====== Electricity, production mix photovoltaic, at plant — MX ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_production_mix_photovoltaic_at_plant__mx|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, production mix photovoltaic, at plant [MX], per 1 kWh. EF v3.1 climate change 0.01749 kg CO2 eq (Monte Carlo 95 % interval 0.01477–0.03948). Main contributors: 570 kWp open ground installation, multi-Si, on open ground 54 %; 570 kWp open ground installation, single-Si, on open ground 28 %; 156 kWp flat-roof installation, multi-Si, on roof 3 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 3 %; 3kWp flat roof installation, multi-Si, on roof 2 %; 570 kWp open ground installation, CIS, on open ground 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, production mix photovoltaic, at plant | | Dataset UUID / graph id | ''%%c5497f52-a5e4-3da9-8b20-fb829ed78b31%%'' / ''%%activity:electricity_production_mix_photovoltaic_at_plant__mx%%'' | | Reference product, unit | Electricity, production mix photovoltaic, at plant, 1 kWh | | Location | MX — undefined | | Time period | 2005-01/2018-12 | | Category | electricity by fuel / photovoltaic | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Annual output of grid-connected PV power plants differentiated for roof-top, facade and centralized power plants. Technology and installation type breakdown based on literature (IEA-PVPS Task 1 and Fraunhofer ISE reports) and expert estimates. Average yield based on population-weighted average according to Breyer & Schmid (2010), corrected by performance ratio as specified in IEA-PVPS Task 12 methodology guidelines. The lifetime of PV systems is estimated at 30 years based on the PEFCR PV electricity. Technology: Electricity production with grid-connected photovoltaic power plants. Time period: Time of publications Version: 1 Energy values: Undefined 100.0 Production volume: Unknown. Local category: Photovoltaik Local subcategory: Kraftwerke UVEK 2022 source file:174-photovoltaics-global-supply-chain-v2.5._X-elec-Americas.xml UUID: c5497f52-a5e4-3da9-8b20-fb829ed78b31 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, production mix photovoltaic, at plant (MX). All results are given per unit of the reference flow. ==== System boundary ==== Production mix of photovoltaic electricity in the country. Annual output, Roof-Top: 1612, Annual output, Facade: 1128 kWh/kWp, Annual output, centralized PV systems: 1709 kWh/kWp. Amount of solar energy transformed to electricity. Waste heat emission due to losses of electricity in the system. ==== Technology ==== Electricity production with grid-connected photovoltaic power plants. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | 570 kWp open ground installation, multi-Si, on open ground | technosphere | RER | 1.8357e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 54.1 | ███████████ | | | 570 kWp open ground installation, single-Si, on open ground | technosphere | RER | 9.7221e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 28.1 | ██████ | | | 156 kWp flat-roof installation, multi-Si, on roof | technosphere | CH | 3.6354e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 2.8 | █ | | | 93 kWp slanted-roof installation, multi-Si, panel, mounted, on roof | technosphere | CH | 6.7757e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 2.8 | █ | | | 3kWp flat roof installation, multi-Si, on roof | technosphere | US | 9.4521e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.7 | · | | | 570 kWp open ground installation, CIS, on open ground | technosphere | RER | 5.7366e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.5 | · | | | 156 kWp flat-roof installation, single-Si, on roof | technosphere | CH | 1.9253e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.5 | · | | | 93 kWp slanted-roof installation, single-Si, panel, mounted, on roof | technosphere | CH | 3.5884e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.4 | · | | | 570 kWp open ground installation, CdTe, on open ground | technosphere | RER | 6.9443e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.4 | · | | | 3kWp slanted-roof installation, multi-Si, panel, mounted, on roof | technosphere | US | 7.7586e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 1.3 | · | | | 3kWp flat roof installation, single-Si, on roof | technosphere | US | 5.0059e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.9 | · | | | 3kWp slanted-roof installation, single-Si, panel, mounted, on roof | technosphere | US | 4.1090e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.7 | · | | | 570 kWp open ground installation, micro-Si, on open ground | technosphere | RER | 9.0578e-11 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.5 | · | | | 3kWp slanted-roof installation, CIS, panel, mounted, on roof | technosphere | CH | 1.7720e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof | technosphere | CH | 2.1450e-08 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.3 | · | | | 3kWp facade installation, multi-Si, panel, mounted, at building | technosphere | US | 9.0020e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.2 | · | | | 93 kWp slanted-roof installation, multi-Si, laminated, integrated, on roof | technosphere | CH | 4.0654e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp facade installation, multi-Si, laminated, integrated, at building | technosphere | US | 9.0020e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp facade installation, single-Si, panel, mounted, at building | technosphere | US | 4.7675e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 93 kWp slanted-roof installation, single-Si, laminated, integrated, on roof | technosphere | CH | 2.1531e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp slanted-roof installation, micro-Si, panel, mounted, on roof | technosphere | RER | 2.7979e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp facade installation, single-Si, laminated, integrated, at building | technosphere | US | 4.7675e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp slanted-roof installation, multi-Si, laminated, integrated, on roof | technosphere | US | 4.6552e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.1 | · | | | 3kWp slanted-roof installation, single-Si, laminated, integrated, on roof | technosphere | US | 2.4654e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, CdTe, laminated, integrated, on roof | technosphere | CH | 1.2870e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, CIS, laminated, integrated, on roof | technosphere | CH | 1.0632e-09 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | Treatment, sewage, from residence, to wastewater treatment, class 2 | technosphere | CH | 1.9292e-06 | m3 | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | 3kWp slanted-roof installation, micro-Si, laminated, integrated, on roof | technosphere | RER | 1.6787e-10 | p | lognormal, GSD² 1.22 | (2,2,1,1,1,3) | 0.0 | · | | | Tap water, water balance according to MoeK 2013, at user | technosphere | MX | 0.0021436 | kg | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Energy, Solar, Converted | elementary | natural resource | 3.8503 | MJ | lognormal, GSD² 1.09 | (2,2,1,1,1,3) | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.25027 | MJ | lognormal, GSD² 1.05 | — | 0.0 | · | | | Water vapour | elementary | air/Unknown | 2.1436e-07 | m3 | lognormal, GSD² 1.09 | — | 0.0 | · | | ==== Data quality ==== 30 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 2.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 3.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Use of PV technology data investigated for other countries (Switzerland). Correction of average yield with Swiss data. | | sampling procedure | Statistical data and model calculations | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Time of publications | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **7.554e-05** | 6.866e-05 | 1.628e-04 | 1.56 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.710e-05** | 4.992e-05 | 2.777e-04 | 2.45 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.0174** | 0.01471 | 0.03932 | 1.68 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.360e-05** | 1.153e-05 | 2.655e-05 | 1.54 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.01749** | 0.01477 | 0.03948 | 1.68 | | EF-particulate Matter | Impact on human health | disease incidence | **6.873e-10** | 6.327e-10 | 3.918e-09 | 2.47 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.0961** | 0.08521 | 0.2979 | 1.92 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.002108** | 0.001969 | 0.005628 | 1.75 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.0982** | 0.08767 | 0.3022 | 1.91 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.120e-05** | 1.827e-05 | 5.046e-05 | 1.69 