====== 570 kWp open ground installation, multi-Si, on open ground — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:570_kwp_open_ground_installation_multi_si_on_open_ground__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 570 kWp open ground installation, multi-Si, on open ground [RER], per 1 p. EF v3.1 climate change 5.152e+05 kg CO2 eq (Monte Carlo 95 % interval 3.575e+05–1.329e+06). Main contributors: Photovoltaic panel, multi-Si, at regional storage 67 %; Open ground construction, on ground 24 %; Inverter, 500kW, at plant 5 %; Treatment, c-Si PV module 2 %; Electric installation, 570 kWp photovoltaic plant, at plant 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 570 kWp open ground installation, multi-Si, on open ground | | Dataset UUID / graph id | ''%%c35baca1-b81c-3185-b8b9-4f003fccbf09%%'' / ''%%activity:570_kwp_open_ground_installation_multi_si_on_open_ground__rer%%'' | | Reference product, unit | 570 kWp open ground installation, multi-Si, on open ground, 1 p | | Location | RER — Installation in Europe. | | Time period | 2014-01/2014-12 | | Category | chemicals / processing | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 570kWp and a life time of 30 years installed in Europe. The efficiency of multi-Si PV modules is 16.8% (Fraunhofer ISE Photovoltaics Report 2019). The share of rejected or replaced PV modules is estimated at 3%. The inverter is assumed to be replaced once during the service life of the PV system.; Synonyms: multi crystalline, single-Si; UUID: c35baca1-b81c-3185-b8b9-4f003fccbf09 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 570 kWp open ground installation, multi-Si, on open ground (RER). All results are given per unit of the reference flow. ==== System boundary ==== All components for the installation of a 570kWp photovoltaic plant, energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic panel, multi-Si, at regional storage | technosphere | RER | 3261.7 | m2 | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 66.5 | █████████████ | | | Open ground construction, on ground | technosphere | RER | 3166.7 | m2 | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 23.7 | █████ | | | Inverter, 500kW, at plant | technosphere | RER | 2.28 | p | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 5.4 | █ | | | Treatment, c-Si PV module | technosphere | RER | 43037 | kg | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 2.3 | · | | | Electric installation, 570 kWp photovoltaic plant, at plant | technosphere | ES | 1 | p | none declared: tdc-doc default ±50 % | — | 1.1 | · | | | Transport, freight, lorry, 7.5t-16t gross weight, fleet average | technosphere | RER | 9199.1 | tkm | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 0.8 | · | | | Diesel, burned in building machine, average | technosphere | CH | 7673.1 | MJ | lognormal, GSD² 1.1 | — | 0.2 | · | | | Electricity, low voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 36.033 | kWh | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 129.72 | MJ | lognormal, GSD² 1.1 | (3,4,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 7 of 9 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Estimations for lifetime of PV modules (30a) and inverters (15a) as well as for transport distances. | | sampling procedure | Publication for efficiency, mounting systems and own estimations for other components. | | production volume | Total installed capacity in 2018: 120 GWp in Europe. | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Average module efficiency in 2018. | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 1 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2254** | 1733 | 5208 | 1.77 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2273** | 1099 | 8745 | 2.86 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.125e+05** | 3.558e+05 | 1.324e+06 | 1.97 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **415** | 310.9 | 854 | 1.65 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.152e+05** | 3.575e+05 | 1.329e+06 | 1.97 | | EF-particulate Matter | Impact on human health | disease incidence | **0.02092** | 0.0165 | 0.1069 | 2.65 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.736e+06** | 1.870e+06 | 9.698e+06 | 2.31 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.991e+04** | 4.874e+04 | 1.754e+05 | 1.97 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.796e+06** | 1.915e+06 | 9.825e+06 | 2.3 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **582.8** | 412 | 1571 | 1.97 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **249.9** | 179.4 | 1347 | 2.82 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **4995** | 3830 | 1.216e+04 | 1.8 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.219e-04** | 1.897e-04 | 8.587e-04 | 2.17 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.405e-04** | 1.013e-04 | 4.057e-04 | 2.06 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.625e-04** | 3.164e-04 | 0.001179 | 2 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.01128** | 0.01056 | 0.03904 | 1.98 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.446e-04** | 4.143e-04 | 0.001186 | 1.73 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.01183** | 0.01116 | 0.04008 | 1.96 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.433e+05** | 4.801e+04 | 1.101e+06 | 