====== Disposal of heat dissipation system, apartment building Ecofaubourg B — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_of_heat_dissipation_system_apartment_building_ecofaubourg_b__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal of heat dissipation system, apartment building Ecofaubourg B [CH], per 1 m2. EF v3.1 climate change 0.02096 kg CO2 eq (Monte Carlo 95 % interval 0.01835–0.02507). Main contributors: Disposal, various components for heating system 59 %; Disposal, multicolumn radiator 37 %; Disposal, convector radiator 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal of heat dissipation system, apartment building Ecofaubourg B | | Dataset UUID / graph id | ''%%c78fc206-bf26-4b63-b29c-67ab98efce00%%'' / ''%%activity:disposal_of_heat_dissipation_system_apartment_building_ecofaubourg_b__ch%%'' | | Reference product, unit | Disposal of heat dissipation system, apartment building Ecofaubourg B, 1 m2 | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 1994-01/2008-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of components for the heat dissipation system; UUID: c78fc206-bf26-4b63-b29c-67ab98efce00 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m2** of Disposal of heat dissipation system, apartment building Ecofaubourg B (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, various components for heating system | technosphere | CH | 0.03078 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 58.6 | ████████████ | | | Disposal, multicolumn radiator | technosphere | CH | 1.339 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 37.3 | ███████ | | | Disposal, convector radiator | technosphere | CH | 0.1455 | kg | lognormal, GSD² 1.07 | (1,1,1,1,1,1) | 4.1 | █ | | ==== Data quality ==== 3 of 3 direct exchanges carry a declared pedigree, 3 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 1.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Klingler; data entry: Matthias Klingler; validation (proof reading): Matthias Klingler | | extrapolations | none | | sampling procedure | Waste-specific calculation based on input data from call of bids for a heating system of a specific building. | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.188e-05** | 1.039e-05 | 1.588e-05 | 1.24 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.507e-05** | 1.116e-05 | 2.586e-05 | 1.54 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02094** | 0.01834 | 0.02505 | 1.18 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.249e-06** | 1.749e-06 | 3.399e-06 | 1.41 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.02096** | 0.01835 | 0.02507 | 1.18 | | EF-particulate Matter | Impact on human health | disease incidence | **1.807e-10** | 1.625e-10 | 2.565e-10 | 1.26 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.03348** | 0.02774 | 0.08234 | 1.75 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.001073** | 8.364e-04 | 0.002059 | 1.59 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.03456** | 0.02888 | 0.08398 | 1.73 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **9.219e-06** | 7.902e-06 | 1.188e-05 | 1.23 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **7.878e-07** | 5.264e-07 | 3.374e-06 | 2.56 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **7.872e-05** | 6.752e-05 | 1.027e-04 | 1.24 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.915e-12** | 1.562e-12 | 2.634e-11 | 4.27 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.110e-13** | 6.177e-13 | 1.091e-12 | 1.33 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.626e-12** | 2.332e-12 | 2.718e-11 | 3.53 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.562e-11** | 6.260e-11 | 2.389e-10 | 1.94 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.792e-12** | 4.064e-12 | 7.045e-12 | 1.33 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **7.041e-11** | 6.775e-11 | 2.439e-10 | 1.89 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.003031** | 0.001052 | 0.01817 | 4.18 | | Land use | Soil quality index | pt (soil quality index) | **0.08845** | 0.04119 | 0.1525 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.285e-10** | 1.828e-10 | 3.318e-10 | 1.35 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **3.538e-05** | 2.930e-05 | 4.897e-05 | 1.29 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.101** | 0.08548 | 0.1349 | 1.26 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.529e-08** | 1.172e-08 | 3.082e-08 | 1.66 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **8.045e-04** | -1.16 | 0.5999 | — | Climate change 0.02096 kg CO2 eq per m2. Main contributors: Disposal, various components for heating system 59 %; Disposal, multicolumn radiator 37 %; Disposal, convector radiator 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, various components for heating system 59 %; Disposal, multicolumn radiator 37 %; Disposal, convector radiator 4 %. Most sensitive exchanges (Section 6.3): Disposal, various components for heating system [CH] (-3.8 / +4.1 %); Disposal, multicolumn radiator [CH] (-2.4 / +2.6 %); Disposal, convector radiator [CH] (-0.3 / +0.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.188e-05 | 2.267e-05 | 0.524 | | Climate change-Biogenic | 1.507e-05 | 1.507e-05 | 1.000 | | Climate change-Fossil | 0.02094 | 0.02094 | 1.000 | | Climate change-Land use and land use change | 2.249e-06 | 2.249e-06 | 1.000 | | Climate change | 0.02096 | 0.02096 | 1.000 | | EF-particulate Matter | 1.807e-10 | 1.807e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.03348 | 0.03385 | 0.989 | | Ecotoxicity, freshwater_organics | 0.001073 | 0.00107 | 1.003 | | Ecotoxicity, freshwater | 0.03456 | 0.03445 | 1.003 | | Eutrophication marine | 9.219e-06 | 9.218e-06 | 1.000 | | Eutrophication, freshwater | 7.878e-07 | 7.878e-07 | 1.000 | | Eutrophication, terrestrial | 7.872e-05 | 9.796e-05 | 0.804 | | Human toxicity, cancer_inorganics | 2.915e-12 | 2.906e-12 | 1.003 | | Human toxicity, cancer_organics | 7.110e-13 | 7.110e-13 | 1.000 | | Human toxicity, cancer | 3.626e-12 | 3.617e-12 | 1.002 | | Human toxicity, non-cancer_inorganics | 6.562e-11 | 6.418e-11 | 1.022 | | Human toxicity, non-cancer_organics | 4.792e-12 | 4.791e-12 | 1.000 | | Human toxicity, non-cancer | 7.041e-11 | 6.897e-11 | 1.021 | | Ionising radiation, human health | 0.003031 | 0.003031 | 1.000 | | Land use | 0.08845 | 0.05436 | 1.627 | | Ozone depletion | 2.285e-10 | 2.285e-10 | 1.000 | | Photochemical ozone formation - human health | 3.538e-05 | 3.538e-05 | 1.000 | | Resource use, fossils | 0.101 | 0.101 | 1.000 | | Resource use, minerals and metals | 1.529e-08 | 1.469e-08 | 1.040 | | Water use | 8.045e-04 | 8.615e-04 | 0.934 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.02096 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 803.8 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, various components for heating system [CH] | 0.03078 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -3.8 / +4.1 | 4.1 (Climate change-Fossil) | | Disposal, multicolumn radiator [CH] | 1.339 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -2.4 / +2.6 | 6.1 (Ionising radiation, human health) | | Disposal, convector radiator [CH] | 0.1455 kg | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.3 / +0.3 | 0.9 (Human toxicity, cancer_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.02096 kg CO2 eq per m2 (95 % interval 0.01835–0.02507). Dominant contributors: Disposal, various components for heating system 59 %; Disposal, multicolumn radiator 37 %; Disposal, convector radiator 4 %. Most sensitive: Disposal, various components for heating system [CH] (-3.8 / +4.1 %); Disposal, multicolumn radiator [CH] (-2.4 / +2.6 %); Disposal, convector radiator [CH] (-0.3 / +0.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m2 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 3/3 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.02096 in [0.01835, 0.02507] | | time period declared | **PASS** | 1994-01/2008-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].