====== Electricity, medium voltage, residual mix — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_medium_voltage_residual_mix__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, medium voltage, residual mix [CH], per 1 kWh. EF v3.1 climate change 0.04057 kg CO2 eq (Monte Carlo 95 % interval 0.03835–0.05813). Main contributors: Electricity, high voltage, residual mix 95 %; Sulfur hexafluoride 3 %; Transmission network, electricity, medium voltage 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, medium voltage, residual mix | | Dataset UUID / graph id | ''%%982def76-ac2d-31f8-863e-345a725af988%%'' / ''%%activity:electricity_medium_voltage_residual_mix__ch%%'' | | Reference product, unit | Electricity, medium voltage, residual mix, 1 kWh | | Location | CH — Data apply to untracked electricity supplied in "&T53&". Geographical classification according to IEA.Transmission network, losses and emissions are taken from Itten, Frischknecht and Stucki (2014): LCI of Electricity Mixes and Grid. | | Time period | 1992/2020 | | Category | electricity / supply mix | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transformation from high to medium voltage as well as the transmission of electricity at medium voltage.; UUID:982def76-ac2d-31f8-863e-345a725af988 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, medium voltage, residual mix (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in CH, the transmission network and direct SF6-emissions to air. Electricity losses during medium-voltage transmission and transformation from high-voltage are accounted for. ==== Technology ==== Average technology used to transmit and distribute electricity. Includes underground and overhead lines, as well as air-, vacuum- and SF6-insulated high-to-medium voltage switching stations. Electricity production according to related datasets ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, high voltage, residual mix | technosphere | CH | 1.0098 | kWh | lognormal, GSD² 1.13 | — | 95.1 | ███████████████████ | | | Transmission network, electricity, medium voltage | technosphere | CH | 1.8628e-08 | km | lognormal, GSD² 3.28 | — | 1.4 | · | | | Sulphur hexafluoride, liquid, at plant | technosphere | RER | 5.5686e-08 | kg | lognormal, GSD² 1.25 | — | 0.0 | · | | | Sulfur hexafluoride | elementary | air/Unknown | 5.5686e-08 | kg | lognormal, GSD² 1.58 | — | 3.5 | █ | | | Waste Heat | elementary | soil/Unknown | 0.0017652 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.033538 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | ==== Data quality ==== 0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Rolf Frischknecht (TREEZE); data entry: Rolf Frischknecht (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | sampling procedure | Statistical data | | uncertainty adjustments | none | | validation details | 10.05.2022 | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.011e-04** | 9.568e-05 | 1.538e-04 | 1.28 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.037e-04** | 8.330e-05 | 1.888e-04 | 1.54 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04027** | 0.03803 | 0.05777 | 1.23 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.940e-04** | 1.058e-04 | 3.922e-04 | 1.95 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.04057** | 0.03835 | 0.05813 | 1.23 | | EF-particulate Matter | Impact on human health | disease incidence | **7.663e-09** | 5.381e-09 | 1.334e-08 | 1.61 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1361** | 0.1238 | 0.3615 | 1.76 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.003818** | 0.003503 | 0.009009 | 1.64 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.14** | 0.1274 | 0.376 | 1.74 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **8.261e-05** | 7.325e-05 | 1.126e-04 | 1.25 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **9.389e-06** | 7.557e-06 | 5.074e-05 | 2.65 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **4.069e-04** | 3.665e-04 | 5.729e-04 | 1.26 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.347e-11** | 1.146e-11 | 3.880e-11 | 1.82 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.012e-11** | 3.478e-11 | 1.107e-10 | 1.79 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.359e-11** | 5.305e-11 | 1.342e-10 | 1.61 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.700e-10** | 5.513e-10 | 1.510e-09 | 1.65 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.527e-11** | 2.035e-11 | 