====== Electricity, production mix photovoltaic, at plant — NL ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_production_mix_photovoltaic_at_plant__nl|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, production mix photovoltaic, at plant [NL], per 1 kWh. EF v3.1 climate change 0.03054 kg CO2 eq (Monte Carlo 95 % interval 0.02655–0.08721). Main contributors: 570 kWp open ground installation, multi-Si, on open ground 30 %; 570 kWp open ground installation, single-Si, on open ground 15 %; 156 kWp flat-roof installation, multi-Si, on roof 10 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 10 %; 3kWp flat roof installation, multi-Si, on roof 6 %; 156 kWp flat-roof installation, single-Si, on roof 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, production mix photovoltaic, at plant | | Dataset UUID / graph id | ''%%9d73dbba-69c9-3b9b-a7c2-63be328479e9%%'' / ''%%activity:electricity_production_mix_photovoltaic_at_plant__nl%%'' | | Reference product, unit | Electricity, production mix photovoltaic, at plant, 1 kWh | | Location | NL — undefined | | Time period | 2005-01/2018-12 | | Category | electricity by fuel / photovoltaic | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Annual output of grid-connected PV power plants differentiated for roof-top, facade and centralized power plants. Technology and installation type breakdown based on literature (IEA-PVPS Task 1 and Fraunhofer ISE reports) and expert estimates. Average yield based on population-weighted average according to Breyer & Schmid (2010), corrected by performance ratio as specified in IEA-PVPS Task 12 methodology guidelines. The lifetime of PV systems is estimated at 30 years based on the PEFCR PV electricity. Technology: Electricity production with grid-connected photovoltaic power plants. Time period: Time of publications Version: 1 Energy values: Undefined 100.0 Production volume: Unknown. Local category: Photovoltaik Local subcategory: Kraftwerke UVEK 2022 source file:174-photovoltaics-global-supply-chain-v2.5._X-elec-RER.xml UUID: 9d73dbba-69c9-3b9b-a7c2-63be328479e9 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, production mix photovoltaic, at plant (NL). All results are given per unit of the reference flow. ==== System boundary ==== Production mix of photovoltaic electricity in the country. Annual output, Roof-Top: 937, Annual output, Facade: 656 kWh/kWp, Annual output, centralized PV systems: 994 kWh/kWp. Amount of solar energy transformed to electricity. Waste heat emission due to losses of electricity in the system. ==== Technology ==== Electricity production with grid-connected photovoltaic power plants. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | 570 kWp open ground installation, multi-Si, on open ground | technosphere | RER | 1.7520e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 29.6 | ██████ | | | 570 kWp open ground installation, single-Si, on open ground | technosphere | RER | 9.2785e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 15.4 | ███ | | | 156 kWp flat-roof installation, multi-Si, on roof | technosphere | CH | 2.3373e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 10.3 | ██ | | | 93 kWp slanted-roof installation, multi-Si, panel, mounted, on roof | technosphere | CH | 4.3563e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 10.1 | ██ | | | 3kWp flat roof installation, multi-Si, on roof | technosphere | RER | 6.0770e-07 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 6.1 | █ | | | 156 kWp flat-roof installation, single-Si, on roof | technosphere | CH | 1.2378e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 5.4 | █ | | | 93 kWp slanted-roof installation, single-Si, panel, mounted, on roof | technosphere | CH | 2.3071e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 5.3 | █ | | | 3kWp slanted-roof installation, multi-Si, panel, mounted, on roof | technosphere | RER | 4.9882e-07 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 4.9 | █ | | | 3kWp flat roof installation, single-Si, on roof | technosphere | RER | 3.2184e-07 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 3.2 | █ | | | 3kWp slanted-roof installation, single-Si, panel, mounted, on roof | technosphere | RER | 2.6418e-07 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 2.6 | █ | | | 3kWp slanted-roof installation, CIS, panel, mounted, on roof | technosphere | CH | 1.1393e-07 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.0 | · | | | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof | technosphere | CH | 1.3791e-07 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.0 | · | | | 570 kWp open ground installation, CIS, on open ground | technosphere | RER | 5.4749e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.8 | · | | | 570 kWp open ground installation, CdTe, on open ground | technosphere | RER | 6.6275e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.8 | · | | | 3kWp facade installation, multi-Si, panel, mounted, at building | technosphere | RER | 5.7876e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.6 | · | | | 93 kWp slanted-roof installation, multi-Si, laminated, integrated, on roof | technosphere | CH | 2.6138e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.5 | · | | | 3kWp facade installation, multi-Si, laminated, integrated, at building | technosphere | RER | 5.7876e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.5 | · | | | 3kWp facade installation, single-Si, panel, mounted, at building | technosphere | RER | 3.0651e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 93 kWp slanted-roof installation, single-Si, laminated, integrated, on roof | technosphere | CH | 1.3843e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 3kWp slanted-roof installation, micro-Si, panel, mounted, on roof | technosphere | RER | 1.7988e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 3kWp facade installation, single-Si, laminated, integrated, at building | technosphere | RER | 3.0651e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 3kWp slanted-roof installation, multi-Si, laminated, integrated, on roof | technosphere | RER | 2.9929e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 570 kWp open ground installation, micro-Si, on open ground | technosphere | RER | 8.6445e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 3kWp slanted-roof installation, single-Si, laminated, integrated, on roof | technosphere | RER | 1.5851e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp slanted-roof installation, CdTe, laminated, integrated, on roof | technosphere | CH | 8.2746e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp slanted-roof installation, CIS, laminated, integrated, on roof | technosphere | CH | 6.8355e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp slanted-roof installation, micro-Si, laminated, integrated, on roof | technosphere | RER | 1.0793e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | Treatment, sewage, from residence, to wastewater treatment, class 2 | technosphere | CH | 3.4050e-06 | m3 | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Tap water, water balance according to MoeK 2013, at user | technosphere | NL | 0.0037834 | kg | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Energy, Solar, Converted | elementary | natural resource | 3.8503 | MJ | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.25027 | MJ | lognormal, GSD² 1.05 | — | 0.0 | · | | | Water vapour | elementary | air/Unknown | 3.7834e-07 | m3 | lognormal, GSD² 1.51 | — | 0.0 | · | | ==== Data quality ==== 30 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 2.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Use of PV technology data investigated for other countries (Switzerland). Correction of average yield with Swiss data. | | sampling procedure | Statistical data and model calculations | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Time of publications | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.326e-04** | 1.245e-04 | 3.316e-04 | 1.66 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.360e-04** | 8.686e-05 | 5.848e-04 | 2.64 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03038** | 0.0264 | 0.08668 | 1.82 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.218e-05** | 1.953e-05 | 5.156e-05 | 1.64 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.03054** | 0.02655 | 0.08721 | 1.82 | | EF-particulate Matter | Impact on human health | disease incidence | **1.149e-09** | 1.083e-09 | 7.343e-09 | 2.63 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1736** | 0.1552 | 0.6585 | 2.07 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.003716** | 0.003552 | 0.01187 | 1.82 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.1773** | 0.1587 | 0.6665 | 2.06 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.747e-05** | 3.296e-05 | 1.093e-04 | 1.83 