====== Cogen unit 200kWe, components for electricity only — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:cogen_unit_200kwe_components_for_electricity_only__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 200kWe, components for electricity only [RER], per 1 p. EF v3.1 climate change 1.102e+04 kg CO2 eq (Monte Carlo 95 % interval 8765–1.876e+04). Main contributors: Electric parts of cogen unit 160kWe 52 %; Generator 200kWe 36 %; Assembly, generator and motor, cogen unit 160kWe 12 %. Status: final control: 0 failed, 1 warning(s) (Section 7). ^ Item ^ Value ^ | Dataset name | Cogen unit 200kWe, components for electricity only | | Dataset UUID / graph id | ''%%a417512e-3012-33e1-ae0e-18a3165240a5%%'' / ''%%activity:cogen_unit_200kwe_components_for_electricity_only__rer%%'' | | Reference product, unit | Cogen unit 200kWe, components for electricity only, 1 p | | Location | RER — Extrapolated from data of a plant in Switzerland, assumed valid for Europe (RER). | | Time period | 1990-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control: 0 failed, 1 warning(s) (Section 7) | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module summarises infrastructure components of a cogeneration unit. ; UUID: a417512e-3012-33e1-ae0e-18a3165240a5 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Cogen unit 200kWe, components for electricity only (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes all components related exclusively to electricity production. ==== Technology ==== Extrapolated from data of a 160kWe lambda=1 plant, adjusted to lean burn technology currently available on market, no catalytic converters. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electric parts of cogen unit 160kWe | technosphere | RER | 1 | p | none declared: tdc-doc default ±50 % | — | 52.0 | ██████████ | | | Generator 200kWe | technosphere | RER | 1.25 | p | none declared: tdc-doc default ±50 % | — | 35.7 | ███████ | | | Assembly, generator and motor, cogen unit 160kWe | technosphere | RER | 1 | p | none declared: tdc-doc default ±50 % | — | 12.3 | ██ | | ==== Data quality ==== 0 of 3 direct exchanges carry a declared pedigree, 0 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | see Geography/Text, see Technolgy Text | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 3 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **68.99** | 45.85 | 128 | 1.74 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **39.71** | 19.37 | 127.3 | 2.73 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.097e+04** | 8731 | 1.867e+04 | 1.45 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.269** | 2.897 | 8.825 | 1.75 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.102e+04** | 8765 | 1.876e+04 | 1.45 | | EF-particulate Matter | Impact on human health | disease incidence | **3.938e-04** | 3.234e-04 | 7.483e-04 | 1.54 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.861e+04** | 3.264e+04 | 9.969e+04 | 1.79 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1141** | 949.6 | 2387 | 1.63 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.975e+04** | 3.393e+04 | 1.022e+05 | 1.77 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **8.611** | 6.849 | 15.9 | 1.55 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **19.56** | 10 | 130.5 | 3.67 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **87.94** | 67.52 | 157.1 | 1.53 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.333e-06** | 6.959e-06 | 2.922e-05 | 2.08 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.172e-06** | 3.488e-06 | 1.506e-05 | 2.13 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.450e-05** | 1.232e-05 | 3.980e-05 | 1.81 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.908e-04** | 5.826e-04 | 0.002984 | 2.28 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.588e-05** | 2.860e-05 | 1.478e-04 | 2.28 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **9.467e-04** | 6.286e-04 | 0.00307 | 2.24 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **3189** | 984.6 | 2.712e+04 | 5.06 | | Land use | Soil quality index | pt (soil quality index) | **5.013e+04** | 3.928e+04 | 1.001e+05 | 1.62 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **4.091e-04** | 2.895e-04 | 8.972e-04 | 1.76 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **37.44** | 30.31 | 66.95 | 1.5 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.559e+05** | 1.234e+05 | 2.864e+05 | 1.53 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.4135** | 0.2345 | 0.8087 | 1.89 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **699.1** | -3.258e+06 | 1.908e+06 | — | Climate change 1.102e+04 kg CO2 eq per p. Main contributors: Electric parts of cogen unit 160kWe 52 %; Generator 200kWe 36 %; Assembly, generator and motor, cogen unit 160kWe 12 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electric parts of cogen unit 160kWe 52 %; Generator 200kWe 36 %; Assembly, generator and motor, cogen unit 160kWe 12 %. Most sensitive exchanges (Section 6.3): Electric parts of cogen unit 160kWe [RER] (-26.0 / +26.0 %); Generator 200kWe [RER] (-17.9 / +17.9 %); Assembly, generator and motor, cogen unit 160kWe [RER] (-6.1 / +6.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 68.99 | 76.6 | 0.901 | | Climate change-Biogenic | 39.71 | 39.71 | 1.000 | | Climate change-Fossil | 1.097e+04 | 1.097e+04 | 1.000 | | Climate change-Land use and land use change | 4.269 | 4.269 | 1.000 | | Climate change | 1.102e+04 | 1.102e+04 | 1.000 | | EF-particulate Matter | 3.938e-04 | 3.938e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 3.861e+04 | 3.981e+04 | 0.970 | | Ecotoxicity, freshwater_organics | 1141 | 1134 | 1.006 | | Ecotoxicity, freshwater | 3.975e+04 | 4.09e+04 | 0.972 | | Eutrophication marine | 8.611 | 8.611 | 1.000 | | Eutrophication, freshwater | 19.56 | 19.56 | 1.000 | | Eutrophication, terrestrial | 87.94 | 92.28 | 0.953 | | Human toxicity, cancer_inorganics | 9.333e-06 | 9.269e-06 | 1.007 | | Human toxicity, cancer_organics | 5.172e-06 | 5.172e-06 | 1.000 | | Human toxicity, cancer | 1.450e-05 | 1.444e-05 | 1.004 | | Human toxicity, non-cancer_inorganics | 8.908e-04 | 8.883e-04 | 1.003 | | Human toxicity, non-cancer_organics | 5.588e-05 | 5.588e-05 | 1.000 | | Human toxicity, non-cancer | 9.467e-04 | 9.442e-04 | 1.003 | | Ionising radiation, human health | 3189 | 3189 | 1.000 | | Land use | 5.013e+04 | 4.041e+04 | 1.240 | | Ozone depletion | 4.091e-04 | 4.091e-04 | 1.000 | | Photochemical ozone formation - human health | 37.44 | 37.44 | 1.000 | | Resource use, fossils | 1.559e+05 | 1.560e+05 | 1.000 | | Resource use, minerals and metals | 0.4135 | 0.4128 | 1.002 | | Water use | 699.1 | 782.4 | 0.894 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.102e+04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 2.546e+07 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electric parts of cogen unit 160kWe [RER] | 1 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -26.0 / +26.0 | 38.7 (Climate change-Land use and land use change) | | Generator 200kWe [RER] | 1.25 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -17.9 / +17.9 | 46.4 (Human toxicity, non-cancer_inorganics) | | Assembly, generator and motor, cogen unit 160kWe [RER] | 1 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -6.1 / +6.1 | 10.4 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1.102e+04 kg CO2 eq per p (95 % interval 8765–1.876e+04). Dominant contributors: Electric parts of cogen unit 160kWe 52 %; Generator 200kWe 36 %; Assembly, generator and motor, cogen unit 160kWe 12 %. Most sensitive: Electric parts of cogen unit 160kWe [RER] (-26.0 / +26.0 %); Generator 200kWe [RER] (-17.9 / +17.9 %); Assembly, generator and motor, cogen unit 160kWe [RER] (-6.1 / +6.1 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **WARN** | 0/3 exchanges carry a distribution (0 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.102e+04 in [8765, 1.876e+04] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].