====== Electricity, high voltage, operation storage pumps, ENTSO, 2020, at grid — DE ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_high_voltage_operation_storage_pumps_entso_2020_at_grid__de|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, high voltage, operation storage pumps, ENTSO, 2020, at grid [DE], per 1 kWh. EF v3.1 climate change 0.385 kg CO2 eq (Monte Carlo 95 % interval 0.3199–0.52). Main contributors: Electricity mix, operation storage pumps, ENTSO, 2020, at pl… 99 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, high voltage, operation storage pumps, ENTSO, 2020, at grid | | Dataset UUID / graph id | ''%%9d2751da-9114-3e85-9726-3f21810c1d21%%'' / ''%%activity:electricity_high_voltage_operation_storage_pumps_entso_2020_at_grid__de%%'' | | Reference product, unit | Electricity, high voltage, operation storage pumps, ENTSO, 2020, at grid, 1 kWh | | Location | DE — Germany | | Time period | 2020/2020 | | Category | electricity / production mix | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Transmission losses are taken from Itten, Frischknecht and Stucki (2014): LCI of Electricity Mixes and Grid.; UUID:9d2751da-9114-3e85-9726-3f21810c1d21 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, high voltage, operation storage pumps, ENTSO, 2020, at grid (DE). All results are given per unit of the reference flow. ==== System boundary ==== This dataset describes the transmission of the electricity mix used for the operation of storage pumps in Germany in 2018 and includes the high voltage network infrastructure (including long-distance transport), transmission losses and air pollutant emissions. Not included are electricity losses due to long-distance transport since they are assumed to be contained in the total electricity losses of the country network. ==== Technology ==== Average technology ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity mix, operation storage pumps, ENTSO, 2020, at plant | technosphere | DE | 1.021 | kWh | lognormal, GSD² 1.13 | — | 99.4 | ████████████████████ | | | Transmission network, electricity, high voltage | technosphere | CH | 6.8199e-09 | km | lognormal, GSD² 3.28 | — | 0.3 | · | | | Nitrous Oxide | elementary | air/Unknown | 5.0000e-06 | kg | lognormal, GSD² 1.85 | — | 0.4 | · | | | Waste Heat | elementary | soil/Unknown | 0.0037789 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.071799 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Ozone | elementary | air/Unknown | 4.5000e-06 | kg | lognormal, GSD² 1.85 | — | 0.0 | · | | ==== Data quality ==== 0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Rolf Frischknecht (TREEZE); data entry: Rolf Frischknecht (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Some generic datasets from ecoinvent have been used. | | sampling procedure | Statistics | | uncertainty adjustments | | | validation details | 09.05.2022 | | time period comment | Time of publications | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **6.263e-04** | 5.374e-04 | 8.552e-04 | 1.27 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.009062** | 0.005915 | 0.01488 | 1.59 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.3759** | 0.3105 | 0.5117 | 1.28 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.954e-05** | 3.495e-05 | 1.018e-04 | 1.73 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.385** | 0.3199 | 0.52 | 1.28 | | EF-particulate Matter | Impact on human health | disease incidence | **3.723e-09** | 3.245e-09 | 6.506e-09 | 1.42 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.115** | 0.7865 | 2.246 | 1.74 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.007503** | 0.005341 | 0.02873 | 2.35 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.122** | 0.7928 | 2.266 | 1.74 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.660e-04** | 2.264e-04 | 3.705e-04 | 1.29 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.392e-04** | 1.907e-04 | 0.002007 | 3.26 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.001341** | 0.001161 | 0.002003 | 1.32 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.436e-11** | 2.786e-11 | 1.414e-10 | 2.3 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.044e-10** | 7.466e-11 | 1.673e-10 | 1.52 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.388e-10** | 1.143e-10 | 2.684e-10 | 1.55 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.262e-09** | 1.726e-09 | 8.712e-09 | 2.28 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.117e-11** | 7.173e-11 | 1.459e-10 | 1.43 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.343e-09** | 1.825e-09 | 8.824e-09 | 2.24 