====== Connector, computer, peripherical type, at plant — GLO ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:connector_computer_peripherical_type_at_plant__glo|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Connector, computer, peripherical type, at plant [GLO], per 1 kg. EF v3.1 climate change 6.567 kg CO2 eq (Monte Carlo 95 % interval 5.372–11.97). Main contributors: Electricity, medium voltage, production GLO, at grid 46 %; Printed wiring board mounting plant 19 %; Steel, low-alloyed, at plant 10 %; Brass, at plant 9 %; Polyethylene, HDPE, granulate, at plant 6 %; Polyvinylchloride, at regional storage 6 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Connector, computer, peripherical type, at plant | | Dataset UUID / graph id | ''%%a2425cb3-89fe-32ba-abe6-2e1a5b51e72c%%'' / ''%%activity:connector_computer_peripherical_type_at_plant__glo%%'' | | Reference product, unit | Connector, computer, peripherical type, at plant, 1 kg | | Location | GLO — Data represent a global valuable composition of a serial computer port. | | Time period | 2023-01/2029-12 | | Category | electronics / component | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The data represent a current computer peripherical type connector, as used in current computers. Material data are taken from product sheets of producers. The energy demand is estimated based on literature. Infrastructure and transport efforts rough estimations. The dataset represents 1 kg of computer peripherical type connectors with a weight of 10 gram/unit. In 2023 updates, only production efforts are modified to reflect improved energy efficiency in the manufacturing; UUID: a2425cb3-89fe-32ba-abe6-2e1a5b51e72c This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Connector, computer, peripherical type, at plant (GLO). All results are given per unit of the reference flow. ==== System boundary ==== This dataset covers raw material input, energy consumption, infrastructure and transport efforts for the production of computer peripherical type connectors. ==== Technology ==== average connector production technology, based on literature and assumptions ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, medium voltage, production GLO, at grid | technosphere | GLO | 5.208 | kWh | lognormal, GSD² 1.65 | — | 45.6 | █████████ | | | Printed wiring board mounting plant | technosphere | GLO | 2.0800e-07 | p | lognormal, GSD² 3.18 | — | 19.5 | ████ | | | Steel, low-alloyed, at plant | technosphere | RER | 0.302 | kg | lognormal, GSD² 1.45 | — | 9.8 | ██ | | | Brass, at plant | technosphere | CH | 0.29 | kg | lognormal, GSD² 2.19 | — | 9.4 | ██ | | | Polyethylene, HDPE, granulate, at plant | technosphere | RER | 0.183 | kg | lognormal, GSD² 1.45 | — | 6.3 | █ | | | Polyvinylchloride, at regional storage | technosphere | RER | 0.162 | kg | lognormal, GSD² 2.19 | — | 5.8 | █ | | | Copper, primary, at refinery | technosphere | GLO | 0.075 | kg | lognormal, GSD² 1.45 | — | 3.1 | █ | | | Transport, freight, lorry, fleet average | technosphere | RER | 0.1001 | tkm | lognormal, GSD² 2.19 | — | 0.3 | · | | | Transport, freight, rail | technosphere | RER | 0.6006 | tkm | lognormal, GSD² 2.19 | — | 0.2 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 23.436 | MJ | lognormal, GSD² 1.73 | — | 0.0 | · | | ==== Data quality ==== 0 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH) | | extrapolations | see Geography & Technology | | sampling procedure | literature | | uncertainty adjustments | | | validation details | Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.1028** | 0.07494 | 0.1906 | 1.59 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.0225** | 0.01319 | 0.06149 | 2.18 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.541** | 5.338 | 11.92 | 1.51 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004291** | 0.002766 | 0.008691 | 1.81 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.567** | 5.372 | 11.97 | 1.51 | | EF-particulate Matter | Impact on human health | disease incidence | **4.085e-07** | 3.433e-07 | 9.246e-07 | 1.67 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **45.87** | 41.49 | 121.7 | 1.74 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.6079** | 0.5285 | 1.659 | 1.88 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **46.48** | 42.21 | 123.1 | 1.74 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.008595** | 0.006836 | 0.01849 | 1.7 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.0284** | 0.01559 | 0.1942 | 3.65 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.1012** | 0.07679 | 0.2282 | 1.75 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.322e-08** | 1.054e-08 | 4.236e-08 | 2.01 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.531e-09** | 1.933e-09 | 7.249e-09 | 1.9 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.575e-08** | 1.338e-08 | 4.664e-08 | 1.88 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.283e-06** | 9.421e-07 | 3.904e-06 | 2.06 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.623e-08** | 4.405e-08 | 1.683e-07 | 1.96 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.360e-06** | 1.009e-06 | 4.026e-06 | 2.02 