====== Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_unit_3500_m3_h_w_cross_plate_heat_excanger__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH], per 1 p. EF v3.1 climate change 298.1 kg CO2 eq (Monte Carlo 95 % interval 260.9–383.8). Main contributors: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 43 %; Disposal, building, polyurethane foam, to final disposal 35 %; Disposal, control and wiring, central unit 14 %; Disposal, building, polyethylene/polypropylene products, to … 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 3 %; Disposal, building, bulk iron (excluding reinforcement), to … 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | | Dataset UUID / graph id | ''%%afef64c2-e7d5-425d-b533-b4b5a6c0e734%%'' / ''%%activity:disposal_ventilation_unit_3500_m3_h_w_cross_plate_heat_excanger__ch%%'' | | Reference product, unit | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation unit (air handling unit) with 3500 m3/h nominal air flow rate (at 2 m/s air speed in cross section of air filter or heat exchanger), component weight: 1145 kg, total weight: 1344 kg/Unit, including average components for controls, inverter and electric control cabinet, material for 20 filter replacements (once a year for 20 years lifetime). The air handling unit includes a frame construction, two radial belt drive fans, two multi-leaf damper, heat recovery with aluminium plate heat exchanger, heating elements, expansion plenum and empty section in supply and extract air. No cooling elements, humidifier, air-mixing plenum and silencer included. The frame construction made of aluminium-profiles, casing made of hot-dip galvanized and powder coated steel sheets insulated with polyurethane foam.; UUID: afef64c2-e7d5-425d-b533-b4b5a6c0e734 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration | technosphere | CH | 61.152 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 42.5 | █████████ | | | Disposal, building, polyurethane foam, to final disposal | technosphere | CH | 38.182 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 35.1 | ███████ | | | Disposal, control and wiring, central unit | technosphere | CH | 9.5 | p | lognormal, GSD² 1.34 | (3,4,1,1,3,5) | 14.0 | ███ | | | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 3.495 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.6 | █ | | | Disposal, rubber, unspecified, 0% water, to municipal incineration | technosphere | CH | 3.0684 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.3 | █ | | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant | technosphere | CH | 1206.5 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.4 | · | | | Disposal, wood untreated, 20% water, to municipal incineration | technosphere | CH | 30.576 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 0.91728 | tkm | lognormal, GSD² 2.14 | (4,5,1,1,1,5) | 0.1 | · | | | Disposal, building, paint on metal, to sorting plant | technosphere | CH | 35.514 | kg | lognormal, GSD² 1.32 | (4,4,1,1,1,5) | 0.0 | · | | | Disposal, glass, 0% water, to municipal incineration | technosphere | CH | 1.4978 | kg | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 10 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.8 · completeness 4.1 · temporal 1.0 · geographical 1.0 · technological 1.2 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.06193** | 0.04232 | 0.2119 | 2.24 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02854** | 0.02146 | 0.07515 | 1.9 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **298.1** | 260.8 | 383.8 | 1.23 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004685** | 0.003816 | 0.009283 | 1.58 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **298.1** | 260.9 | 383.8 | 1.23 | | EF-particulate Matter | Impact on human health | disease incidence | **7.026e-07** | 6.005e-07 | 1.827e-06 | 1.72 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1543** | 1113 | 2559 | 1.52 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.842** | 1.547 | 5.249 | 1.85 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1544** | 1115 | 2563 | 1.52 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.1009** | 0.0642 | 0.3154 | 2.25 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.00221** | 0.001861 | 0.01692 | 3.22 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.5998** | 0.3184 | 2.389 | 2.81 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.784e-08** | 1.542e-08 | 8.427e-08 | 2.34 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.055e-09** | 1.955e-09 | 4.945e-09 | 1.61 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.990e-08** | 1.788e-08 | 8.660e-08 | 2.2 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.083e-06** | 9.505e-07 | 4.411e-06 | 2.25 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.407e-09** | 7.463e-09 | 1.850e-08 | 1.58 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.091e-06** | 9.592e-07 | 4.421e-06 | 2.24 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **3.824** | 1.521 | 24.99 | 4.25 | | Land use | Soil quality index | pt (soil quality index) | **111.6** | 100.1 | 171.5 | 1.32 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **5.893e-07** | 4.916e-07 | 1.640e-06 | 1.81 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.2025** | 0.1169 | 0.7644 | 2.61 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **243.7** | 