====== Disposal, ventilation system, centralized, average for 2 m3(hm2) — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_centralized_average_for_2_m3_hm2__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, centralized, average for 2 m3(hm2) [CH], per 1 m2. EF v3.1 climate change 0.4736 kg CO2 eq (Monte Carlo 95 % interval 0.4412–0.5474). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 24 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 11 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 8 %; Disposal, ventilation system, various components, m2 5 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, centralized, average for 2 m3(hm2) | | Dataset UUID / graph id | ''%%a837fed7-bcca-44e7-87b1-ceab6d95c579%%'' / ''%%activity:disposal_ventilation_system_centralized_average_for_2_m3_hm2__ch%%'' | | Reference product, unit | Disposal, ventilation system, centralized, average for 2 m3(hm2), 1 m2 | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation system for a building with a specific air flow rate of 2 m3/h per m2 heated gross floor area. The reference value of the inventory is 1 m2 heated gross floor area. The inventory is based on average data of 4 office buildings, 3 schools and 3 residential care homes with a total heated gross floor area of 61719 m2 and a total nominal air flow of 302190 m3/h, specific weight of the components: 5.61 kg/m2, including average components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery and a nominal air flow rate of 5'000-20'000 m3/h per unit. No ground heat exchanger is included.; UUID: a837fed7-bcca-44e7-87b1-ceab6d95c579 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Disposal, ventilation system, centralized, average for 2 m3(hm2) (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 0.038133 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 24.4 | █████ | | | Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger | technosphere | CH | 6.1511e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 10.9 | ██ | | | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger | technosphere | CH | 4.5954e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 8.1 | ██ | | | Disposal, ventilation system, various components, m2 | technosphere | CH | 1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.3 | █ | | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 0.083546 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.4 | █ | | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | technosphere | CH | 6.7156e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.2 | █ | | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger | technosphere | CH | 3.6931e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.1 | █ | | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 0.1157 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.0 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 0.099793 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.9 | █ | | | Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger | technosphere | CH | 3.6276e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.8 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 0.049692 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.5 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 0.077357 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.9 | █ | | | Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger | technosphere | CH | 1.3324e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.5 | · | | | Disposal, ventilation unit 6700 m3/h, w. rotary heat exchanger | technosphere | CH | 2.1883e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.3 | · | | | Disposal, silencer for ventilator unit 13000 m3/h, modular | technosphere | CH | 3.9266e-04 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.1 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 0.029293 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.1 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 0.048431 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.9 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 0.035074 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.4 | · | | | Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer | technosphere | CH | 1.5246e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.2 | · | | | Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 0.019767 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.1 | · | | | Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 0.017045 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.1 | · | | | Disposal, silencer for ventilator unit 6700 m3/h, modular, Device | technosphere | CH | 2.5694e-04 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.0 | · | | | Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger | technosphere | CH | 2.0348e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.8 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 0.014226 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | | | Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer | technosphere | CH | 2.2994e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.6 | · | | | Disposal, silencer for ventilator unit 3500 m3/h, modular | technosphere | CH | 1.4722e-04 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | | | Disposal, ventilation unit 3500 m3/h, w. circuit connected heat exchanger | technosphere | CH | 6.1795e-06 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | | | Disposal, thermal insulation, 60mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 0.0072389 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.5mm | technosphere | CH | 0.0052899 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Disposal, silencer for ventilator unit 1800 m3/h, modular, Device | technosphere | CH | 6.4450e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.1 | · | | | Disposal, thermal insulation, 100mm, 40kg/m3, alumium cladding | technosphere | CH | 0.0070241 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, thermal insulation, 100mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 0.0022137 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm | technosphere | CH | 0.0012418 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation duct, stainless steel, s= 1.0mm | technosphere | CH | 0.001794 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation duct, stainless steel, s= 1.25mm | technosphere | CH | 0.0013371 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation duct, stainless steel, s= 1.5mm | technosphere | CH | 9.8826e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, stainless steel, s= 0.87mm | technosphere | CH | 6.8290e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, spiral-seam duct, stainless steel, s= 0.8mm | technosphere | CH | 2.9242e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, stainless steel, s= 0.62mm | technosphere | CH | 4.6666e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation equipment, central, 600-1200 m3/h | technosphere | CH | 2.5856e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | | Disposal, thermal insulation, 30mm, 40kg/m3, stainless steel cladding | technosphere | CH | 0.0018184 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, thermal insulation, 60mm, 40kg/m3, stainless steel cladding | technosphere | CH | 8.2644e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, spiral-seam duct, stainless steel, s= 0.5mm | technosphere | CH | 1.1047e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, stainless steel, s= 0.75mm | technosphere | CH | 9.1357e-05 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 2.1812e-05 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 45 of 45 direct exchanges carry a declared pedigree, 45 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.36 