====== 324 kWp flat-roof installation, multi-Si, on roof — DE ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:324_kwp_flat_roof_installation_multi_si_on_roof__de|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 324 kWp flat-roof installation, multi-Si, on roof [DE], per 1 p. EF v3.1 climate change 2.737e+05 kg CO2 eq (Monte Carlo 95 % interval 1.212e+05–1.435e+06). Main contributors: Photovoltaic panel, multi-Si, at regional storage 71 %; Flat roof construction, on roof 17 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 324 kWp photovoltaic plant, at plant 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 324 kWp flat-roof installation, multi-Si, on roof | | Dataset UUID / graph id | ''%%b3cbd595-90a9-3747-8c78-bc5ad4de623b%%'' / ''%%activity:324_kwp_flat_roof_installation_multi_si_on_roof__de%%'' | | Reference product, unit | 324 kWp flat-roof installation, multi-Si, on roof, 1 p | | Location | DE — Installation in DE | | Time period | 2004-01/2018-12 | | Category | electricity by fuel / photovoltaic\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 324kWp and a life time of 30 years installed in Germany. The efficiency of multi-Si PV modules is 16.8% (Fraunhofer ISE Photovoltaics Report 2019). The share of rejected or replaced PV modules is estimated at 3%. The inverter is assumed to be replaced once during the service life of the PV system.; Synonyms: monocrystalline, single crystalline, silicon; UUID: b3cbd595-90a9-3747-8c78-bc5ad4de623b This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 324 kWp flat-roof installation, multi-Si, on roof (DE). All results are given per unit of the reference flow. ==== System boundary ==== All components (modules, mounting system, electric installation, inverter) for the installation of a 324 kWp photovoltaic plant, energy use for the mounting, transport of materials to the place of installation. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic panel, multi-Si, at regional storage | technosphere | RER | 1854 | m2 | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 71.2 | ██████████████ | | | Flat roof construction, on roof | technosphere | RER | 1800 | m2 | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 17.0 | ███ | | | Inverter, 500kW, at plant | technosphere | RER | 1.7385 | p | lognormal, GSD² 4.47 | (2,4,1,1,1,5) | 7.8 | ██ | | | Treatment, c-Si PV module | technosphere | RER | 24463 | kg | lognormal, GSD² 2.77 | (3,4,1,1,1,5) | 2.5 | · | | | Electric installation, 324 kWp photovoltaic plant, at plant | technosphere | DE | 1 | p | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 1.3 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 3909 | tkm | lognormal, GSD² 2.99 | — | 0.3 | · | | | Electricity, low voltage, at grid | technosphere | DE | 24.84 | kWh | lognormal, GSD² 2.77 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 89.424 | MJ | lognormal, GSD² 2.06 | — | 0.0 | · | | ==== Data quality ==== 6 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.83 · completeness 4.0 · temporal 1.33 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | Publication of plant specific (partly aggregated) data and literature information. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1116** | 554.9 | 5537 | 3.35 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1206** | 355 | 9119 | 5.46 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.723e+05** | 1.208e+05 | 1.426e+06 | 3.64 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **196.5** | 96.47 | 836.6 | 3 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.737e+05** | 1.212e+05 | 1.435e+06 | 3.64 | | EF-particulate Matter | Impact on human health | disease incidence | **0.009519** | 0.004857 | 0.08868 | 4.34 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.495e+06** | 6.418e+05 | 1.044e+07 | 4.23 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.05e+04** | 1.661e+04 | 1.872e+05 | 3.47 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.525e+06** | 6.620e+05 | 1.058e+07 | 4.2 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **303.6** | 132.3 | 1775 | 3.87 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **134.6** | 73.84 | 1302 | 4.29 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2319** | 1081 | 1.265e+04 | 3.66 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.521e-05** | 6.012e-05 | 7.580e-04 | 3.59 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.761e-05** | 2.916e-05 | 4.300e-04 | 4.1 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.628e-04** | 9.373e-05 | 0.001116 | 3.59 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.005266** | 0.003558 | 0.0389 | 3.29 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.014e-04** | 1.561e-04 | 0.001285 | 2.98 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.005568** | 0.003766 | 0.03988 | 3.25 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **6.814e+04** | 