====== Electricity mix, SBB — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_mix_sbb__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity mix, SBB [CH], per 1 kWh. EF v3.1 climate change 0.005122 kg CO2 eq (Monte Carlo 95 % interval 0.00403–0.009444). Main contributors: Electricity, hydropower, at power plant 67 %; Electricity, hydropower, at power plant 15 %; Electricity, nuclear, at power plant 13 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity mix, SBB | | Dataset UUID / graph id | ''%%baa46904-44f5-324f-b6ea-149b4f96b03a%%'' / ''%%activity:electricity_mix_sbb__ch%%'' | | Reference product, unit | Electricity mix, SBB, 1 kWh | | Location | CH — Switzerland | | Time period | 2000-01/2000-12 | | Category | electricity / supply mix | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Technology shares determined based on information from SBB (pers. correspondence).; UUID: baa46904-44f5-324f-b6ea-149b4f96b03a This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity mix, SBB (CH). All results are given per unit of the reference flow. ==== System boundary ==== This dataset includes the shares of different technologies of the SBB production mix in Switzerland in 2014. ==== Technology ==== Average technology ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, hydropower, at power plant | technosphere | CH | 0.75274 | kWh | lognormal, GSD² 1.05 | — | 66.5 | █████████████ | | | Electricity, hydropower, at power plant | technosphere | FR | 0.197 | kWh | lognormal, GSD² 1.05 | — | 15.3 | ███ | | | Electricity, nuclear, at power plant | technosphere | CH | 0.045 | kWh | lognormal, GSD² 1.05 | — | 12.8 | ███ | | | Electricity, at cogen 300kWth, biomethane, allocation exergy | technosphere | CH | 4.3232e-04 | kWh | lognormal, GSD² 1.05 | — | 2.7 | █ | | | Electricity, production mix photovoltaic, at plant | technosphere | CH | 0.00176 | kWh | lognormal, GSD² 1.05 | — | 1.0 | · | | | Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy | technosphere | CH | 2.8124e-04 | kWh | lognormal, GSD² 1.05 | — | 0.8 | · | | | Electricity, at cogen 1MWth, wood chips, allocation exergy | technosphere | CH | 5.8847e-04 | kWh | lognormal, GSD² 1.05 | — | 0.7 | · | | | Electricity, at wind farm | technosphere | CH | 3.3000e-04 | kWh | lognormal, GSD² 1.05 | — | 0.1 | · | | | Electricity from waste, at municipal waste incineration plant | technosphere | CH | 0.001868 | kWh | lognormal, GSD² 1.05 | — | -0.0 | · | | ==== Data quality ==== 0 of 9 direct exchanges carry a declared pedigree, 9 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Luana Krebs (TREEZE); data entry: Luana Krebs (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Some generic datasets from ecoinvent have been used. | | sampling procedure | Statistics | | production volume | GWh | | uncertainty adjustments | | | validation details | Proof reading validation: 02.11.2020; Other validation: G:\Projekte laufend\713 Aktualisierung mobitool 2020\EcoSpold[713-Strommix-Übertragung-Verteilung-Bahnstrom-EIv2-v0.4.xlsx]X-Process; | | time period comment | Time of publications | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.146e-05** | 9.675e-06 | 2.076e-05 | 1.49 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.570e-04** | 2.035e-04 | 3.539e-04 | 1.34 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004238** | 0.003147 | 0.008563 | 1.68 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.268e-04** | 4.378e-04 | 9.114e-04 | 1.46 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.005122** | 0.00403 | 0.009444 | 1.56 | | EF-particulate Matter | Impact on human health | disease incidence | **6.416e-10** | 4.911e-10 | 1.243e-09 | 1.59 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.0104** | 0.009731 | 0.0239 | 1.59 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.911e-04** | 2.510e-04 | 8.561e-04 | 2.13 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01069** | 0.01001 | 0.0252 | 1.59 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **4.833e-06** | 4.104e-06 | 8.484e-06 | 1.47 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.053e-06** | 1.338e-06 | 2.192e-05 | 4.06 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **4.249e-05** | 3.502e-05 | 7.676e-05 | 1.52 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.331e-12** | 1.176e-12 | 4.063e-12 | 1.86 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.578e-12** | 1.178e-12 | 2.849e-12 | 1.58 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.909e-12** | 2.558e-12 | 6.556e-12 | 1.62 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.593e-11** | 6.629e-11 | 2.440e-10 | 1.94 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.608e-12** | 3.302e-12 | 1.057e-11 | 1.83 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **8.054e-11** | 7.063e-11 | 2.545e-10 | 1.92 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.07297** | 0.02757 | 0.3965 | 4.07 | | Land use | Soil quality index | pt (soil quality index) | **0.03392** | -0.002049 | 0.08696 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.270e-09** | 1.890e-09 | 2.776e-09 | 1.22 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.377e-05** | 1.109e-05 | 2.825e-05 | 1.62 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.6434** | 