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.551** | 0.4885 | 11.28 | 4.99 | | Land use | Soil quality index | pt (soil quality index) | **93.44** | 54.21 | 314.6 | 2.41 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.512e-07** | 1.705e-07 | 6.515e-07 | 1.99 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.0295** | 0.02421 | 0.05663 | 1.55 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **95.62** | 81.6 | 179.4 | 1.52 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **5.741e-04** | 2.638e-04 | 0.001393 | 2.42 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.8076** | -3006 | 1573 | — | Climate change 6.567 kg CO2 eq per kg. Main contributors: Electricity, medium voltage, production GLO, at grid 46 %; Printed wiring board mounting plant 19 %; Steel, low-alloyed, at plant 10 %; Brass, at plant 9 %; Polyethylene, HDPE, granulate, at plant 6 %; Polyvinylchloride, at regional storage 6 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, medium voltage, production GLO, at grid 46 %; Printed wiring board mounting plant 19 %; Steel, low-alloyed, at plant 10 %; Brass, at plant 9 %; Polyethylene, HDPE, granulate, at plant 6 %; Polyvinylchloride, at regional storage 6 %. Most sensitive exchanges (Section 6.3): Printed wiring board mounting plant [GLO] (-13.2 / +41.1 %); Electricity, medium voltage, production GLO, at grid [GLO] (-17.7 / +28.9 %); Brass, at plant [CH] (-5.0 / +10.9 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.1028 | 0.1052 | 0.977 | | Climate change-Biogenic | 0.0225 | 0.0225 | 1.000 | | Climate change-Fossil | 6.541 | 6.541 | 1.000 | | Climate change-Land use and land use change | 0.004291 | 0.004291 | 1.000 | | Climate change | 6.567 | 6.567 | 1.000 | | EF-particulate Matter | 4.085e-07 | 4.085e-07 | 1.000 | | Ecotoxicity, freshwater_inorganics | 45.87 | 47.38 | 0.968 | | Ecotoxicity, freshwater_organics | 0.6079 | 0.6031 | 1.008 | | Ecotoxicity, freshwater | 46.48 | 47.95 | 0.969 | | Eutrophication marine | 0.008595 | 0.008595 | 1.000 | | Eutrophication, freshwater | 0.0284 | 0.0284 | 1.000 | | Eutrophication, terrestrial | 0.1012 | 0.104 | 0.973 | | Human toxicity, cancer_inorganics | 1.322e-08 | 1.318e-08 | 1.003 | | Human toxicity, cancer_organics | 2.531e-09 | 2.531e-09 | 1.000 | | Human toxicity, cancer | 1.575e-08 | 1.571e-08 | 1.003 | | Human toxicity, non-cancer_inorganics | 1.283e-06 | 1.281e-06 | 1.002 | | Human toxicity, non-cancer_organics | 7.623e-08 | 7.623e-08 | 1.000 | | Human toxicity, non-cancer | 1.360e-06 | 1.358e-06 | 1.002 | | Ionising radiation, human health | 1.551 | 1.551 | 1.000 | | Land use | 93.44 | 64.09 | 1.458 | | Ozone depletion | 2.512e-07 | 2.512e-07 | 1.000 | | Photochemical ozone formation - human health | 0.0295 | 0.0295 | 1.000 | | Resource use, fossils | 95.62 | 95.64 | 1.000 | | Resource use, minerals and metals | 5.741e-04 | 5.714e-04 | 1.005 | | Water use | 0.8076 | 0.8507 | 0.949 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 6.567 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 2.358e+04 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Printed wiring board mounting plant [GLO] | 2.080e-07 p | ×0.322 / ×3.11 | lognormal, GSD² 3.18 | -13.2 / +41.1 | 140.9 (Land use) | | Electricity, medium voltage, production GLO, at grid [GLO] | 5.208 kWh | ×0.612 / ×1.63 | lognormal, GSD² 1.65 | -17.7 / +28.9 | 43.4 (Climate change-Land use and land use change) | | Brass, at plant [CH] | 0.29 kg | ×0.464 / ×2.16 | lognormal, GSD² 2.19 | -5.0 / +10.9 | 58.6 (Resource use, minerals and metals) | | Polyvinylchloride, at regional storage [RER] | 0.162 kg | ×0.464 / ×2.16 | lognormal, GSD² 2.19 | -3.1 / +6.7 | 68.3 (Ozone depletion) | | Steel, low-alloyed, at plant [RER] | 0.302 kg | ×0.695 / ×1.44 | lognormal, GSD² 1.45 | -3.0 / +4.3 | 5.3 (Ecotoxicity, freshwater_organics) | | Polyethylene, HDPE, granulate, at plant [RER] | 0.183 kg | ×0.695 / ×1.44 | lognormal, GSD² 1.45 | -1.9 / +2.8 | 6.1 (Resource use, fossils) | | Copper, primary, at refinery [GLO] | 0.075 kg | ×0.695 / ×1.44 | lognormal, GSD² 1.45 | -0.9 / +1.3 | 23.0 (Human toxicity, non-cancer_inorganics) | | Transport, freight, lorry, fleet average [RER] | 0.1001 tkm | ×0.464 / ×2.16 | lognormal, GSD² 2.19 | -0.2 / +0.3 | 2.0 (Climate change-Land use and land use change) | | Transport, freight, rail [RER] | 0.6006 tkm | ×0.464 / ×2.16 | lognormal, GSD² 2.19 | -0.1 / +0.2 | 0.7 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 6.567 kg CO2 eq per kg (95 % interval 5.372–11.97). Dominant contributors: Electricity, medium voltage, production GLO, at grid 46 %; Printed wiring board mounting plant 19 %; Steel, low-alloyed, at plant 10 %; Brass, at plant 9 %; Polyethylene, HDPE, granulate, at plant 6 %; Polyvinylchloride, at regional storage 6 %. Most sensitive: Printed wiring board mounting plant [GLO] (-13.2 / +41.1 %); Electricity, medium voltage, production GLO, at grid [GLO] (-17.7 / +28.9 %); Brass, at plant [CH] (-5.0 / +10.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 6.567 in [5.372, 11.97] | | time period declared | **PASS** | 2023-01/2029-12 | | geography is a known location code | **PASS** | GLO | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].