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **9.500e-06** | 7.740e-06 | 5.281e-05 | 2.7 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.674e-04** | 1.510e-04 | 3.731e-04 | 1.59 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.585e-12** | 7.232e-12 | 2.816e-11 | 2 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.750e-12** | 3.984e-12 | 1.243e-11 | 1.79 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.234e-11** | 1.195e-11 | 3.743e-11 | 1.8 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.974e-10** | 4.135e-10 | 1.327e-09 | 1.83 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.929e-11** | 1.627e-11 | 4.194e-11 | 1.62 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.167e-10** | 4.349e-10 | 1.360e-09 | 1.8 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.004743** | 0.001724 | 0.03872 | 4.98 | | Land use | Soil quality index | pt (soil quality index) | **4.227** | 2.929 | 7.38 | 1.59 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **5.408e-10** | 4.647e-10 | 1.465e-09 | 1.8 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **5.282e-05** | 4.897e-05 | 1.210e-04 | 1.6 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.2321** | 0.2004 | 0.5678 | 1.7 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **7.212e-07** | 5.633e-07 | 1.587e-06 | 1.71 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.008799** | -5.249 | 2.552 | — | Climate change 0.01749 kg CO2 eq per kWh. Main contributors: 570 kWp open ground installation, multi-Si, on open ground 54 %; 570 kWp open ground installation, single-Si, on open ground 28 %; 156 kWp flat-roof installation, multi-Si, on roof 3 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 3 %; 3kWp flat roof installation, multi-Si, on roof 2 %; 570 kWp open ground installation, CIS, on open ground 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: 570 kWp open ground installation, multi-Si, on open ground 54 %; 570 kWp open ground installation, single-Si, on open ground 28 %; 156 kWp flat-roof installation, multi-Si, on roof 3 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 3 %; 3kWp flat roof installation, multi-Si, on roof 2 %; 570 kWp open ground installation, CIS, on open ground 2 %. Most sensitive exchanges (Section 6.3): 570 kWp open ground installation, multi-Si, on open ground [RER] (-9.4 / +11.4 %); 570 kWp open ground installation, single-Si, on open ground [RER] (-4.9 / +6.0 %); 156 kWp flat-roof installation, multi-Si, on roof [CH] (-0.5 / +0.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 7.554e-05 | 7.928e-05 | 0.953 | | Climate change-Biogenic | 7.710e-05 | 7.710e-05 | 1.000 | | Climate change-Fossil | 0.0174 | 0.0174 | 1.000 | | Climate change-Land use and land use change | 1.360e-05 | 1.360e-05 | 1.000 | | Climate change | 0.01749 | 0.01749 | 1.000 | | EF-particulate Matter | 6.873e-10 | 6.873e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.0961 | 0.09805 | 0.980 | | Ecotoxicity, freshwater_organics | 0.002108 | 0.001812 | 1.163 | | Ecotoxicity, freshwater | 0.0982 | 0.09974 | 0.985 | | Eutrophication marine | 2.120e-05 | 2.120e-05 | 1.000 | | Eutrophication, freshwater | 9.500e-06 | 9.500e-06 | 1.000 | | Eutrophication, terrestrial | 1.674e-04 | 1.732e-04 | 0.966 | | Human toxicity, cancer_inorganics | 7.585e-12 | 7.545e-12 | 1.005 | | Human toxicity, cancer_organics | 4.750e-12 | 4.750e-12 | 1.000 | | Human toxicity, cancer | 1.234e-11 | 1.230e-11 | 1.003 | | Human toxicity, non-cancer_inorganics | 3.974e-10 | 3.956e-10 | 1.005 | | Human toxicity, non-cancer_organics | 1.929e-11 | 1.928e-11 | 1.001 | | Human toxicity, non-cancer | 4.167e-10 | 4.149e-10 | 1.004 | | Ionising radiation, human health | 0.004743 | 0.004743 | 1.000 | | Land use | 4.227 | 4.204 | 1.005 | | Ozone depletion | 5.408e-10 | 5.408e-10 | 1.000 | | Photochemical ozone formation - human health | 5.282e-05 | 5.282e-05 | 1.000 | | Resource use, fossils | 0.2321 | 0.2322 | 1.000 | | Resource use, minerals and metals | 7.212e-07 | 7.121e-07 | 1.013 | | Water use | 0.008799 | 0.008756 | 1.005 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.01747 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 53.38 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | 570 kWp open ground installation, multi-Si, on open ground [RER] | 1.836e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -9.4 / +11.4 | 13.4 (Land use) | | 570 kWp open ground