====== Assembly, generator and motor, cogen unit 160kWe — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:assembly_generator_and_motor_cogen_unit_160kwe__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Assembly, generator and motor, cogen unit 160kWe [RER], per 1 p. EF v3.1 climate change 1354 kg CO2 eq (Monte Carlo 95 % interval 981.5–2318). Main contributors: Reinforcing steel, at plant 58 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 22 %; Natural gas, burned in industrial furnace 1MWth 18 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Assembly, generator and motor, cogen unit 160kWe | | Dataset UUID / graph id | ''%%a1aa8129-0e49-3cda-9ac1-3e8484c7b459%%'' / ''%%activity:assembly_generator_and_motor_cogen_unit_160kwe__rer%%'' | | Reference product, unit | Assembly, generator and motor, cogen unit 160kWe, 1 p | | Location | RER — Data refers to a plant in Switzerland, assumed valid for Europe (RER) | | Time period | 1990-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Inventory refers to infrastructure of an existing natural gas cogeneration plant (lambda=1 motor, 160kWe, operation start 1987) at Jakobsberg, Basel, Switzerland.; UUID: a1aa8129-0e49-3cda-9ac1-3e8484c7b459 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Assembly, generator and motor, cogen unit 160kWe (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes the most important materials used for production. It includes also the transport of these materials and the energy and water needed for production. ==== Technology ==== Component of a specific cogeneration unit installed in Switzerland. Technology at end of 1980s. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Reinforcing steel, at plant | technosphere | RER | 560 | kg | lognormal, GSD² 2.06 | — | 58.0 | ████████████ | | | Light fuel oil, burned in industrial furnace 1MW, non-modulating | technosphere | RER | 3150 | MJ | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 22.2 | ████ | | | Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 3150 | MJ | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 17.7 | ████ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 64.2 | kWh | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 1.3 | · | | | Transport, freight, rail | technosphere | RER | 336 | tkm | lognormal, GSD² 2.49 | — | 0.4 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 28 | tkm | lognormal, GSD² 2.49 | — | 0.4 | · | | | Treatment, pig iron production effluent, to wastewater treatment, class 3 | technosphere | CH | 0.672 | m3 | lognormal, GSD² 3 | — | 0.0 | · | | | Water | elementary | natural resource | 0.84 | m3 | lognormal, GSD² 3 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 231 | MJ | lognormal, GSD² 1.55 | (3,3,3,3,4,3) | 0.0 | · | | | Water | elementary | water/Unknown | 0.798 | m3 | lognormal, GSD² 2.52 | — | 0.0 | · | | ==== Data quality ==== 4 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 3.0 · temporal 3.0 · geographical 3.0 · technological 4.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | see Geography/Text | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: had passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.373** | 1.547 | 4.799 | 1.78 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.105** | 1.521 | 9.036 | 2.46 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1351** | 977.8 | 2309 | 1.55 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.3281** | 0.2156 | 0.7503 | 1.93 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1354** | 981.5 | 2318 | 1.55 | | EF-particulate Matter | Impact on human health | disease incidence | **5.074e-05** | 2.933e-05 | 1.256e-04 | 2.07 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3271** | 2283 | 8872 | 2 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **138.3** | 95.52 | 365.1 | 2.1 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3410** | 2417 | 9153 | 1.98 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.703** | 0.4731 | 1.441 | 1.76 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.3423** | 0.1914 | 1.257 | 2.56 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **6.801** | 4.452 | 14.33 | 1.78 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.371e-07** | 3.773e-07 | 2.302e-06 | 2.5 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.875e-07** | 2.255e-07 | 8.773e-07 | 1.99 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.025e-06** | 6.324e-07 | 3.099e-06 | 2.23 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.526e-05** | 1.528e-05 | 8.434e-05 | 2.43 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.077e-07** | 3.709e-07 | 1.091e-06 | 1.76 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.577e-05** | 1.573e-05 | 8.544e-05 | 2.41 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **241.5** | 