0.5565 | 0.8386 | 1.23 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.896e-08** | 2.246e-08 | 5.970e-08 | 1.68 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.006365** | -455.9 | 231 | — | Climate change 0.005122 kg CO2 eq per kWh. Main contributors: Electricity, hydropower, at power plant 67 %; Electricity, hydropower, at power plant 15 %; Electricity, nuclear, at power plant 13 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, hydropower, at power plant 67 %; Electricity, hydropower, at power plant 15 %; Electricity, nuclear, at power plant 13 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 1 %. Most sensitive exchanges (Section 6.3): Electricity, hydropower, at power plant [CH] (-3.1 / +3.3 %); Electricity, hydropower, at power plant [FR] (-0.7 / +0.8 %); Electricity, nuclear, at power plant [CH] (-0.6 / +0.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.146e-05 | 1.654e-05 | 0.693 | | Climate change-Biogenic | 2.570e-04 | 2.570e-04 | 1.000 | | Climate change-Fossil | 0.004238 | 0.004238 | 1.000 | | Climate change-Land use and land use change | 6.268e-04 | 6.268e-04 | 1.000 | | Climate change | 0.005122 | 0.005122 | 1.000 | | EF-particulate Matter | 6.416e-10 | 6.416e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.0104 | 0.01156 | 0.900 | | Ecotoxicity, freshwater_organics | 2.911e-04 | 2.837e-04 | 1.026 | | Ecotoxicity, freshwater | 0.01069 | 0.01183 | 0.904 | | Eutrophication marine | 4.833e-06 | 4.766e-06 | 1.014 | | Eutrophication, freshwater | 2.053e-06 | 2.053e-06 | 1.000 | | Eutrophication, terrestrial | 4.249e-05 | 4.574e-05 | 0.929 | | Human toxicity, cancer_inorganics | 1.331e-12 | 1.289e-12 | 1.033 | | Human toxicity, cancer_organics | 1.578e-12 | 1.578e-12 | 1.000 | | Human toxicity, cancer | 2.909e-12 | 2.867e-12 | 1.015 | | Human toxicity, non-cancer_inorganics | 7.593e-11 | 7.318e-11 | 1.038 | | Human toxicity, non-cancer_organics | 4.608e-12 | 4.607e-12 | 1.000 | | Human toxicity, non-cancer | 8.054e-11 | 7.779e-11 | 1.035 | | Ionising radiation, human health | 0.07297 | 0.07297 | 1.000 | | Land use | 0.03392 | 0.01439 | 2.357 | | Ozone depletion | 2.270e-09 | 2.270e-09 | 1.000 | | Photochemical ozone formation - human health | 1.377e-05 | 1.377e-05 | 1.000 | | Resource use, fossils | 0.6434 | 0.6434 | 1.000 | | Resource use, minerals and metals | 2.896e-08 | 2.875e-08 | 1.008 | | Water use | 0.006365 | 0.007058 | 0.902 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.005122 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 43.56 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, hydropower, at power plant [CH] | 0.7527 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -3.1 / +3.3 | 4.5 (Climate change-Land use and land use change) | | Electricity, hydropower, at power plant [FR] | 0.197 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.7 / +0.8 | 1.2 (Climate change-Biogenic) | | Electricity, nuclear, at power plant [CH] | 0.045 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.6 / +0.6 | 4.8 (Ionising radiation, human health) | | Electricity, at cogen 300kWth, biomethane, allocation exergy [CH] | 4.323e-04 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.1 / +0.1 | 1.5 (Climate change-Biogenic) | | Electricity, production mix photovoltaic, at plant [CH] | 0.00176 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.8 (Resource use, minerals and metals) | | Electricity, at cogen with biogas engine, agricultural covered, alloc. exergy [CH] | 2.812e-04 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.6 (Eutrophication, terrestrial) | | Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] | 5.885e-04 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 6.7 (Land use) | | Electricity, at wind farm [CH] | 3.300e-04 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | Electricity from waste, at municipal waste incineration plant [CH] | 0.001868 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | +0.0 / -0.0 | 0.0 (Acidification) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.005122 kg CO2 eq per kWh (95 % interval 0.00403–0.009444). Dominant contributors: Electricity, hydropower, at power plant 67 %; Electricity, hydropower, at power plant 15 %; Electricity, nuclear, at power plant 13 %; Electricity, at cogen 300kWth, biomethane, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 1 %. Most sensitive: Electricity, hydropower, at power plant [CH] (-3.1 / +3.3 %); Electricity, hydropower, at power plant [FR] (-0.7 / +0.8 %); Electricity, nuclear, at power plant [CH] (-0.6 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 19/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 9/9 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.005122 in [0.00403, 0.009444] | | time period declared | **PASS** | 2000-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - L. Krebs, R. Frischknecht (2020) Aktualisierung Ökobilanzdaten mobitool 2020, Teil 1. Project report. Volume: 713. treeze Ltd.. Uster, CH. Type: Separate publication Source: Report First author: L. Krebs Other authors: R. Frischknecht Year: 2020 Title of anthology: Project report Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 713 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].