====== Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:solar_system_30_m2_cu_flat_plate_collector_on_flat_roof_hot_water__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water [CH], per 1 p. EF v3.1 climate change 4223 kg CO2 eq (Monte Carlo 95 % interval 2611–1.295e+04). Main contributors: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water | | Dataset UUID / graph id | ''%%bf87aba3-fff4-364f-97f1-d80c66747ef2%%'' / ''%%activity:solar_system_30_m2_cu_flat_plate_collector_on_flat_roof_hot_water__ch%%'' | | Reference product, unit | Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water, 1 p | | Location | CH | | Time period | 2000-01/2010-12 | | Category | heat / solar\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Solar system with a flat plate collector on a multiple family dwelling for hot water. 25 years life time, 65 m pipe length and 1500 l heat storage. ; UUID: bf87aba3-fff4-364f-97f1-d80c66747ef2 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Solar system, 30 m2 Cu flat plate collector, on flat roof, hot water (CH). All results are given per unit of the reference flow. ==== System boundary ==== Production and disposal of a complete solar system (excluding auxiliary heating). Including different components, heat exchange fluid, warm water pipes, transports of parts to CH, and delivery with a van. ==== Technology ==== Solar collector system for hot water installed on the roof of a house. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Flat plate collector, copper absorber, at plant | technosphere | CH | 30 | m2 | lognormal, GSD² 4.81 | — | 42.0 | ████████ | | | Heat storage 2000l, at plant | technosphere | CH | 0.91848 | p | lognormal, GSD² 4.81 | — | 19.7 | ████ | | | Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 660 | tkm | lognormal, GSD² 3.79 | (3,5,3,1,1,5) | 16.9 | ███ | | | Steel, low-alloyed, at plant | technosphere | RER | 120 | kg | lognormal, GSD² 3.07 | — | 6.1 | █ | | | Concrete, normal, at plant | technosphere | CH | 0.63025 | m3 | lognormal, GSD² 3.07 | — | 3.4 | █ | | | Propylene glycol, liquid, at plant | technosphere | RER | 33.381 | kg | lognormal, GSD² 3.07 | — | 2.3 | · | | | Chromium steel 18/8, at plant | technosphere | RER | 18.92 | kg | lognormal, GSD² 3.07 | — | 2.0 | · | | | Treatment, heat carrier liquid, 40% C3H8O2, to wastewater treatment, class 2 | technosphere | CH | 0.090256 | m3 | lognormal, GSD² 3.07 | — | 1.9 | · | | | Expansion vessel 80l, at plant | technosphere | CH | 1.75 | p | lognormal, GSD² 4.81 | — | 1.9 | · | | | Tube insulation, elastomere, at plant | technosphere | DE | 14.703 | kg | lognormal, GSD² 3.07 | — | 1.6 | · | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 16.091 | kg | lognormal, GSD² 3.07 | — | 0.9 | · | | | Zinc coating, coils | technosphere | RER | 7.68 | m2 | lognormal, GSD² 3.07 | — | 0.7 | · | | | Pump 40W, at plant | technosphere | CH | 1.9444 | p | lognormal, GSD² 4.81 | — | 0.3 | · | | | Drawing of pipes, steel | technosphere | RER | 18.92 | kg | lognormal, GSD² 3.12 | — | 0.2 | · | | | Packaging film, LDPE, at plant | technosphere | RER | 1.3886 | kg | lognormal, GSD² 3.07 | — | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 147.16 | tkm | lognormal, GSD² 3.76 | — | 0.1 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 12.263 | tkm | lognormal, GSD² 3.76 | — | 0.1 | · | | | Water, completely softened, at plant | technosphere | RER | 56.875 | kg | lognormal, GSD² 3.07 | — | 0.0 | · | | ==== Data quality ==== 1 of 18 direct exchanges carry a declared pedigree, 18 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 5.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Stucki (ZHAW); data entry: Matthias Stucki (ZHAW); validation (proof reading): Niels Jungbluth (ESU) | | extrapolations | none | | sampling procedure | Own simulation. | | production volume | 10'433 systems with flat plate collectors were sold in 2008. 