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.122e-05** | 1.727e-05 | 1.254e-04 | 2.82 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.851e-04** | 2.614e-04 | 7.762e-04 | 1.72 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.333e-11** | 1.388e-11 | 5.359e-11 | 2.02 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.125e-12** | 7.054e-12 | 2.482e-11 | 1.94 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.145e-11** | 2.244e-11 | 7.437e-11 | 1.86 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.480e-10** | 8.150e-10 | 2.683e-09 | 1.87 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.711e-11** | 3.249e-11 | 9.028e-11 | 1.67 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.851e-10** | 8.552e-10 | 2.740e-09 | 1.84 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.007992** | 0.003056 | 0.07243 | 5.11 | | Land use | Soil quality index | pt (soil quality index) | **4.131** | 2.906 | 7.131 | 1.57 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **9.879e-10** | 8.765e-10 | 3.079e-09 | 1.89 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **9.332e-05** | 8.803e-05 | 2.537e-04 | 1.72 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.4064** | 0.36 | 1.204 | 1.84 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.897e-06** | 1.597e-06 | 4.021e-06 | 1.59 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.01532** | -9.809 | 4.877 | — | Climate change 0.03054 kg CO2 eq per kWh. Main contributors: 570 kWp open ground installation, multi-Si, on open ground 30 %; 570 kWp open ground installation, single-Si, on open ground 15 %; 156 kWp flat-roof installation, multi-Si, on roof 10 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 10 %; 3kWp flat roof installation, multi-Si, on roof 6 %; 156 kWp flat-roof installation, single-Si, on roof 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: 570 kWp open ground installation, multi-Si, on open ground 30 %; 570 kWp open ground installation, single-Si, on open ground 15 %; 156 kWp flat-roof installation, multi-Si, on roof 10 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 10 %; 3kWp flat roof installation, multi-Si, on roof 6 %; 156 kWp flat-roof installation, single-Si, on roof 5 %. Most sensitive exchanges (Section 6.3): 570 kWp open ground installation, multi-Si, on open ground [RER] (-5.2 / +6.3 %); 570 kWp open ground installation, single-Si, on open ground [RER] (-2.7 / +3.3 %); 156 kWp flat-roof installation, multi-Si, on roof [CH] (-1.8 / +2.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.326e-04 | 1.394e-04 | 0.952 | | Climate change-Biogenic | 1.360e-04 | 1.360e-04 | 1.000 | | Climate change-Fossil | 0.03038 | 0.03038 | 1.000 | | Climate change-Land use and land use change | 2.218e-05 | 2.218e-05 | 1.000 | | Climate change | 0.03054 | 0.03054 | 1.000 | | EF-particulate Matter | 1.149e-09 | 1.149e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.1736 | 0.1774 | 0.979 | | Ecotoxicity, freshwater_organics | 0.003716 | 0.003168 | 1.173 | | Ecotoxicity, freshwater | 0.1773 | 0.1802 | 0.984 | | Eutrophication marine | 3.747e-05 | 3.746e-05 | 1.000 | | Eutrophication, freshwater | 2.122e-05 | 2.122e-05 | 1.000 | | Eutrophication, terrestrial | 2.851e-04 | 2.952e-04 | 0.966 | | Human toxicity, cancer_inorganics | 1.333e-11 | 1.326e-11 | 1.005 | | Human toxicity, cancer_organics | 8.125e-12 | 8.124e-12 | 1.000 | | Human toxicity, cancer | 2.145e-11 | 2.138e-11 | 1.003 | | Human toxicity, non-cancer_inorganics | 7.480e-10 | 7.444e-10 | 1.005 | | Human toxicity, non-cancer_organics | 3.711e-11 | 3.708e-11 | 1.001 | | Human toxicity, non-cancer | 7.851e-10 | 7.814e-10 | 1.005 | | Ionising radiation, human health | 0.007992 | 0.007992 | 1.000 | | Land use | 4.131 | 4.091 | 1.010 | | Ozone depletion | 9.879e-10 | 9.879e-10 | 1.000 | | Photochemical ozone formation - human health | 9.332e-05 | 9.332e-05 | 1.000 | | Resource use, fossils | 0.4064 | 0.4065 | 1.000 | | Resource use, minerals and metals | 1.897e-06 | 1.881e-06 | 1.008 | | Water use | 0.01532 | 0.01524 | 1.005 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.03051 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 82.25 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | 570 kWp open ground installation, multi-Si, on open ground [RER] | 1.752e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -5.2 / +6.3 | 13.1 (Land use) | | 570 kWp open ground installation, single-Si, on open