====== 280 kWp flat-roof installation, single-Si, on roof — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:280_kwp_flat_roof_installation_single_si_on_roof__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 280 kWp flat-roof installation, single-Si, on roof [CH], per 1 p. EF v3.1 climate change 2.347e+05 kg CO2 eq (Monte Carlo 95 % interval 1.107e+05–1.207e+06). Main contributors: Photovoltaic panel, single-Si, at regional storage 72 %; Flat roof construction, on roof 16 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 280 kWp photovoltaic plant, at plant 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 280 kWp flat-roof installation, single-Si, on roof | | Dataset UUID / graph id | ''%%a3944834-0b5b-31d9-bb6a-042333074458%%'' / ''%%activity:280_kwp_flat_roof_installation_single_si_on_roof__ch%%'' | | Reference product, unit | 280 kWp flat-roof installation, single-Si, on roof, 1 p | | Location | CH — Installation in CH | | Time period | 2006-01/2018-12 | | Category | electricity by fuel / photovoltaic\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 280kWp and a life time of 30 years installed in Switzerland. The efficiency of single-Si PV modules is 17.9% (Fraunhofer ISE Photovoltaics Report 2019). The share of rejected or replaced PV modules is estimated at 3%. The inverter is assumed to be replaced once during the service life of the PV system.; Synonyms: monocrystalline, single crystalline, silicon; UUID: a3944834-0b5b-31d9-bb6a-042333074458 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 280 kWp flat-roof installation, single-Si, on roof (CH). All results are given per unit of the reference flow. ==== System boundary ==== All components (modules, mounting system, electric installation, inverter) for the installation of a 280 kWp photovoltaic plant, energy use for the mounting, transport of materials to the place of installation. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic panel, single-Si, at regional storage | technosphere | RER | 1479 | m2 | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 72.0 | ██████████████ | | | Flat roof construction, on roof | technosphere | RER | 1435.9 | m2 | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 15.9 | ███ | | | Inverter, 500kW, at plant | technosphere | RER | 1.6182 | p | lognormal, GSD² 4.47 | (2,4,1,1,1,5) | 8.5 | ██ | | | Treatment, c-Si PV module | technosphere | RER | 19450 | kg | lognormal, GSD² 2.77 | (3,4,1,1,1,5) | 2.3 | · | | | Electric installation, 280 kWp photovoltaic plant, at plant | technosphere | CH | 1 | p | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 1.2 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 3180.4 | tkm | lognormal, GSD² 2.99 | — | 0.3 | · | | | Electricity, low voltage, at grid | technosphere | CH | 21.467 | kWh | lognormal, GSD² 2.77 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 77.28 | MJ | lognormal, GSD² 2.06 | — | 0.0 | · | | ==== Data quality ==== 6 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.83 · completeness 4.0 · temporal 1.33 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | Publication of plant specific (partly aggregated) data and literature information. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **893.9** | 469.4 | 4228 | 3.08 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1045** | 311.8 | 7885 | 5.13 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.335e+05** | 1.101e+05 | 1.198e+06 | 3.45 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **162.4** | 88.67 | 638.4 | 2.84 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.347e+05** | 1.107e+05 | 1.207e+06 | 3.45 | | EF-particulate Matter | Impact on human health | disease incidence | **0.007597** | 0.004102 | 0.06803 | 4.28 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.398e+06** | 5.909e+05 | 8.966e+06 | 4.12 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.541e+04** | 1.419e+04 | 1.391e+05 | 3.22 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.423e+06** | 6.087e+05 | 9.102e+06 | 4.09 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **318.5** | 124.1 | 1807 | 4.02 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **117.4** | 63.66 | 1034 | 4.19 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1929** | 933 | 1.005e+04 | 3.46 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.409e-05** | 5.398e-05 | 6.001e-04 | 3.31 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.871e-05** | 2.530e-05 | 3.437e-04 | 3.92 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.428e-04** | 8.275e-05 | 9.028e-04 | 3.34 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.004729** | 0.003081 | 0.03164 | 3.3 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.637e-04** | 1.420e-04 | 0.001127 | 2.92 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.004993** | 0.003254 | 0.0325 | 3.26 