27.4% of the area is installed on multiple dwellings for hot water. | | uncertainty adjustments | none | | validation details | Proof reading validation: 17.12.2010; Other validation: \Server\E\ESU-Docs\Projekte laufend\352 Sonnenkollektoranlagen\Berechnung[neueingabe-Kollektoren-2.2+V1.0.xlsx]X-Process; | | time period comment | Time of simulation. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **32.93** | 15.23 | 141.3 | 3 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **10.26** | 5.807 | 44.32 | 2.79 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4210** | 2603 | 1.29e+04 | 2.25 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.39** | 1.137 | 9.908 | 3 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4223** | 2611 | 1.295e+04 | 2.25 | | EF-particulate Matter | Impact on human health | disease incidence | **2.608e-04** | 1.718e-04 | 0.001329 | 2.95 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.31e+04** | 2.829e+04 | 2.108e+05 | 2.79 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **724.8** | 476 | 2605 | 2.55 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.383e+04** | 2.882e+04 | 2.164e+05 | 2.77 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **5.061** | 2.897 | 17.86 | 2.53 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.73** | 1.965 | 51.65 | 5.43 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **62.46** | 37.92 | 208.2 | 2.35 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.463e-06** | 1.984e-06 | 1.970e-05 | 3.24 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.486e-06** | 1.016e-06 | 5.221e-06 | 2.42 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.949e-06** | 3.169e-06 | 2.419e-05 | 2.9 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.331e-04** | 1.204e-04 | 0.001385 | 3.59 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.645e-05** | 5.090e-06 | 7.930e-05 | 4.01 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.495e-04** | 1.260e-04 | 0.001495 | 3.58 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1208** | 368.5 | 1.004e+04 | 5.46 | | Land use | Soil quality index | pt (soil quality index) | **4.285e+04** | 2.449e+04 | 1.462e+05 | 2.51 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.753e-04** | 1.685e-04 | 8.636e-04 | 2.38 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **18.21** | 10.62 | 61.5 | 2.44 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **5.542e+04** | 3.379e+04 | 1.875e+05 | 2.36 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.1591** | 0.05212 | 0.7436 | — | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **336.2** | -1.871e+06 | 1.086e+06 | — | Climate change 4223 kg CO2 eq per p. Main contributors: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. Most sensitive exchanges (Section 6.3): Flat plate collector, copper absorber, at plant [CH] (-33.0 / +153.6 %); Heat storage 2000l, at plant [CH] (-15.4 / +72.0 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-12.3 / +45.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 32.93 | 35.46 | 0.928 | | Climate change-Biogenic | 10.26 | 10.26 | 1.000 | | Climate change-Fossil | 4210 | 4210 | 1.000 | | Climate change-Land use and land use change | 2.39 | 2.39 | 1.000 | | Climate change | 4223 | 4223 | 1.000 | | EF-particulate Matter | 2.608e-04 | 2.608e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 5.31e+04 | 5.357e+04 | 0.991 | | Ecotoxicity, freshwater_organics | 724.8 | 722.2 | 1.004 | | Ecotoxicity, freshwater | 5.383e+04 | 5.429e+04 | 0.992 | | Eutrophication marine | 5.061 | 5.061 | 1.000 | | Eutrophication, freshwater | 5.73 | 5.73 | 1.000 | | Eutrophication, terrestrial | 62.46 | 65.89 | 0.948 | | Human toxicity, cancer_inorganics | 3.463e-06 | 3.448e-06 | 1.004 | | Human toxicity, cancer_organics | 1.486e-06 | 1.486e-06 | 1.000 | | Human toxicity, cancer | 4.949e-06 | 4.934e-06 | 1.003 | | Human toxicity, non-cancer_inorganics | 2.331e-04 | 2.324e-04 | 1.003 | | Human toxicity, non-cancer_organics | 1.645e-05 | 1.645e-05 | 1.000 | | Human toxicity, non-cancer | 2.495e-04 | 2.489e-04 | 1.003 | | Ionising radiation, human health | 1208 | 1208 | 1.000 | | Land