ground [RER] | 9.278e-09 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -2.7 / +3.3 | 6.4 (Land use) | | 156 kWp flat-roof installation, multi-Si, on roof [CH] | 2.337e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -1.8 / +2.2 | 2.4 (Human toxicity, non-cancer_organics) | | 93 kWp slanted-roof installation, multi-Si, panel, mounted, on roof [CH] | 4.356e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -1.8 / +2.1 | 2.3 (Climate change-Biogenic) | | 3kWp flat roof installation, multi-Si, on roof [RER] | 6.077e-07 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -1.1 / +1.3 | 3.3 (Resource use, minerals and metals) | | 156 kWp flat-roof installation, single-Si, on roof [CH] | 1.238e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.9 / +1.1 | 2.0 (Water use) | | 93 kWp slanted-roof installation, single-Si, panel, mounted, on roof [CH] | 2.307e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.9 / +1.1 | 2.2 (Water use) | | 3kWp slanted-roof installation, multi-Si, panel, mounted, on roof [RER] | 4.988e-07 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.9 / +1.0 | 2.7 (Resource use, minerals and metals) | | 3kWp flat roof installation, single-Si, on roof [RER] | 3.218e-07 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.6 / +0.7 | 1.7 (Resource use, minerals and metals) | | 3kWp slanted-roof installation, single-Si, panel, mounted, on roof [RER] | 2.642e-07 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.4 / +0.5 | 1.4 (Resource use, minerals and metals) | | 3kWp slanted-roof installation, CIS, panel, mounted, on roof [CH] | 1.139e-07 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.2 / +0.2 | 0.9 (Ozone depletion) | | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof [CH] | 1.379e-07 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.2 / +0.2 | 0.7 (Resource use, minerals and metals) | | 570 kWp open ground installation, CIS, on open ground [RER] | 5.475e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.2 | 0.7 (Ozone depletion) | | 570 kWp open ground installation, CdTe, on open ground [RER] | 6.628e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.2 | 0.5 (Land use) | | 3kWp facade installation, multi-Si, panel, mounted, at building [RER] | 5.788e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.3 (Resource use, minerals and metals) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Electricity, production mix photovoltaic, at plant [IL] | 0.01673 kg CO2 eq | 0.03054 | 1.83 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [ZA] | 0.01723 kg CO2 eq | 0.03054 | 1.77 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [MX] | 0.01749 kg CO2 eq | 0.03054 | 1.75 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [CL] | 0.01751 kg CO2 eq | 0.03054 | 1.74 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [US] | 0.01921 kg CO2 eq | 0.03054 | 1.59 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [BE] | 0.0319 kg CO2 eq | 0.03054 | 0.96 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [FI] | 0.03271 kg CO2 eq | 0.03054 | 0.93 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [GB] | 0.0339 kg CO2 eq | 0.03054 | 0.90 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [NO] | 0.03502 kg CO2 eq | 0.03054 | 0.87 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [IE] | 0.0361 kg CO2 eq | 0.03054 | 0.85 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.03054 kg CO2 eq per kWh (95 % interval 0.02655–0.08721). Dominant contributors: 570 kWp open ground installation, multi-Si, on open ground 30 %; 570 kWp open ground installation, single-Si, on open ground 15 %; 156 kWp flat-roof installation, multi-Si, on roof 10 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 10 %; 3kWp flat roof installation, multi-Si, on roof 6 %; 156 kWp flat-roof installation, single-Si, on roof 5 %. Most sensitive: 570 kWp open ground installation, multi-Si, on open ground [RER] (-5.2 / +6.3 %); 570 kWp open ground installation, single-Si, on open ground [RER] (-2.7 / +3.3 %); 156 kWp flat-roof installation, multi-Si, on roof [CH] (-1.8 / +2.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.6e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 24/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.03054 in [0.02655, 0.08721] | | time period declared | **PASS** | 2005-01/2018-12 | | geography is a known location code | **PASS** | NL | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].