5.21 | | Land use | Soil quality index | pt (soil quality index) | **1.460e+08** | 1.018e+08 | 2.507e+08 | 1.57 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.01521** | 0.0106 | 0.04833 | 2.16 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1540** | 1206 | 3829 | 1.82 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **6.836e+06** | 4.786e+06 | 1.813e+07 | 1.99 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **17.69** | 9.54 | 50.55 | 2.33 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **1.682e+05** | -1.512e+08 | 7.948e+07 | — | Climate change 5.152e+05 kg CO2 eq per p. Main contributors: Photovoltaic panel, multi-Si, at regional storage 67 %; Open ground construction, on ground 24 %; Inverter, 500kW, at plant 5 %; Treatment, c-Si PV module 2 %; Electric installation, 570 kWp photovoltaic plant, at plant 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic panel, multi-Si, at regional storage 67 %; Open ground construction, on ground 24 %; Inverter, 500kW, at plant 5 %; Treatment, c-Si PV module 2 %; Electric installation, 570 kWp photovoltaic plant, at plant 1 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel, multi-Si, at regional storage [RER] (-5.9 / +6.5 %); Open ground construction, on ground [RER] (-2.1 / +2.3 %); Electric installation, 570 kWp photovoltaic plant, at plant [ES] (-0.6 / +0.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2254 | 2359 | 0.956 | | Climate change-Biogenic | 2273 | 2273 | 1.000 | | Climate change-Fossil | 5.125e+05 | 5.125e+05 | 1.000 | | Climate change-Land use and land use change | 415 | 415 | 1.000 | | Climate change | 5.152e+05 | 5.152e+05 | 1.000 | | EF-particulate Matter | 0.02092 | 0.02092 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.736e+06 | 2.791e+06 | 0.980 | | Ecotoxicity, freshwater_organics | 5.991e+04 | 5.153e+04 | 1.163 | | Ecotoxicity, freshwater | 2.796e+06 | 2.840e+06 | 0.984 | | Eutrophication marine | 582.8 | 582.8 | 1.000 | | Eutrophication, freshwater | 249.9 | 249.9 | 1.000 | | Eutrophication, terrestrial | 4995 | 5172 | 0.966 | | Human toxicity, cancer_inorganics | 2.219e-04 | 2.208e-04 | 1.005 | | Human toxicity, cancer_organics | 1.405e-04 | 1.405e-04 | 1.000 | | Human toxicity, cancer | 3.625e-04 | 3.613e-04 | 1.003 | | Human toxicity, non-cancer_inorganics | 0.01128 | 0.01124 | 1.004 | | Human toxicity, non-cancer_organics | 5.446e-04 | 5.442e-04 | 1.001 | | Human toxicity, non-cancer | 0.01183 | 0.01178 | 1.004 | | Ionising radiation, human health | 1.433e+05 | 1.433e+05 | 1.000 | | Land use | 1.460e+08 | 1.453e+08 | 1.005 | | Ozone depletion | 0.01521 | 0.01521 | 1.000 | | Photochemical ozone formation - human health | 1540 | 1540 | 1.000 | | Resource use, fossils | 6.836e+06 | 6.838e+06 | 1.000 | | Resource use, minerals and metals | 17.69 | 17.43 | 1.015 | | Water use | 1.682e+05 | 1.698e+05 | 0.991 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 5.145e+05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.326e+09 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic panel, multi-Si, at regional storage [RER] | 3262 m2 | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -5.9 / +6.5 | 8.7 (Water use) | | Open ground construction, on ground [RER] | 3167 m2 | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -2.1 / +2.3 | 9.6 (Land use) | | Electric installation, 570 kWp photovoltaic plant, at plant [ES] | 1 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -0.6 / +0.6 | 11.3 (Human toxicity, non-cancer_organics) | | Inverter, 500kW, at plant [RER] | 2.28 p | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -0.5 / +0.5 | 2.8 (Human toxicity, non-cancer_organics) | | Treatment, c-Si PV module [RER] | 4.304e+04 kg | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -0.2 / +0.2 | 0.3 (Climate change-Land use and land use change) | | Transport, freight, lorry, 7.5t-16t gross weight, fleet average [RER] | 9199 tkm | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -0.1 / +0.1 | 0.4 (Climate change-Land use and land use change) | | Diesel, burned in building machine, average [CH] | 7673 MJ | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_organics) | | Electricity, low voltage, production ENTSO-E, at grid [ENTSO-E] | 36.03 kWh | ×0.911 / ×1.1 | lognormal, GSD² 1.1 | -0.0 / +0.0 | 0.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | 570 kWp open ground installation, multi-Si, on open ground [ES] | 5.233e+05 kg CO2 eq | 5.152e+05 | 0.98 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 5.152e+05 kg CO2 eq per p (95 % interval 3.575e+05–1.329e+06). Dominant contributors: Photovoltaic panel, multi-Si, at regional storage 67 %; Open ground construction, on ground 24 %; Inverter, 500kW, at plant 5 %; Treatment, c-Si PV module 2 %; Electric installation, 570 kWp photovoltaic plant, at plant 1 %. Most sensitive: Photovoltaic panel, multi-Si, at regional storage [RER] (-5.9 / +6.5 %); Open ground construction, on ground [RER] (-2.1 / +2.3 %); Electric installation, 570 kWp photovoltaic plant, at plant [ES] (-0.6 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 24/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/9 exchanges carry a distribution (89 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 5.152e+05 in [3.575e+05, 1.329e+06] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].