====== Electricity, high voltage, water utility Zug, at grid — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_high_voltage_water_utility_zug_at_grid__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, high voltage, water utility Zug, at grid [CH], per 1 kWh. EF v3.1 climate change 0.008498 kg CO2 eq (Monte Carlo 95 % interval 0.006749–0.01455). Main contributors: Electricity mix, water utility Zug, at plant 71 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, high voltage, water utility Zug, at grid | | Dataset UUID / graph id | ''%%c65ceb83-5a36-351e-873d-98bfe043f94f%%'' / ''%%activity:electricity_high_voltage_water_utility_zug_at_grid__ch%%'' | | Reference product, unit | Electricity, high voltage, water utility Zug, at grid, 1 kWh | | Location | CH — Data apply to the supply area of the electric utility Obwalden. | | Time period | 1992-01/2013-12 | | Category | electricity / supply mix | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transmission of high voltage electricity.; UUID: c65ceb83-5a36-351e-873d-98bfe043f94f This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, high voltage, water utility Zug, at grid (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in the water utility Zug, the transmission network and direct emissions to air (ozone and N2O). Electricity losses are accounted for. ==== Technology ==== Average technology used to transmit and distribute electricity. Includes underground and overhead lines. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity mix, water utility Zug, at plant | technosphere | CH | 1.033 | kWh | lognormal, GSD² 1.05 | — | 71.4 | ██████████████ | | | Transmission network, electricity, high voltage | technosphere | CH | 6.6958e-09 | km | lognormal, GSD² 3.09 | — | 12.5 | ███ | | | Nitrous Oxide | elementary | air/Unknown | 5.0000e-06 | kg | lognormal, GSD² 1.62 | — | 16.1 | ███ | | | Waste Heat | elementary | air/Unknown | 0.11293 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Waste Heat | elementary | soil/Unknown | 0.0059435 | MJ | lognormal, GSD² 1.24 | — | 0.0 | · | | | Ozone | elementary | air/Unknown | 4.5000e-06 | kg | lognormal, GSD² 1.58 | — | 0.0 | · | | ==== Data quality ==== 0 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | Statistical data. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 08.05.2015; Other validation: \SRV01\ESU-Docs\Projekte laufend\527 Bilanz Holzpur\EcoSpold[527-Ökobilanz-holzpur-v0.16.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.828e-05** | 1.431e-05 | 3.608e-05 | 1.61 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.277e-04** | 4.232e-04 | 6.932e-04 | 1.3 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.007197** | 0.005505 | 0.01308 | 1.58 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.736e-04** | 5.186e-04 | 0.001131 | 1.52 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.008498** | 0.006749 | 0.01455 | 1.49 | | EF-particulate Matter | Impact on human health | disease incidence | **6.202e-10** | 4.204e-10 | 1.286e-09 | 1.74 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01456** | 0.01273 | 0.0352 | 1.67 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.335e-04** | 4.678e-04 | 0.001408 | 1.91 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.0151** | 0.01326 | 0.03589 | 1.67 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **7.877e-06** | 6.376e-06 | 1.332e-05 | 1.46 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.850e-06** | 1.852e-06 | 2.854e-05 | 4.01 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.121e-04** | 9.506e-05 | 1.673e-04 | 1.33 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.152e-12** | 1.806e-12 | 6.950e-12 | 2 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.194e-11** | 7.389e-12 | 2.198e-11 | 1.73 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.410e-11** | 1.027e-11 | 2.583e-11 | 1.61 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.389e-10** | 1.208e-10 | 4.386e-10 | 1.96 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.913e-12** | 5.716e-12 | 1.793e-11 | 1.81 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.468e-10** | 1.277e-10 | 4.524e-10 | 1.94 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.001498** | 5.522e-04 | 0.01206 | 4.58 | | Land use | Soil quality index | pt (soil quality index) | **0.5862** | 0.3411 | 1.044 | 1.76 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **8.085e-11** | 6.588e-11 | 1.752e-10 | 1.63 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.699e-05** | 2.171e-05 | 4.872e-05 | 1.5 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.05274** | 0.0414 | 0.1097 | 1.67 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **6.984e-08** | 4.277e-08 | 1.955e-07 | 2.14 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **3.381e-04** | -35.06 | 15.43 | — | Climate change 0.008498 kg CO2 eq per kWh. Main contributors: Electricity mix, water utility Zug, at plant 71 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity mix, water utility Zug, at plant 71 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. Most sensitive exchanges (Section 6.3): Transmission network, electricity, high voltage [CH] (-8.4 / +25.3 %); Nitrous Oxide [air/Unknown] (-6.1 / +9.8 %); Electricity mix, water utility Zug, at plant [CH] (-3.3 / +3.5 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.828e-05 | 3.175e-05 | 0.576 | | Climate change-Biogenic | 5.277e-04 | 5.277e-04 | 1.000 | | Climate change-Fossil | 0.007197 | 0.007197 | 1.000 | | Climate change-Land use and land use change | 7.736e-04 | 7.736e-04 | 1.000 | | Climate change | 0.008498 | 0.008498 | 1.000 | | EF-particulate Matter | 6.202e-10 | 6.202e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.01456 | 0.01489 | 0.978 | | Ecotoxicity, freshwater_organics | 5.335e-04 | 5.307e-04 | 1.005 | | Ecotoxicity, freshwater | 0.0151 | 0.01541 | 0.980 | | Eutrophication marine | 7.877e-06 | 7.876e-06 | 1.000 | | Eutrophication, freshwater | 2.850e-06 | 2.850e-06 | 1.000 | | Eutrophication, terrestrial | 1.121e-04 | 1.101e-04 | 1.018 | | Human toxicity, cancer_inorganics | 2.152e-12 | 2.141e-12 | 1.005 | | Human toxicity, cancer_organics | 1.194e-11 | 1.194e-11 | 1.000 | | Human toxicity, cancer | 1.410e-11 | 1.408e-11 | 1.001 | | Human toxicity, non-cancer_inorganics | 1.389e-10 | 1.384e-10 | 1.003 | | Human toxicity, non-cancer_organics | 7.913e-12 | 7.913e-12 | 1.000 | | Human toxicity, non-cancer | 1.468e-10 | 1.464e-10 | 1.003 | | Ionising radiation, human health | 0.001498 | 0.001498 | 1.000 | | Land use | 0.5862 | 0.4523 | 1.296 | | Ozone depletion | 8.085e-11 | 8.085e-11 | 1.000 | | Photochemical ozone formation - human health | 2.699e-05 | 2.699e-05 | 1.000 | | Resource use, fossils | 0.05274 | 0.05275 | 1.000 | | Resource use, minerals and metals | 6.984e-08 | 6.944e-08 | 1.006 | | Water use | 3.381e-04 | 5.489e-04 | 0.616 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.008498 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 26.9 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Transmission network, electricity, high voltage [CH] | 6.696e-09 km | ×0.331 / ×3.02 | lognormal, GSD² 3.09 | -8.4 / +25.3 | 102.7 (Resource use, minerals and metals) | | Nitrous Oxide [air/Unknown] | 5.000e-06 kg | ×0.621 / ×1.61 | lognormal, GSD² 1.62 | -6.1 / +9.8 | 11.6 (Climate change-Fossil) | | Electricity mix, water utility Zug, at plant [CH] | 1.033 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -3.3 / +3.5 | 4.9 (Climate change-Land use and land use change) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.008498 kg CO2 eq per kWh (95 % interval 0.006749–0.01455). Dominant contributors: Electricity mix, water utility Zug, at plant 71 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. Most sensitive: Transmission network, electricity, high voltage [CH] (-8.4 / +25.3 %); Nitrous Oxide [air/Unknown] (-6.1 / +9.8 %); Electricity mix, water utility Zug, at plant [CH] (-3.3 / +3.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 22/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.008498 in [0.006749, 0.01455] | | time period declared | **PASS** | 1992-01/2013-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Stolz P., Frischknecht R. (2015) Ökobilanz Vollholzsystem holzpur. Project report. Volume: 527. treeze Ltd.. Uster, CH. Type: Separate publication Source: Report First author: Stolz P. Other authors: Frischknecht R. Year: 2015 Title of anthology: Project report Place of publication: Uster, CH Publisher: treeze Ltd. Volume No: 527 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].