====== Stack PEM fuel cell 2kWe, future — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:stack_pem_fuel_cell_2kwe_future__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Stack PEM fuel cell 2kWe, future [CH], per 1 p. EF v3.1 climate change 92.32 kg CO2 eq (Monte Carlo 95 % interval 79.23–124.4). Main contributors: Disposal, plastic, industr. electronics, 15.3% water, to mun… 44 %; Platinum, at regional storage 17 %; Tetrafluoroethylene, at plant 10 %; Electricity, medium voltage, production ENTSO-E, at grid 10 %; Phenolic resin, at plant 9 %; Natural gas, burned in industrial furnace 1MWth 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Stack PEM fuel cell 2kWe, future | | Dataset UUID / graph id | ''%%adb4d51d-f728-3832-a6d5-d0fa83f1c046%%'' / ''%%activity:stack_pem_fuel_cell_2kwe_future__ch%%'' | | Reference product, unit | Stack PEM fuel cell 2kWe, future, 1 p | | Location | CH | | Time period | 2000-01/2005-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module reflects a polymer electrolyte membrane (PEM) fuel cell stack with 2 kW electrical output. Inventory based on information from literature for future production based on manufacturer data. Life time operation is 6 years or 32'000 h.; Synonyms: PEMFC, proton exchange membrane fuel cell, PEFC, polymer electrolyte fuel cell, Polymer Elektrolyt Membran Brennstoffzelle, Membran Brennstoffzelle; UUID: adb4d51d-f728-3832-a6d5-d0fa83f1c046 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Stack PEM fuel cell 2kWe, future (CH). All results are given per unit of the reference flow. ==== System boundary ==== The module includes the most important materials used for production. Also included is the transport of these materials and the energy needed for production. ==== Technology ==== polymer electrolyte membrane (PEM) fuel cell stack for stationary cogeneration. Performance, stack lifetime and catalyst use according to expected future values for serial production. Electrical efficiency 32%, total efficiency 87%. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, plastic, industr. electronics, 15.3% water, to municipal incineration | technosphere | CH | 13.216 | kg | lognormal, GSD² 1.64 | (4,4,2,2,4,5) | 43.8 | █████████ | | | Platinum, at regional storage | technosphere | RER | 0.0015 | kg | lognormal, GSD² 1.33 | (2,4,2,2,3,5) | 16.8 | ███ | | | Tetrafluoroethylene, at plant | technosphere | RER | 0.104 | kg | lognormal, GSD² 1.33 | (2,4,2,2,3,5) | 10.2 | ██ | | | Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 33.8 | kWh | lognormal, GSD² 1.33 | (2,4,1,2,3,5) | 10.0 | ██ | | | Phenolic resin, at plant | technosphere | RER | 2.2 | kg | lognormal, GSD² 1.35 | (3,4,2,2,3,5) | 9.3 | ██ | | | Natural gas, burned in industrial furnace 1MWth | technosphere | CH | 47 | MJ | lognormal, GSD² 1.33 | (2,4,1,2,3,5) | 3.9 | █ | | | Aluminium, production mix, wrought alloy, at plant | technosphere | RER | 0.6 | kg | lognormal, GSD² 1.33 | (2,4,2,2,3,5) | 3.2 | █ | | | Chromium steel 18/8, at plant | technosphere | RER | 0.2 | kg | lognormal, GSD² 1.33 | (2,4,2,2,3,5) | 1.0 | · | | | Glass fibre, at plant | technosphere | RER | 0.2 | kg | lognormal, GSD² 1.33 | (2,4,2,2,3,5) | 0.5 | · | | | Building, multi-storey | technosphere | RER | 0.0026 | m3 | lognormal, GSD² 3.34 | (4,4,2,5,4,5) | 0.5 | · | | | Disposal, polyvinylfluoride, 0.2% water, to municipal incineration | technosphere | CH | 0.104 | kg | lognormal, GSD² 1.33 | (2,4,2,2,3,5) | 0.3 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 1.2 | tkm | lognormal, GSD² 2.1 | — | 0.2 | · | | | Graphite, at plant | technosphere | RER | 9 | kg | lognormal, GSD² 1.35 | (3,4,2,2,3,5) | 0.2 | · | | | Building, hall, steel construction | technosphere | CH | 4.4000e-04 | m2 | lognormal, GSD² 3.34 | (4,4,2,5,4,5) | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 2.5 | tkm | lognormal, GSD² 2.1 | — | 0.0 | · | | | Isopropanol, at plant | technosphere | RER | 0.019 | kg | lognormal, GSD² 1.35 | (3,4,2,2,3,5) | 0.0 | · | | | Carbon black, at plant | technosphere | GLO | 0.0016 | kg | lognormal, GSD² 2.11 | (4,4,2,2,5,5) | 0.0 | · | | | Water, deionised, at plant | technosphere | CH | 0.012 | kg | lognormal, GSD² 1.35 | (3,4,2,2,3,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 121.68 | MJ | lognormal, GSD² 1.58 | (2,4,1,2,4,5) | 0.0 | · | | | To industrial area | elementary | natural resource | 0.0016 | m2 | lognormal, GSD² 2.35 | (4,4,2,2,5,5) | 0.0 | · | | | N-propanol | elementary | air/Ground level / Urban (>1000 people/s… | 0.019 | kg | lognormal, GSD² 1.69 | (4,4,2,2,3,5) | 0.0 | · | | | From unspecified | elementary | natural resource | 0.0016 | m2 | lognormal, GSD² 2.35 | (4,4,2,2,5,5) | 0.0 | · | | | Industrial area, CH | elementary | natural resource [CH] | 0.079 | m2.a | lognormal, GSD² 1.9 | (4,4,2,5,4,5) | 0.0 | · | | ==== Data quality ==== 21 of 23 direct exchanges carry a declared pedigree, 23 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.95 · completeness 4.0 · temporal 1.86 · geographical 2.43 · technological 3.52 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | Literature data and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.5256** | 0.4029 | 0.7568 | 1.38 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.3359** | 0.2023 | 0.8224 | 2.04 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **91.96** | 78.84 | 124.1 | 1.27 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01851** | 0.01613 | 0.02699 | 1.31 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **92.32** | 79.23 | 124.4 | 1.27 | | EF-particulate Matter | Impact on human health | disease incidence | **5.351e-06** | 4.024e-06 | 8.109e-06 | 1.42 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **878** | 662.6 | 2664 | 2.1 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **114.8** | 61.12 | 307.6 | 2.31 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **992.8** | 772.3 | 2795 | 1.97 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.03902** | 0.03518 | 0.07379 | 1.47 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.09685** | 0.06006 | 0.5761 | 3.15 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.2786** | 0.2491 | 0.5034 | 1.46 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.882e-08** | 3.644e-08 | 5.129e-07 | 4.01 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.184e-08** | 3.958e-08 | 8.301e-08 | 1.46 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.307e-07** | 8.832e-08 | 5.866e-07 | 2.7 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.711e-06** | 1.661e-06 | 1.357e-05 | 2.98 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.207e-06** | 5.721e-07 | 2.855e-06 | 2.34 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.918e-06** | 2.627e-06 | 1.510e-05 | 2.47 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **27.2** | 9.296 | 164.7 | 4.33 | | Land use | Soil quality index | pt (soil quality index) | **338.4** | 288.4 | 563.5 | 1.42 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.678e-04** | 1.492e-04 | 5.125e-04 | 1.89 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.4822** | 0.377 | 0.7151 | 1.4 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **916.1** | 818 | 1314 | 1.28 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.003728** | 0.002872 | 0.005218 | 1.35 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **6.833** | -1.668e+04 | 8414 | — | Climate change 92.32 kg CO2 eq per p. Main contributors: Disposal, plastic, industr. electronics, 15.3% water, to mun… 44 %; Platinum, at regional storage 17 %; Tetrafluoroethylene, at plant 10 %; Electricity, medium voltage, production ENTSO-E, at grid 10 %; Phenolic resin, at plant 9 %; Natural gas, burned in industrial furnace 1MWth 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, plastic, industr. electronics, 15.3% water, to mun… 44 %; Platinum, at regional storage 17 %; Tetrafluoroethylene, at plant 10 %; Electricity, medium voltage, production ENTSO-E, at grid 10 %; Phenolic resin, at plant 9 %; Natural gas, burned in industrial furnace 1MWth 4 %. Most sensitive exchanges (Section 6.3): Disposal, plastic, industr. electronics, 15.3% water, to municipal incineration [CH] (-16.8 / +27.2 %); Platinum, at regional storage [RER] (-4.1 / +5.4 %); Tetrafluoroethylene, at plant [RER] (-2.5 / +3.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.5256 | 5.57 | 0.094 | | Climate change-Biogenic | 0.3359 | 0.3359 | 1.000 | | Climate change-Fossil | 91.96 | 91.99 | 1.000 | | Climate change-Land use and land use change | 0.01851 | 0.01851 | 1.000 | | Climate change | 92.32 | 92.34 | 1.000 | | EF-particulate Matter | 5.351e-06 | 5.351e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 878 | 1126 | 0.780 | | Ecotoxicity, freshwater_organics | 114.8 | 114.8 | 1.001 | | Ecotoxicity, freshwater | 992.8 | 1220 | 0.814 | | Eutrophication marine | 0.03902 | 0.03902 | 1.000 | | Eutrophication, freshwater | 0.09685 | 0.09685 | 1.000 | | Eutrophication, terrestrial | 0.2786 | 0.3306 | 0.843 | | Human toxicity, cancer_inorganics | 7.882e-08 | 7.832e-08 | 1.006 | | Human toxicity, cancer_organics | 5.184e-08 | 5.184e-08 | 1.000 | | Human toxicity, cancer | 1.307e-07 | 1.302e-07 | 1.004 | | Human toxicity, non-cancer_inorganics | 2.711e-06 | 2.661e-06 | 1.019 | | Human toxicity, non-cancer_organics | 1.207e-06 | 1.207e-06 | 1.000 | | Human toxicity, non-cancer | 3.918e-06 | 3.868e-06 | 1.013 | | Ionising radiation, human health | 27.2 | 27.2 | 1.000 | | Land use | 338.4 | 259.1 | 1.306 | | Ozone depletion | 2.678e-04 | 2.678e-04 | 1.000 | | Photochemical ozone formation - human health | 0.4822 | 0.4822 | 1.000 | | Resource use, fossils | 916.1 | 916.7 | 0.999 | | Resource use, minerals and metals | 0.003728 | 0.003652 | 1.021 | | Water use | 6.833 | 7.906 | 0.864 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 92.31 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 4.254e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, plastic, industr. electronics, 15.3% water, to municipal incineration [CH] | 13.22 kg | ×0.617 / ×1.62 | lognormal, GSD² 1.64 | -16.8 / +27.2 | 28.3 (Ecotoxicity, freshwater_inorganics) | | Platinum, at regional storage [RER] | 0.0015 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -4.1 / +5.4 | 31.5 (Human toxicity, non-cancer_organics) | | Tetrafluoroethylene, at plant [RER] | 0.104 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -2.5 / +3.3 | 32.1 (Ozone depletion) | | Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 33.8 kWh | ×0.757 / ×1.32 | lognormal, GSD² 1.33 | -2.4 / +3.2 | 15.0 (Climate change-Biogenic) | | Phenolic resin, at plant [RER] | 2.2 kg | ×0.748 / ×1.34 | lognormal, GSD² 1.35 | -2.3 / +3.1 | 32.7 (Ecotoxicity, freshwater_organics) | | Natural gas, burned in industrial furnace 1MWth [CH] | 47 MJ | ×0.757 / ×1.32 | lognormal, GSD² 1.33 | -0.9 / +1.2 | 2.0 (Resource use, fossils) | | Aluminium, production mix, wrought alloy, at plant [RER] | 0.6 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -0.8 / +1.0 | 7.1 (Climate change-Land use and land use change) | | Building, multi-storey [RER] | 0.0026 m3 | ×0.306 / ×3.26 | lognormal, GSD² 3.34 | -0.3 / +1.0 | 16.4 (Land use) | | Chromium steel 18/8, at plant [RER] | 0.2 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -0.2 / +0.3 | 0.9 (Eutrophication, terrestrial) | | Building, hall, steel construction [CH] | 4.400e-04 m2 | ×0.306 / ×3.26 | lognormal, GSD² 3.34 | -0.1 / +0.3 | 3.7 (Eutrophication, terrestrial) | | Transport, freight, lorry, fleet average [RER] | 1.2 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.1 / +0.3 | 5.0 (Climate change-Land use and land use change) | | Glass fibre, at plant [RER] | 0.2 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -0.1 / +0.2 | 0.6 (Eutrophication, terrestrial) | | Disposal, polyvinylfluoride, 0.2% water, to municipal incineration [CH] | 0.104 kg | ×0.756 / ×1.32 | lognormal, GSD² 1.33 | -0.1 / +0.1 | 0.2 (Water use) | | Graphite, at plant [RER] | 9 kg | ×0.748 / ×1.34 | lognormal, GSD² 1.35 | -0.1 / +0.1 | 0.3 (Eutrophication, terrestrial) | | Transport, freight, rail [RER] | 2.5 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.0 | 0.4 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 92.32 kg CO2 eq per p (95 % interval 79.23–124.4). Dominant contributors: Disposal, plastic, industr. electronics, 15.3% water, to mun… 44 %; Platinum, at regional storage 17 %; Tetrafluoroethylene, at plant 10 %; Electricity, medium voltage, production ENTSO-E, at grid 10 %; Phenolic resin, at plant 9 %; Natural gas, burned in industrial furnace 1MWth 4 %. Most sensitive: Disposal, plastic, industr. electronics, 15.3% water, to municipal incineration [CH] (-16.8 / +27.2 %); Platinum, at regional storage [RER] (-4.1 / +5.4 %); Tetrafluoroethylene, at plant [RER] (-2.5 / +3.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.3e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 0.9997; categories within ±5 %: 19/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 23/23 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 92.32 in [79.23, 124.4] | | time period declared | **PASS** | 2000-01/2005-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Primas A., 0 (2007) Life Cycle Inventories of new CHP systems. Final report ecoinvent Data v2.0. Editors: 0. Volume: 20. Swiss Centre for LCI, B&H AG. Duebendorf and Zurich, CH. Type: Measurement on site Source: CD-ROM First author: Primas A. Other authors: 0 Year: 2007 Name of editors: 0 Title of anthology: Final report ecoinvent Data v2.0 Place of publication: Duebendorf and Zurich, CH Publisher… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].