installation, single-Si, on open ground [RER] | 9.722e-09 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -4.9 / +6.0 | 10.3 (Water use) | | 156 kWp flat-roof installation, multi-Si, on roof [CH] | 3.635e-09 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 0.7 (Human toxicity, non-cancer_organics) | | 93 kWp slanted-roof installation, multi-Si, panel, mounted, on roof [CH] | 6.776e-09 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.5 / +0.6 | 0.6 (Climate change-Biogenic) | | 3kWp flat roof installation, multi-Si, on roof [US] | 9.452e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.4 | 1.4 (Resource use, minerals and metals) | | 570 kWp open ground installation, CIS, on open ground [RER] | 5.737e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.3 | 1.3 (Ozone depletion) | | 156 kWp flat-roof installation, single-Si, on roof [CH] | 1.925e-09 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.3 | 0.5 (Water use) | | 93 kWp slanted-roof installation, single-Si, panel, mounted, on roof [CH] | 3.588e-09 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.3 / +0.3 | 0.6 (Water use) | | 570 kWp open ground installation, CdTe, on open ground [RER] | 6.944e-10 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.2 / +0.3 | 0.5 (Land use) | | 3kWp slanted-roof installation, multi-Si, panel, mounted, on roof [US] | 7.759e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.2 / +0.3 | 1.1 (Resource use, minerals and metals) | | 3kWp flat roof installation, single-Si, on roof [US] | 5.006e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.2 / +0.2 | 0.7 (Resource use, minerals and metals) | | 3kWp slanted-roof installation, single-Si, panel, mounted, on roof [US] | 4.109e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.6 (Resource use, minerals and metals) | | 570 kWp open ground installation, micro-Si, on open ground [RER] | 9.058e-11 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.1 (Climate change-Land use and land use change) | | 3kWp slanted-roof installation, CIS, panel, mounted, on roof [CH] | 1.772e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.1 | 0.2 (Ozone depletion) | | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof [CH] | 2.145e-08 p | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.1 | 0.3 (Resource use, minerals and metals) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Electricity, production mix photovoltaic, at plant [IL] | 0.01673 kg CO2 eq | 0.01749 | 1.05 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [ZA] | 0.01723 kg CO2 eq | 0.01749 | 1.02 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [CL] | 0.01751 kg CO2 eq | 0.01749 | 1.00 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [US] | 0.01921 kg CO2 eq | 0.01749 | 0.91 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [TH] | 0.01963 kg CO2 eq | 0.01749 | 0.89 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [BE] | 0.0319 kg CO2 eq | 0.01749 | 0.55 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [FI] | 0.03271 kg CO2 eq | 0.01749 | 0.53 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [GB] | 0.0339 kg CO2 eq | 0.01749 | 0.52 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [NO] | 0.03502 kg CO2 eq | 0.01749 | 0.50 | same dataset name, other location | | bafu | Electricity, production mix photovoltaic, at plant [IE] | 0.0361 kg CO2 eq | 0.01749 | 0.48 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 0.01749 kg CO2 eq per kWh (95 % interval 0.01477–0.03948). Dominant contributors: 570 kWp open ground installation, multi-Si, on open ground 54 %; 570 kWp open ground installation, single-Si, on open ground 28 %; 156 kWp flat-roof installation, multi-Si, on roof 3 %; 93 kWp slanted-roof installation, multi-Si, panel, mounted, … 3 %; 3kWp flat roof installation, multi-Si, on roof 2 %; 570 kWp open ground installation, CIS, on open ground 2 %. Most sensitive: 570 kWp open ground installation, multi-Si, on open ground [RER] (-9.4 / +11.4 %); 570 kWp open ground installation, single-Si, on open ground [RER] (-4.9 / +6.0 %); 156 kWp flat-roof installation, multi-Si, on roof [CH] (-0.5 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 24/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.01749 in [0.01477, 0.03948] | | time period declared | **PASS** | 2005-01/2018-12 | | geography is a known location code | **PASS** | MX | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].