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **5.681e+04** | 1.593e+04 | 5.864e+05 | 6.93 | | Land use | Soil quality index | pt (soil quality index) | **1.537e+06** | 6.397e+05 | 9.091e+06 | 4.01 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.006286** | 0.002811 | 0.03655 | 3.81 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **682.1** | 353.6 | 3459 | 3.3 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3.142e+06** | 1.474e+06 | 1.613e+07 | 3.47 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **7.943** | 2.777 | 44.44 | 4.17 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **2.123e+05** | -8.636e+07 | 5.388e+07 | — | Climate change 2.347e+05 kg CO2 eq per p. Main contributors: Photovoltaic panel, single-Si, at regional storage 72 %; Flat roof construction, on roof 16 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 280 kWp photovoltaic plant, at plant 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic panel, single-Si, at regional storage 72 %; Flat roof construction, on roof 16 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 280 kWp photovoltaic plant, at plant 1 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel, single-Si, at regional storage [RER] (-55.4 / +240.1 %); Flat roof construction, on roof [RER] (-12.2 / +52.9 %); Inverter, 500kW, at plant [RER] (-6.5 / +28.2 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 893.9 | 939.7 | 0.951 | | Climate change-Biogenic | 1045 | 1045 | 1.000 | | Climate change-Fossil | 2.335e+05 | 2.335e+05 | 1.000 | | Climate change-Land use and land use change | 162.4 | 162.4 | 1.000 | | Climate change | 2.347e+05 | 2.347e+05 | 1.000 | | EF-particulate Matter | 0.007597 | 0.007597 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.398e+06 | 1.423e+06 | 0.982 | | Ecotoxicity, freshwater_organics | 2.541e+04 | 2.159e+04 | 1.177 | | Ecotoxicity, freshwater | 1.423e+06 | 1.444e+06 | 0.985 | | Eutrophication marine | 318.5 | 318.5 | 1.000 | | Eutrophication, freshwater | 117.4 | 117.4 | 1.000 | | Eutrophication, terrestrial | 1929 | 1993 | 0.968 | | Human toxicity, cancer_inorganics | 8.409e-05 | 8.364e-05 | 1.005 | | Human toxicity, cancer_organics | 5.871e-05 | 5.871e-05 | 1.000 | | Human toxicity, cancer | 1.428e-04 | 1.423e-04 | 1.003 | | Human toxicity, non-cancer_inorganics | 0.004729 | 0.004708 | 1.004 | | Human toxicity, non-cancer_organics | 2.637e-04 | 2.635e-04 | 1.001 | | Human toxicity, non-cancer | 0.004993 | 0.004972 | 1.004 | | Ionising radiation, human health | 5.681e+04 | 5.681e+04 | 1.000 | | Land use | 1.537e+06 | 1.242e+06 | 1.237 | | Ozone depletion | 0.006286 | 0.006286 | 1.000 | | Photochemical ozone formation - human health | 682.1 | 682.1 | 1.000 | | Resource use, fossils | 3.142e+06 | 3.142e+06 | 1.000 | | Resource use, minerals and metals | 7.943 | 7.816 | 1.016 | | Water use | 2.123e+05 | 2.084e+05 | 1.019 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2.344e+05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 4.566e+08 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic panel, single-Si, at regional storage [RER] | 1479 m2 | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -55.4 / +240.1 | 325.7 (Water use) | | Flat roof construction, on roof [RER] | 1436 m2 | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -12.2 / +52.9 | 71.6 (Ionising radiation, human health) | | Inverter, 500kW, at plant [RER] | 1.618 p | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -6.5 / +28.2 | 137.3 (Human toxicity, non-cancer_organics) | | Treatment, c-Si PV module [RER] | 1.945e+04 kg | ×0.369 / ×2.71 | lognormal, GSD² 2.77 | -1.4 / +3.9 | 6.7 (Climate change-Land use and land use change) | | Electric installation, 280 kWp photovoltaic plant, at plant [CH] | 1 p | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -0.9 / +3.8 | 67.0 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, fleet average [RER] | 3180 tkm | ×0.342 / ×2.92 | lognormal, GSD² 2.99 | -0.2 / +0.5 | 2.7 (Climate change-Land use and land use change) | | Electricity, low voltage, at grid [CH] | 21.47 kWh | ×0.369 / ×2.71 | lognormal, GSD² 2.77 | -0.0 / +0.0 | 0.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 2.347e+05 kg CO2 eq per p (95 % interval 1.107e+05–1.207e+06). Dominant contributors: Photovoltaic panel, single-Si, at regional storage 72 %; Flat roof construction, on roof 16 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 280 kWp photovoltaic plant, at plant 1 %. Most sensitive: Photovoltaic panel, single-Si, at regional storage [RER] (-55.4 / +240.1 %); Flat roof construction, on roof [RER] (-12.2 / +52.9 %); Inverter, 500kW, at plant [RER] (-6.5 / +28.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2.347e+05 in [1.107e+05, 1.207e+06] | | time period declared | **PASS** | 2006-01/2018-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].