Category | electronics / internet network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The data set represents the production of switch for data centers; UUID: 97d025b2-b522-3476-9e1c-fbc352a9e7b2 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Switch, data center devices, at plant (GLO). All results are given per unit of the reference flow. ==== System boundary ==== The dataset represents switches used in data centres. Steel, chassis, and wiring boards are the main components. ==== Technology ==== Typical switches for data centers ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Printed wiring board, surface mounted, unspec., Pb free, at plant | technosphere | GLO | 1.89 | kg | lognormal, GSD² 1.23 | — | 81.5 | ████████████████ | | | Power supply unit, at plant | technosphere | GLO | 2 | p | lognormal, GSD² 1.23 | — | 12.2 | ██ | | | Chassis, network main devices, at plant | technosphere | GLO | 5 | kg | lognormal, GSD² 1.23 | — | 6.0 | █ | | | Steel, low-alloyed, at plant | technosphere | RER | 0.4 | kg | lognormal, GSD² 1.23 | — | 0.2 | · | | | Hot rolling, steel | technosphere | RER | 0.4 | kg | lognormal, GSD² 1.23 | — | 0.0 | · | | ==== Data quality ==== 0 of 5 direct exchanges carry a declared pedigree, 5 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH) | | extrapolations | Average technology | | sampling procedure | Literature & own estimations | | production volume | unknown | | uncertainty adjustments | none | | validation details | Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.644** | 2.098 | 4.081 | 1.4 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.63** | 0.8756 | 4.489 | 2.32 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **371.5** | 300 | 540.3 | 1.35 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1938** | 0.1428 | 0.3364 | 1.53 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **373.3** | 301.7 | 543.6 | 1.35 | | EF-particulate Matter | Impact on human health | disease incidence | **1.481e-05** | 1.301e-05 | 2.438e-05 | 1.37 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3157** | 2823 | 6977 | 1.63 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **65.34** | 53.21 | 112.8 | 1.48 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3223** | 2894 | 7070 | 1.62 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.5073** | 0.3894 | 0.9805 | 1.61 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.956** | 1.041 | 12.66 | 3.54 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **4.717** | 3.617 | 8.045 | 1.49 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.204e-07** | 4.397e-07 | 1.473e-06 | 1.89 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.490e-07** | 1.152e-07 | 2.587e-07 | 1.53 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.695e-07** | 5.858e-07 | 1.663e-06 | 1.73 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.155e-05** | 3.105e-05 | 1.322e-04 | 2.1 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.301e-06** | 7.639e-07 | 2.695e-06 | 1.94 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.285e-05** | 3.201e-05 | 1.341e-04 | 2.07 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **76.21** | 23.2 | 538.2 | 4.93 | | Land use | Soil quality index | pt (soil quality index) | **3033** | 2248 | 5989 | 1.65 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.253e-05** | 2.228e-05 | 5.687e-05 | 1.63 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.631** | 1.359 | 2.572 | 1.38 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **4853** | 3978 | 7791 | 1.42 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.2578** | 0.1728 | 0.4021 | 1.53 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **65.52** | -1.047e+05 | 5.269e+04 | — | Climate change 373.3 kg CO2 eq per p. Main contributors: Printed wiring board, surface mounted, unspec., Pb free, at … 82 %; Power supply unit, at plant 12 %; Chassis, network main devices, at plant 6 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Printed wiring board, surface mounted, unspec., Pb free, at … 82 %; Power supply unit, at plant 12 %; Chassis, network main devices, at plant 6 %. Most sensitive exchanges (Section 6.3): Printed wiring board, surface mounted, unspec., Pb free, at plant [GLO] (-15.0 / +18.3 %); Power supply unit, at plant [GLO] (-2.2 / +2.8 %); Chassis, network main devices, at plant [GLO] (-1.1 / +1.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.644 | 4.13 | 0.640 | | Climate change-Biogenic | 1.63 | 1.63 | 1.000 | | Climate change-Fossil | 371.5 | 371.5 | 1.000 | | Climate change-Land use and land use change | 0.1938 | 0.1938 | 1.000 | | Climate change | 373.3 | 373.3 | 1.000 | | EF-particulate Matter | 1.481e-05 | 1.481e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 3157 | 3252 | 0.971 | | Ecotoxicity, freshwater_organics | 65.34 | 55.38 | 1.180 | | Ecotoxicity, freshwater | 3223 | 3225 | 0.999 | | Eutrophication marine | 0.5073 | 0.5073 | 1.000 | | Eutrophication, freshwater | 1.956 | 1.956 | 1.000 | | Eutrophication, terrestrial | 4.717 | 4.952 | 0.952 | | Human toxicity, cancer_inorganics | 5.204e-07 | 5.174e-07 | 1.006 | | Human toxicity, cancer_organics | 1.490e-07 | 1.490e-07 | 1.000 | | Human toxicity, cancer | 6.695e-07 | 6.665e-07 | 1.004 | | Human toxicity, non-cancer_inorganics | 4.155e-05 | 4.127e-05 | 1.007 | | Human toxicity, non-cancer_organics | 1.301e-06 | 1.301e-06 | 1.000 | | Human toxicity, non-cancer | 4.285e-05 | 4.257e-05 | 1.007 | | Ionising radiation, human health | 76.21 | 76.21 | 1.000 | | Land use | 3033 | 2612 | 1.161 | | Ozone depletion | 3.253e-05 | 3.253e-05 | 1.000 | | Photochemical ozone formation - human health | 1.631 | 1.631 | 1.000 | | Resource use, fossils | 4853 | 4855 | 1.000 | | Resource use, minerals and metals | 0.2578 | 0.2573 | 1.002 | | Water use | 65.52 | 74.54 | 0.879 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 373.2 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.867e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Printed wiring board, surface mounted, unspec., Pb free, at plant [GLO] | 1.89 kg | ×0.816 / ×1.22 | lognormal, GSD² 1.23 | -15.0 / +18.3 | 21.4 (Resource use, minerals and metals) | | Power supply unit, at plant [GLO] | 2 p | ×0.816 / ×1.22 | lognormal, GSD² 1.23 | -2.2 / +2.8 | 4.0 (Ecotoxicity, freshwater_organics) | | Chassis, network main devices, at plant [GLO] | 5 kg | ×0.816 / ×1.22 | lognormal, GSD² 1.23 | -1.1 / +1.3 | 6.0 (Human toxicity, non-cancer_organics) | | Steel, low-alloyed, at plant [RER] | 0.4 kg | ×0.816 / ×1.22 | lognormal, GSD² 1.23 | -0.0 / +0.1 | 0.1 (EF-particulate Matter) | | Hot rolling, steel [RER] | 0.4 kg | ×0.816 / ×1.22 | lognormal, GSD² 1.23 | -0.0 / +0.0 | 0.0 (EF-particulate Matter) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 373.3 kg CO2 eq per p (95 % interval 301.7–543.6). Dominant contributors: Printed wiring board, surface mounted, unspec., Pb free, at … 82 %; Power supply unit, at plant 12 %; Chassis, network main devices, at plant 6 %. Most sensitive: Printed wiring board, surface mounted, unspec., Pb free, at plant [GLO] (-15.0 / +18.3 %); Power supply unit, at plant [GLO] (-2.2 / +2.8 %); Chassis, network main devices, at plant [GLO] (-1.1 / +1.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 5/5 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 373.3 in [301.7, 543.6] | | time period declared | **PASS** | 2023-01/2029-12 | | geography is a known location code | **PASS** | GLO | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].