189.6 | 813.6 | 2.03 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.647e-05** | 3.106e-05 | 8.530e-05 | 1.68 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **51.4** | -1916 | 1091 | — | Climate change 298.1 kg CO2 eq per p. Main contributors: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 43 %; Disposal, building, polyurethane foam, to final disposal 35 %; Disposal, control and wiring, central unit 14 %; Disposal, building, polyethylene/polypropylene products, to … 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 3 %; Disposal, building, bulk iron (excluding reinforcement), to … 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 43 %; Disposal, building, polyurethane foam, to final disposal 35 %; Disposal, control and wiring, central unit 14 %; Disposal, building, polyethylene/polypropylene products, to … 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 3 %; Disposal, building, bulk iron (excluding reinforcement), to … 1 %. Most sensitive exchanges (Section 6.3): Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration [CH] (-8.1 / +10.0 %); Disposal, building, polyurethane foam, to final disposal [CH] (-6.7 / +8.2 %); Disposal, control and wiring, central unit [CH] (-3.5 / +4.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.06193 | 0.1492 | 0.415 | | Climate change-Biogenic | 0.02854 | 0.02854 | 1.000 | | Climate change-Fossil | 298.1 | 298.1 | 1.000 | | Climate change-Land use and land use change | 0.004685 | 0.004685 | 1.000 | | Climate change | 298.1 | 298.1 | 1.000 | | EF-particulate Matter | 7.026e-07 | 7.026e-07 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1543 | 1622 | 0.951 | | Ecotoxicity, freshwater_organics | 1.842 | 1.835 | 1.004 | | Ecotoxicity, freshwater | 1544 | 1624 | 0.951 | | Eutrophication marine | 0.1009 | 0.1009 | 1.000 | | Eutrophication, freshwater | 0.00221 | 0.00221 | 1.000 | | Eutrophication, terrestrial | 0.5998 | 0.7697 | 0.779 | | Human toxicity, cancer_inorganics | 1.784e-08 | 1.782e-08 | 1.002 | | Human toxicity, cancer_organics | 2.055e-09 | 2.055e-09 | 1.000 | | Human toxicity, cancer | 1.990e-08 | 1.987e-08 | 1.001 | | Human toxicity, non-cancer_inorganics | 1.083e-06 | 1.078e-06 | 1.004 | | Human toxicity, non-cancer_organics | 8.407e-09 | 8.406e-09 | 1.000 | | Human toxicity, non-cancer | 1.091e-06 | 1.087e-06 | 1.004 | | Ionising radiation, human health | 3.824 | 3.824 | 1.000 | | Land use | 111.6 | 75.18 | 1.485 | | Ozone depletion | 5.893e-07 | 5.893e-07 | 1.000 | | Photochemical ozone formation - human health | 0.2025 | 0.2025 | 1.000 | | Resource use, fossils | 243.7 | 243.7 | 1.000 | | Resource use, minerals and metals | 3.647e-05 | 2.468e-05 | 1.478 | | Water use | 51.4 | 51.48 | 0.998 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 298.1 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 3.200e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration [CH] | 61.15 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -8.1 / +10.0 | 10.0 (Climate change-Fossil) | | Disposal, building, polyurethane foam, to final disposal [CH] | 38.18 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -6.7 / +8.2 | 16.0 (Eutrophication marine) | | Disposal, control and wiring, central unit [CH] | 9.5 p | ×0.751 / ×1.33 | lognormal, GSD² 1.34 | -3.5 / +4.6 | 26.4 (Water use) | | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 3.495 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 0.9 (Climate change-Fossil) | | Disposal, rubber, unspecified, 0% water, to municipal incineration [CH] | 3.068 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.8 | 0.8 (Climate change-Fossil) | | Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] | 1206 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.3 / +0.3 | 14.3 (Ionising radiation, human health) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 0.9173 tkm | ×0.474 / ×2.11 | lognormal, GSD² 2.14 | -0.0 / +0.1 | 1.9 (Ecotoxicity, freshwater_organics) | | Disposal, wood untreated, 20% water, to municipal incineration [CH] | 30.58 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 2.0 (Eutrophication, freshwater) | | Disposal, building, paint on metal, to sorting plant [CH] | 35.51 kg | ×0.762 / ×1.31 | lognormal, GSD² 1.32 | -0.0 / +0.0 | 0.7 (Human toxicity, non-cancer_organics) | | Disposal, glass, 0% water, to municipal incineration [CH] | 1.498 kg | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.3 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 298.1 kg CO2 eq per p (95 % interval 260.9–383.8). Dominant contributors: Disposal, polyethylene terephtalate, 0.2% water, to municipa… 43 %; Disposal, building, polyurethane foam, to final disposal 35 %; Disposal, control and wiring, central unit 14 %; Disposal, building, polyethylene/polypropylene products, to … 4 %; Disposal, rubber, unspecified, 0% water, to municipal incine… 3 %; Disposal, building, bulk iron (excluding reinforcement), to … 1 %. Most sensitive: Disposal, polyethylene terephtalate, 0.2% water, to municipal incineration [CH] (-8.1 / +10.0 %); Disposal, building, polyurethane foam, to final disposal [CH] (-6.7 / +8.2 %); Disposal, control and wiring, central unit [CH] (-3.5 / +4.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 298.1 in [260.9, 383.8] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].