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.1741** | 0.04817 | 1.163 | 5.22 | | Land use | Soil quality index | pt (soil quality index) | **3.567** | 2.29 | 6.279 | 1.69 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.775e-09** | 4.383e-09 | 2.337e-08 | 2.32 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **5.093e-04** | 4.370e-04 | 8.757e-04 | 1.42 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **5.948** | 4.679 | 11.38 | 1.55 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.490e-07** | 3.090e-07 | 7.050e-07 | 1.54 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.04409** | -96.13 | 51.16 | — | Climate change 0.385 kg CO2 eq per kWh. Main contributors: Electricity mix, operation storage pumps, ENTSO, 2020, at pl… 99 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity mix, operation storage pumps, ENTSO, 2020, at pl… 99 %. Most sensitive exchanges (Section 6.3): Electricity mix, operation storage pumps, ENTSO, 2020, at plant [DE] (-11.1 / +12.5 %); Transmission network, electricity, high voltage [CH] (-0.2 / +0.6 %); Nitrous Oxide [air/Unknown] (-0.2 / +0.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 6.263e-04 | 5.439e-04 | 1.151 | | Climate change-Biogenic | 0.009062 | 0.009062 | 1.000 | | Climate change-Fossil | 0.3759 | 0.3759 | 1.000 | | Climate change-Land use and land use change | 4.954e-05 | 4.954e-05 | 1.000 | | Climate change | 0.385 | 0.385 | 1.000 | | EF-particulate Matter | 3.723e-09 | 3.723e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.115 | 1.155 | 0.965 | | Ecotoxicity, freshwater_organics | 0.007503 | 0.007407 | 1.013 | | Ecotoxicity, freshwater | 1.122 | 1.162 | 0.966 | | Eutrophication marine | 2.660e-04 | 2.660e-04 | 1.000 | | Eutrophication, freshwater | 5.392e-04 | 5.392e-04 | 1.000 | | Eutrophication, terrestrial | 0.001341 | 0.001706 | 0.786 | | Human toxicity, cancer_inorganics | 3.436e-11 | 2.786e-11 | 1.233 | | Human toxicity, cancer_organics | 1.044e-10 | 1.044e-10 | 1.000 | | Human toxicity, cancer | 1.388e-10 | 1.323e-10 | 1.049 | | Human toxicity, non-cancer_inorganics | 2.262e-09 | 2.019e-09 | 1.120 | | Human toxicity, non-cancer_organics | 8.117e-11 | 8.117e-11 | 1.000 | | Human toxicity, non-cancer | 2.343e-09 | 2.100e-09 | 1.116 | | Ionising radiation, human health | 0.1741 | 0.1741 | 1.000 | | Land use | 3.567 | 2.919 | 1.222 | | Ozone depletion | 7.775e-09 | 7.775e-09 | 1.000 | | Photochemical ozone formation - human health | 5.093e-04 | 5.093e-04 | 1.000 | | Resource use, fossils | 5.948 | 5.948 | 1.000 | | Resource use, minerals and metals | 3.490e-07 | 3.412e-07 | 1.023 | | Water use | 0.04409 | 0.06645 | 0.663 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.385 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 555.6 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity mix, operation storage pumps, ENTSO, 2020, at plant [DE] | 1.021 kWh | ×0.888 / ×1.13 | lognormal, GSD² 1.13 | -11.1 / +12.5 | 12.6 (Climate change-Biogenic) | | Transmission network, electricity, high voltage [CH] | 6.820e-09 km | ×0.312 / ×3.21 | lognormal, GSD² 3.28 | -0.2 / +0.6 | 22.9 (Resource use, minerals and metals) | | Nitrous Oxide [air/Unknown] | 5.000e-06 kg | ×0.546 / ×1.83 | lognormal, GSD² 1.85 | -0.2 / +0.3 | 0.3 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Electricity, high voltage, operation storage pumps, ENTSO, 2020, at gr… [FR] | 0.05454 kg CO2 eq | 0.385 | 7.06 | same dataset name, other location | | bafu | Electricity, high voltage, operation storage pumps, ENTSO, 2020, at gr… [CH] | 0.0925 kg CO2 eq | 0.385 | 4.16 | same dataset name, other location | | bafu | Electricity, high voltage, operation storage pumps, ENTSO, 2020, at gr… [AT] | 0.1041 kg CO2 eq | 0.385 | 3.70 | same dataset name, other location | | bafu | Electricity, high voltage, operation storage pumps, ENTSO, 2020, at gr… [IT] | 0.4675 kg CO2 eq | 0.385 | 0.82 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.385 kg CO2 eq per kWh (95 % interval 0.3199–0.52). Dominant contributors: Electricity mix, operation storage pumps, ENTSO, 2020, at pl… 99 %. Most sensitive: Electricity mix, operation storage pumps, ENTSO, 2020, at plant [DE] (-11.1 / +12.5 %); Transmission network, electricity, high voltage [CH] (-0.2 / +0.6 %); Nitrous Oxide [air/Unknown] (-0.2 / +0.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 18/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.385 in [0.3199, 0.52] | | time period declared | **PASS** | 2020/2020 | | geography is a known location code | **PASS** | DE | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Report — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].