5.887e-11 | 1.74 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.953e-10** | 5.736e-10 | 1.566e-09 | 1.64 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.322** | 0.4425 | 7.056 | 4.31 | | Land use | Soil quality index | pt (soil quality index) | **3.25** | 2.013 | 5.602 | 1.68 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **9.437e-09** | 5.828e-09 | 1.794e-08 | 1.78 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.693e-04** | 1.564e-04 | 2.579e-04 | 1.29 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **12.24** | 9.992 | 16.01 | 1.27 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.254e-07** | 1.827e-07 | 4.734e-07 | 1.62 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.122** | -88.53 | 43.28 | — | Climate change 0.04057 kg CO2 eq per kWh. Main contributors: Electricity, high voltage, residual mix 95 %; Sulfur hexafluoride 3 %; Transmission network, electricity, medium voltage 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, high voltage, residual mix 95 %; Sulfur hexafluoride 3 %; Transmission network, electricity, medium voltage 1 %. Most sensitive exchanges (Section 6.3): Electricity, high voltage, residual mix [CH] (-10.7 / +12.0 %); Transmission network, electricity, medium voltage [CH] (-1.0 / +3.1 %); Sulfur hexafluoride [air/Unknown] (-1.3 / +2.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.011e-04 | 1.864e-04 | 0.542 | | Climate change-Biogenic | 1.037e-04 | 1.035e-04 | 1.002 | | Climate change-Fossil | 0.04027 | 0.04021 | 1.002 | | Climate change-Land use and land use change | 1.940e-04 | 1.940e-04 | 1.000 | | Climate change | 0.04057 | 0.04051 | 1.002 | | EF-particulate Matter | 7.663e-09 | 7.661e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1361 | 0.1787 | 0.762 | | Ecotoxicity, freshwater_organics | 0.003818 | 0.003668 | 1.041 | | Ecotoxicity, freshwater | 0.14 | 0.1823 | 0.768 | | Eutrophication marine | 8.261e-05 | 8.238e-05 | 1.003 | | Eutrophication, freshwater | 9.389e-06 | 9.381e-06 | 1.001 | | Eutrophication, terrestrial | 4.069e-04 | 5.089e-04 | 0.800 | | Human toxicity, cancer_inorganics | 1.347e-11 | 1.234e-11 | 1.091 | | Human toxicity, cancer_organics | 6.012e-11 | 6.011e-11 | 1.000 | | Human toxicity, cancer | 7.359e-11 | 7.245e-11 | 1.016 | | Human toxicity, non-cancer_inorganics | 5.700e-10 | 4.894e-10 | 1.165 | | Human toxicity, non-cancer_organics | 2.527e-11 | 2.532e-11 | 0.998 | | Human toxicity, non-cancer | 5.953e-10 | 5.147e-10 | 1.156 | | Ionising radiation, human health | 1.322 | 1.322 | 1.000 | | Land use | 3.25 | 2.62 | 1.241 | | Ozone depletion | 9.437e-09 | 9.432e-09 | 1.001 | | Photochemical ozone formation - human health | 1.693e-04 | 1.697e-04 | 0.998 | | Resource use, fossils | 12.24 | 12.24 | 1.000 | | Resource use, minerals and metals | 2.254e-07 | 2.215e-07 | 1.018 | | Water use | 0.122 | 0.1223 | 0.998 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.04046 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 700.5 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, high voltage, residual mix [CH] | 1.01 kWh | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -10.7 / +12.0 | 12.6 (Ionising radiation, human health) | | Transmission network, electricity, medium voltage [CH] | 1.863e-08 km | ×0.312 / ×3.21 | lognormal, GSD² 3.28 | -1.0 / +3.1 | 106.4 (Human toxicity, cancer_inorganics) | | Sulfur hexafluoride [air/Unknown] | 5.569e-08 kg | ×0.637 / ×1.57 | lognormal, GSD² 1.58 | -1.3 / +2.0 | 2.0 (Climate change-Fossil) | | Sulphur hexafluoride, liquid, at plant [RER] | 5.569e-08 kg | ×0.803 / ×1.24 | lognormal, GSD² 1.25 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.04057 kg CO2 eq per kWh (95 % interval 0.03835–0.05813). Dominant contributors: Electricity, high voltage, residual mix 95 %; Sulfur hexafluoride 3 %; Transmission network, electricity, medium voltage 1 %. Most sensitive: Electricity, high voltage, residual mix [CH] (-10.7 / +12.0 %); Transmission network, electricity, medium voltage [CH] (-1.0 / +3.1 %); Sulfur hexafluoride [air/Unknown] (-1.3 / +2.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1.002; categories within ±5 %: 17/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.04057 in [0.03835, 0.05813] | | time period declared | **PASS** | 1992/2020 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht R. (2022) 2022 - Energy label for passenger cars - Frischknecht. treeze Ltd. — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].