1.885e+04 | 8.269e+05 | 7.55 | | Land use | Soil quality index | pt (soil quality index) | **1.841e+06** | 7.457e+05 | 1.177e+07 | 4.33 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.00791** | 0.003376 | 0.04957 | 4.08 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **789.9** | 401.3 | 4143 | 3.44 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3.666e+06** | 1.713e+06 | 1.980e+07 | 3.67 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **9.767** | 3.189 | 57.65 | 4.44 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **9.049e+04** | -1.231e+08 | 7.003e+07 | — | Climate change 2.737e+05 kg CO2 eq per p. Main contributors: Photovoltaic panel, multi-Si, at regional storage 71 %; Flat roof construction, on roof 17 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 324 kWp photovoltaic plant, at plant 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic panel, multi-Si, at regional storage 71 %; Flat roof construction, on roof 17 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 324 kWp photovoltaic plant, at plant 1 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel, multi-Si, at regional storage [RER] (-54.7 / +237.3 %); Flat roof construction, on roof [RER] (-13.1 / +56.8 %); Inverter, 500kW, at plant [RER] (-6.0 / +26.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1116 | 1162 | 0.960 | | Climate change-Biogenic | 1206 | 1206 | 1.000 | | Climate change-Fossil | 2.723e+05 | 2.723e+05 | 1.000 | | Climate change-Land use and land use change | 196.5 | 196.5 | 1.000 | | Climate change | 2.737e+05 | 2.737e+05 | 1.000 | | EF-particulate Matter | 0.009519 | 0.009519 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.495e+06 | 1.525e+06 | 0.980 | | Ecotoxicity, freshwater_organics | 3.05e+04 | 2.573e+04 | 1.186 | | Ecotoxicity, freshwater | 1.525e+06 | 1.550e+06 | 0.984 | | Eutrophication marine | 303.6 | 303.6 | 1.000 | | Eutrophication, freshwater | 134.6 | 134.6 | 1.000 | | Eutrophication, terrestrial | 2319 | 2402 | 0.965 | | Human toxicity, cancer_inorganics | 9.521e-05 | 9.466e-05 | 1.006 | | Human toxicity, cancer_organics | 6.761e-05 | 6.760e-05 | 1.000 | | Human toxicity, cancer | 1.628e-04 | 1.623e-04 | 1.003 | | Human toxicity, non-cancer_inorganics | 0.005266 | 0.005242 | 1.005 | | Human toxicity, non-cancer_organics | 3.014e-04 | 3.011e-04 | 1.001 | | Human toxicity, non-cancer | 0.005568 | 0.005543 | 1.004 | | Ionising radiation, human health | 6.814e+04 | 6.814e+04 | 1.000 | | Land use | 1.841e+06 | 1.486e+06 | 1.238 | | Ozone depletion | 0.00791 | 0.00791 | 1.000 | | Photochemical ozone formation - human health | 789.9 | 789.9 | 1.000 | | Resource use, fossils | 3.666e+06 | 3.667e+06 | 1.000 | | Resource use, minerals and metals | 9.767 | 9.622 | 1.015 | | Water use | 9.049e+04 | 9.09e+04 | 0.995 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2.733e+05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 5.469e+08 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic panel, multi-Si, at regional storage [RER] | 1854 m2 | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -54.7 / +237.3 | 311.7 (Water use) | | Flat roof construction, on roof [RER] | 1800 m2 | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -13.1 / +56.8 | 79.0 (Human toxicity, cancer_inorganics) | | Inverter, 500kW, at plant [RER] | 1.738 p | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -6.0 / +26.0 | 129.1 (Human toxicity, non-cancer_organics) | | Treatment, c-Si PV module [RER] | 2.446e+04 kg | ×0.369 / ×2.71 | lognormal, GSD² 2.77 | -1.6 / +4.2 | 6.9 (Climate change-Land use and land use change) | | Electric installation, 324 kWp photovoltaic plant, at plant [DE] | 1 p | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -1.0 / +4.3 | 69.6 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, fleet average [RER] | 3909 tkm | ×0.342 / ×2.92 | lognormal, GSD² 2.99 | -0.2 / +0.5 | 2.8 (Climate change-Land use and land use change) | | Electricity, low voltage, at grid [DE] | 24.84 kWh | ×0.369 / ×2.71 | lognormal, GSD² 2.77 | -0.0 / +0.0 | 0.0 (Human toxicity, cancer_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 2.737e+05 kg CO2 eq per p (95 % interval 1.212e+05–1.435e+06). Dominant contributors: Photovoltaic panel, multi-Si, at regional storage 71 %; Flat roof construction, on roof 17 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 2 %; Electric installation, 324 kWp photovoltaic plant, at plant 1 %. Most sensitive: Photovoltaic panel, multi-Si, at regional storage [RER] (-54.7 / +237.3 %); Flat roof construction, on roof [RER] (-13.1 / +56.8 %); Inverter, 500kW, at plant [RER] (-6.0 / +26.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2.737e+05 in [1.212e+05, 1.435e+06] | | time period declared | **PASS** | 2004-01/2018-12 | | geography is a known location code | **PASS** | DE | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].