use | 4.285e+04 | 3.022e+04 | 1.418 | | Ozone depletion | 2.753e-04 | 2.753e-04 | 1.000 | | Photochemical ozone formation - human health | 18.21 | 18.21 | 1.000 | | Resource use, fossils | 5.542e+04 | 5.543e+04 | 1.000 | | Resource use, minerals and metals | 0.1591 | 0.1553 | 1.024 | | Water use | 336.2 | 382.3 | 0.879 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 4222 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.146e+07 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Flat plate collector, copper absorber, at plant [CH] | 30 m2 | ×0.215 / ×4.66 | lognormal, GSD² 4.81 | -33.0 / +153.6 | 328.6 (Human toxicity, non-cancer_organics) | | Heat storage 2000l, at plant [CH] | 0.9185 p | ×0.215 / ×4.66 | lognormal, GSD² 4.81 | -15.4 / +72.0 | 123.2 (Land use) | | Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 660 tkm | ×0.271 / ×3.69 | lognormal, GSD² 3.79 | -12.3 / +45.3 | 107.3 (Ozone depletion) | | Steel, low-alloyed, at plant [RER] | 120 kg | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -4.1 / +12.2 | 14.5 (Human toxicity, cancer_organics) | | Concrete, normal, at plant [CH] | 0.6302 m3 | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -2.3 / +6.8 | 6.9 (Climate change-Fossil) | | Expansion vessel 80l, at plant [CH] | 1.75 p | ×0.215 / ×4.66 | lognormal, GSD² 4.81 | -1.5 / +6.8 | 9.3 (Ionising radiation, human health) | | Propylene glycol, liquid, at plant [RER] | 33.38 kg | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -1.6 / +4.7 | 79.7 (Ecotoxicity, freshwater_inorganics) | | Chromium steel 18/8, at plant [RER] | 18.92 kg | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -1.3 / +4.0 | 6.2 (Human toxicity, cancer_inorganics) | | Treatment, heat carrier liquid, 40% C3H8O2, to wastewater treatment, class 2 [CH] | 0.09026 m3 | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -1.3 / +3.8 | 3.8 (Climate change-Fossil) | | Tube insulation, elastomere, at plant [DE] | 14.7 kg | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -1.0 / +3.1 | 7.4 (Climate change-Land use and land use change) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 16.09 kg | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -0.6 / +1.8 | 1.8 (Climate change-Fossil) | | Zinc coating, coils [RER] | 7.68 m2 | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -0.5 / +1.5 | 37.6 (Eutrophication, terrestrial) | | Pump 40W, at plant [CH] | 1.944 p | ×0.215 / ×4.66 | lognormal, GSD² 4.81 | -0.3 / +1.2 | 3.2 (Human toxicity, non-cancer_inorganics) | | Drawing of pipes, steel [RER] | 18.92 kg | ×0.328 / ×3.05 | lognormal, GSD² 3.12 | -0.1 / +0.4 | 2.9 (Climate change-Land use and land use change) | | Packaging film, LDPE, at plant [RER] | 1.389 kg | ×0.333 / ×3.01 | lognormal, GSD² 3.07 | -0.1 / +0.2 | 8.7 (Human toxicity, cancer_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 4223 kg CO2 eq per p (95 % interval 2611–1.295e+04). Dominant contributors: Flat plate collector, copper absorber, at plant 42 %; Heat storage 2000l, at plant 20 %; Transport, freight, lorry, 3.5t gross weight, fleet average 17 %; Steel, low-alloyed, at plant 6 %; Concrete, normal, at plant 3 %; Propylene glycol, liquid, at plant 2 %. Most sensitive: Flat plate collector, copper absorber, at plant [CH] (-33.0 / +153.6 %); Heat storage 2000l, at plant [CH] (-15.4 / +72.0 %); Transport, freight, lorry, 3.5t gross weight, fleet average [CH] (-12.3 / +45.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.7e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 18/18 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 4223 in [2611, 1.295e+04] | | time period declared | **PASS** | 2000-01/2010-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Stucki M., Jungbluth N. (2010) Update of the Life Cycle Inventories of Solar Collectors. Volume: 352. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Stucki M. Other authors: Jungbluth N. Year: 2010 Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 352 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].