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.124e-04** | 1.026e-04 | 2.220e-04 | 1.47 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.668e-05** | 6.003e-05 | 1.498e-04 | 1.57 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4735** | 0.4412 | 0.5473 | 1.11 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.361e-05** | 1.176e-05 | 2.047e-05 | 1.32 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.4736** | 0.4412 | 0.5474 | 1.11 | | EF-particulate Matter | Impact on human health | disease incidence | **9.262e-09** | 6.087e-09 | 1.892e-08 | 1.79 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.413** | 1.154 | 2.209 | 1.4 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.006193** | 0.005462 | 0.0115 | 1.48 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.42** | 1.163 | 2.217 | 1.39 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.297e-04** | 1.072e-04 | 2.763e-04 | 1.63 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **7.142e-05** | 1.132e-05 | 0.00202 | 15.2 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **9.291e-04** | 7.515e-04 | 0.002179 | 1.72 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.016e-11** | 2.050e-11 | 7.857e-11 | 1.95 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.472e-12** | 7.429e-12 | 1.281e-11 | 1.32 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.863e-11** | 3.033e-11 | 8.807e-11 | 1.72 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.195e-09** | 1.186e-09 | 4.157e-09 | 1.92 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.852e-11** | 5.350e-11 | 1.040e-10 | 1.4 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.264e-09** | 1.264e-09 | 4.222e-09 | 1.88 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.01278** | 0.004915 | 0.07575 | 4.14 | | Land use | Soil quality index | pt (soil quality index) | **0.5319** | -0.01799 | 1.277 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.485e-09** | 1.358e-09 | 2.380e-09 | 1.32 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **3.596e-04** | 3.033e-04 | 7.714e-04 | 1.59 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.6681** | 0.6187 | 1.083 | 1.31 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **8.821e-08** | 7.612e-08 | 1.717e-07 | 1.52 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.04691** | -5.417 | 2.881 | — | Climate change 0.4736 kg CO2 eq per m2. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 24 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 11 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 8 %; Disposal, ventilation system, various components, m2 5 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 24 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 11 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 8 %; Disposal, ventilation system, various components, m2 5 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 4 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-4.6 / +5.7 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-2.2 / +2.8 %); Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-1.6 / +2.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.124e-04 | 2.437e-04 | 0.461 | | Climate change-Biogenic | 7.668e-05 | 7.668e-05 | 1.000 | | Climate change-Fossil | 0.4735 | 0.4735 | 1.000 | | Climate change-Land use and land use change | 1.361e-05 | 1.361e-05 | 1.000 | | Climate change | 0.4736 | 0.4736 | 1.000 | | EF-particulate Matter | 9.262e-09 | 9.262e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.413 | 1.477 | 0.957 | | Ecotoxicity, freshwater_organics | 0.006193 | 0.006172 | 1.003 | | Ecotoxicity, freshwater | 1.42 | 1.483 | 0.957 | | Eutrophication marine | 1.297e-04 | 1.296e-04 | 1.000 | | Eutrophication, freshwater | 7.142e-05 | 7.142e-05 | 1.000 | | Eutrophication, terrestrial | 9.291e-04 | 0.001179 | 0.788 | | Human toxicity, cancer_inorganics | 2.016e-11 | 2.010e-11 | 1.003 | | Human toxicity, cancer_organics | 8.472e-12 | 8.472e-12 | 1.000 | | Human toxicity, cancer | 2.863e-11 | 2.857e-11 | 1.002 | | Human toxicity, non-cancer_inorganics | 1.195e-09 | 1.187e-09 | 1.007 | | Human toxicity, non-cancer_organics | 6.852e-11 | 6.852e-11 | 1.000 | | Human toxicity, non-cancer | 1.264e-09 | 1.256e-09 | 1.006 | | Ionising radiation, human health | 0.01278 | 0.01278 | 1.000 | | Land use | 0.5319 | 0.3106 | 1.712 | | Ozone depletion | 1.485e-09 | 1.485e-09 | 1.000 | | Photochemical ozone formation - human health | 3.596e-04 | 3.596e-04 | 1.000 | | Resource use, fossils | 0.6681 | 0.6681 | 1.000 | | Resource use, minerals and metals | 8.821e-08 | 7.552e-08 | 1.168 | | Water use | 0.04691 | 0.0473 | 0.992 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.4736 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 825.3 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 0.03813 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -4.6 / +5.7 | 5.7 (Climate change-Fossil) | | Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] | 6.151e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -2.2 / +2.8 | 6.0 (Water use) | | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] | 4.595e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.6 / +2.1 | 4.5 (Water use) | | Disposal, ventilation system, various components, m2 [CH] | 1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.0 / +1.3 | 3.1 (Ionising radiation, human health) | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] | 6.716e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.9 / +1.1 | 1.9 (Water use) | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 0.08355 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 11.9 (Eutrophication, freshwater) | | Disposal, ventilation unit 6700 m3/h, w. cross plate heat excanger [CH] | 3.693e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.8 / +1.0 | 2.0 (Water use) | | Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] | 3.628e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.8 / +1.0 | 1.9 (Water use) | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 0.1157 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +0.9 | 3.3 (Eutrophication, freshwater) | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 0.09979 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.9 | 2.8 (Ionising radiation, human health) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 0.04969 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.7 / +0.8 | 0.8 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 0.07736 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.7 | 1.8 (Ionising radiation, human health) | | Disposal, ventilation unit 13000 m3/h, w. cross plate heat excanger [CH] | 1.332e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 1.3 (Water use) | | Disposal, ventilation unit 6700 m3/h, w. rotary heat exchanger [CH] | 2.188e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 1.1 (Water use) | | Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] | 3.927e-04 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.4 / +0.5 | 1.4 (Eutrophication marine) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.4736 kg CO2 eq per m2 (95 % interval 0.4412–0.5474). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 24 %; Disposal, ventilation unit 13000 m3/h, w. circuit connected … 11 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 8 %; Disposal, ventilation system, various components, m2 5 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 4 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-4.6 / +5.7 %); Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-2.2 / +2.8 %); Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-1.6 / +2.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 5.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 45/45 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.4736 in [0.4412, 0.5474] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].