====== Electricity, at Mini CHP plant, allocation heat — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_at_mini_chp_plant_allocation_heat__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, at Mini CHP plant, allocation heat [CH], per 1 kWh. EF v3.1 climate change 0.001341 kg CO2 eq (Monte Carlo 95 % interval 0.001119–0.002058). Main contributors: Mini CHP plant, components for electricity only 100 %. Status: final control: 0 failed, 1 warning(s) (Section 7). ^ Item ^ Value ^ | Dataset name | Electricity, at Mini CHP plant, allocation heat | | Dataset UUID / graph id | ''%%baa5adf6-1695-3aee-a42a-508802b8aac5%%'' / ''%%activity:electricity_at_mini_chp_plant_allocation_heat__ch%%'' | | Reference product, unit | Electricity, at Mini CHP plant, allocation heat, 1 kWh | | Location | CH — Could be used for central European conditions. | | Time period | 2000-01/2000-12 | | Category | electricity by fuel / natural gas\cogeneration | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control: 0 failed, 1 warning(s) (Section 7) | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The multioutput-process 'natural gas, burned in Mini-BHKW, allocation heat' delivers the coproducts 'heat, at Mini-BHKW, allocation heat' and 'electricity, at Mini-BHKW, allocation heat'.; UUID: baa5adf6-1695-3aee-a42a-508802b8aac5 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, at Mini CHP plant, allocation heat (CH). All results are given per unit of the reference flow. ==== System boundary ==== The module includes fuel input, infrastructure, emissions to air, and substances needed for operation. ==== Technology ==== Specific manufacturer (Ecopower in Switzerland) ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Mini CHP plant, components for electricity only | technosphere | CH | 2.0029e-06 | p | none declared: tdc-doc default ±50 % | — | 100.0 | ████████████████████ | | ==== Data quality ==== 0 of 1 direct exchanges carry a declared pedigree, 0 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | none | | sampling procedure | Manufacturer information. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 1 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **4.525e-06** | 3.844e-06 | 7.258e-06 | 1.38 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.145e-06** | 2.439e-06 | 1.047e-05 | 2.13 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.001337** | 0.001115 | 0.002053 | 1.36 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.134e-07** | 2.598e-07 | 5.359e-07 | 1.44 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.001341** | 0.001119 | 0.002058 | 1.36 | | EF-particulate Matter | Impact on human health | disease incidence | **4.028e-11** | 3.524e-11 | 7.370e-11 | 1.44 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01233** | 0.007596 | 0.0331 | 2.11 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **4.627e-04** | 3.092e-04 | 0.001236 | 2.02 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01279** | 0.00796 | 0.03377 | 2.08 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **8.077e-07** | 6.814e-07 | 1.382e-06 | 1.42 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **7.850e-07** | 5.199e-07 | 4.290e-06 | 2.92 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **7.695e-06** | 6.456e-06 | 1.322e-05 | 1.43 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.389e-13** | 5.106e-13 | 1.396e-12 | 1.68 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.460e-12** | 7.203e-13 | 4.926e-12 | 2.66 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.999e-12** | 1.434e-12 | 5.633e-12 | 2.02 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.468e-11** | 3.088e-11 | 9.115e-11 | 1.71 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.691e-12** | 1.904e-12 | 5.406e-12 | 1.69 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.738e-11** | 3.399e-11 | 9.510e-11 | 1.67 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **3.469e-04** | 1.312e-04 | 0.002279 | 4.34 | | Land use | Soil quality index | pt (soil quality index) | **0.003624** | 0.003091 | 0.006894 | 1.51 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **5.501e-11** | 4.112e-11 | 1.069e-10 | 1.67 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **3.876e-06** | 3.298e-06 | 6.335e-06 | 1.4 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.02139** | 0.01765 | 0.0348 | 1.42 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.531e-08** | 2.320e-08 | 8.387e-08 | 1.96 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **1.069e-04** | -0.2564 | 0.1434 | — | Climate change 0.001341 kg CO2 eq per kWh. Main contributors: Mini CHP plant, components for electricity only 100 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Mini CHP plant, components for electricity only 100 %. Most sensitive exchanges (Section 6.3): Mini CHP plant, components for electricity only [CH] (-50.0 / +50.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 4.525e-06 | 8.443e-06 | 0.536 | | Climate change-Biogenic | 4.145e-06 | 4.145e-06 | 1.000 | | Climate change-Fossil | 0.001337 | 0.001337 | 1.000 | | Climate change-Land use and land use change | 3.134e-07 | 3.134e-07 | 1.000 | | Climate change | 0.001341 | 0.001341 | 1.000 | | EF-particulate Matter | 4.028e-11 | 4.028e-11 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.01233 | 0.01241 | 0.994 | | Ecotoxicity, freshwater_organics | 4.627e-04 | 4.614e-04 | 1.003 | | Ecotoxicity, freshwater | 0.01279 | 0.01285 | 0.995 | | Eutrophication marine | 8.077e-07 | 8.076e-07 | 1.000 | | Eutrophication, freshwater | 7.850e-07 | 7.850e-07 | 1.000 | | Eutrophication, terrestrial | 7.695e-06 | 8.281e-06 | 0.929 | | Human toxicity, cancer_inorganics | 5.389e-13 | 5.332e-13 | 1.011 | | Human toxicity, cancer_organics | 1.460e-12 | 1.460e-12 | 1.000 | | Human toxicity, cancer | 1.999e-12 | 1.994e-12 | 1.003 | | Human toxicity, non-cancer_inorganics | 3.468e-11 | 3.447e-11 | 1.006 | | Human toxicity, non-cancer_organics | 2.691e-12 | 2.690e-12 | 1.000 | | Human toxicity, non-cancer | 3.738e-11 | 3.716e-11 | 1.006 | | Ionising radiation, human health | 3.469e-04 | 3.469e-04 | 1.000 | | Land use | 0.003624 | 0.003092 | 1.172 | | Ozone depletion | 5.501e-11 | 5.501e-11 | 1.000 | | Photochemical ozone formation - human health | 3.876e-06 | 3.876e-06 | 1.000 | | Resource use, fossils | 0.02139 | 0.0214 | 1.000 | | Resource use, minerals and metals | 3.531e-08 | 1.508e-08 | 2.341 | | Water use | 1.069e-04 | 1.172e-04 | 0.912 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.001341 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 2.499 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Mini CHP plant, components for electricity only [CH] | 2.003e-06 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -50.0 / +50.0 | 50.0 (Ecotoxicity, freshwater_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.001341 kg CO2 eq per kWh (95 % interval 0.001119–0.002058). Dominant contributors: Mini CHP plant, components for electricity only 100 %. Most sensitive: Mini CHP plant, components for electricity only [CH] (-50.0 / +50.0 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **WARN** | 0/1 exchanges carry a distribution (0 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.001341 in [0.001119, 0.002058] | | time period declared | **PASS** | 2000-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].