77.51 | 1528 | 4.8 | | Land use | Soil quality index | pt (soil quality index) | **3766** | 2650 | 9297 | 1.91 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.504e-05** | 1.848e-05 | 4.686e-05 | 1.62 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **3.542** | 2.411 | 7.455 | 1.75 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.661e+04** | 1.208e+04 | 2.921e+04 | 1.58 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.00561** | 0.002992 | 0.01182 | 2.02 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **144.8** | -3.455e+05 | 1.988e+05 | — | Climate change 1354 kg CO2 eq per p. Main contributors: Reinforcing steel, at plant 58 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 22 %; Natural gas, burned in industrial furnace 1MWth 18 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Reinforcing steel, at plant 58 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 22 %; Natural gas, burned in industrial furnace 1MWth 18 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. Most sensitive exchanges (Section 6.3): Reinforcing steel, at plant [RER] (-29.4 / +59.8 %); Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] (-7.7 / +11.9 %); Natural gas, burned in industrial furnace 1MWth [CH] (-6.2 / +9.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.373 | 2.785 | 0.852 | | Climate change-Biogenic | 3.105 | 3.105 | 1.000 | | Climate change-Fossil | 1351 | 1351 | 1.000 | | Climate change-Land use and land use change | 0.3281 | 0.3281 | 1.000 | | Climate change | 1354 | 1354 | 1.000 | | EF-particulate Matter | 5.074e-05 | 5.074e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 3271 | 3399 | 0.962 | | Ecotoxicity, freshwater_organics | 138.3 | 137.9 | 1.003 | | Ecotoxicity, freshwater | 3410 | 3528 | 0.966 | | Eutrophication marine | 0.703 | 0.703 | 1.000 | | Eutrophication, freshwater | 0.3423 | 0.3423 | 1.000 | | Eutrophication, terrestrial | 6.801 | 7.272 | 0.935 | | Human toxicity, cancer_inorganics | 6.371e-07 | 6.331e-07 | 1.006 | | Human toxicity, cancer_organics | 3.875e-07 | 3.875e-07 | 1.000 | | Human toxicity, cancer | 1.025e-06 | 1.021e-06 | 1.004 | | Human toxicity, non-cancer_inorganics | 2.526e-05 | 2.512e-05 | 1.006 | | Human toxicity, non-cancer_organics | 5.077e-07 | 5.076e-07 | 1.000 | | Human toxicity, non-cancer | 2.577e-05 | 2.563e-05 | 1.005 | | Ionising radiation, human health | 241.5 | 241.5 | 1.000 | | Land use | 3766 | 3125 | 1.205 | | Ozone depletion | 2.504e-05 | 2.504e-05 | 1.000 | | Photochemical ozone formation - human health | 3.542 | 3.542 | 1.000 | | Resource use, fossils | 1.661e+04 | 1.662e+04 | 1.000 | | Resource use, minerals and metals | 0.00561 | 0.005569 | 1.007 | | Water use | 144.8 | 151 | 0.959 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1354 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 2.310e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Reinforcing steel, at plant [RER] | 560 kg | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -29.4 / +59.8 | 100.4 (Human toxicity, cancer_inorganics) | | Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] | 3150 MJ | ×0.651 / ×1.54 | lognormal, GSD² 1.55 | -7.7 / +11.9 | 14.0 (Ozone depletion) | | Natural gas, burned in industrial furnace 1MWth [CH] | 3150 MJ | ×0.651 / ×1.54 | lognormal, GSD² 1.55 | -6.2 / +9.5 | 15.5 (Ozone depletion) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 64.2 kWh | ×0.651 / ×1.54 | lognormal, GSD² 1.55 | -0.5 / +0.7 | 5.2 (Climate change-Biogenic) | | Transport, freight, rail [RER] | 336 tkm | ×0.409 / ×2.44 | lognormal, GSD² 2.49 | -0.2 / +0.6 | 7.1 (Land use) | | Transport, freight, lorry, fleet average [RER] | 28 tkm | ×0.409 / ×2.44 | lognormal, GSD² 2.49 | -0.2 / +0.6 | 9.0 (Climate change-Land use and land use change) | | Treatment, pig iron production effluent, to wastewater treatment, class 3 [CH] | 0.672 m3 | ×0.341 / ×2.93 | lognormal, GSD² 3 | -0.0 / +0.0 | 0.1 (Land use) | | Water [natural resource] | 0.84 m3 | ×0.341 / ×2.93 | lognormal, GSD² 3 | -0.0 / +0.0 | 48.2 (Water use) | | Water [water/Unknown] | 0.798 m3 | ×0.404 / ×2.47 | lognormal, GSD² 2.52 | -0.0 / +0.0 | 34.9 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1354 kg CO2 eq per p (95 % interval 981.5–2318). Dominant contributors: Reinforcing steel, at plant 58 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 22 %; Natural gas, burned in industrial furnace 1MWth 18 %; Electricity, medium voltage, production ENTSO-E, at grid 1 %. Most sensitive: Reinforcing steel, at plant [RER] (-29.4 / +59.8 %); Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] (-7.7 / +11.9 %); Natural gas, burned in industrial furnace 1MWth [CH] (-6.2 / +9.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1354 in [981.5, 2318] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].