====== Heat, at heat pump, air-water, 15kW, certified electricity, in old building (proj. 210) — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_at_heat_pump_air_water_15kw_certified_electricity_in_old_building_proj_210__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, at heat pump, air-water, 15kW, certified electricity, in old building (proj. 210) [CH], per 1 MJ. EF v3.1 climate change 0.004985 kg CO2 eq (Monte Carlo 95 % interval 0.004044–0.008343). Main contributors: Electricity, low voltage, certified electricity, at grid 30 %; Pentafluoroethane 30 %; Disposal, heat pump, air-water, 15kW 18 %; Heat pump, air-water, 15kW 16 %; Difluoromethane 6 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, at heat pump, air-water, 15kW, certified electricity, in old building (proj. 210) | | Dataset UUID / graph id | ''%%cb3f1eb5-3e2f-3e1d-9bb2-9d6c55f1df3c%%'' / ''%%activity:heat_at_heat_pump_air_water_15kw_certified_electricity_in_old_building_proj_210__ch%%'' | | Reference product, unit | Heat, at heat pump, air-water, 15kW, certified electricity, in old building (proj. 210), 1 MJ | | Location | CH — Data apply to the supply in Switzerland. | | Time period | 9999-01/9999-12 | | Category | heat / heat pumps\heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Heat from a air-water heat pump, 15kW with certified electricity mix (CH). Lifetime of the heating system is 20 years. SPF=2.7. Loss of coolant is 2% (of the total amount in the system) per year.; UUID: cb3f1eb5-3e2f-3e1d-9bb2-9d6c55f1df3c This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, at heat pump, air-water, 15kW, certified electricity, in old building (proj. 210) (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the share of the production of the air-water heatpump with a lifetime of 20years scaled for 1MJ. ==== Technology ==== undefined ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, low voltage, certified electricity, at grid | technosphere | CH | 0.10288 | kWh | lognormal, GSD² 1.22 | — | 29.9 | ██████ | | | Disposal, heat pump, air-water, 15kW | technosphere | CH | 4.4092e-07 | p | lognormal, GSD² 3.05 | — | 17.8 | ████ | | | Heat pump, air-water, 15kW | technosphere | RER | 4.4092e-07 | p | lognormal, GSD² 3.05 | — | 16.3 | ███ | | | Trifluoromethane, at plant | technosphere | GLO | 3.9683e-07 | kg | lognormal, GSD² 2.29 | — | 0.1 | · | | | 1,1-difluoroethane, HFC-152a, at plant | technosphere | US | 3.9683e-07 | kg | lognormal, GSD² 2.29 | — | 0.0 | · | | | Pentafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 3.9683e-07 | kg | lognormal, GSD² 1.56 | — | 29.8 | ██████ | | | Difluoromethane | elementary | air/Ground level / Urban (>1000 people/s… | 3.9683e-07 | kg | lognormal, GSD² 1.56 | — | 6.1 | █ | | | Energy, Geothermal, Converted | elementary | natural resource | 0.62963 | MJ | none declared: tdc-doc default ±50 % | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.37037 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | ==== Data quality ==== 0 of 9 direct exchanges carry a declared pedigree, 8 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Cyrill Kern (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | none | | sampling procedure | heat efficieny based on literature | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 19.02.2021; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme\A_zum konvertieren\WP[EcoSpold_heat at heat pump_ air-water_15-50kW_certified electricity mix_v0.1_lwa.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 1 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.731e-05** | 1.061e-05 | 4.172e-05 | 2.05 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.392e-05** | 6.854e-05 | 1.479e-04 | 1.49 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004807** | 0.003875 | 0.008109 | 1.45 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **8.351e-05** | 5.255e-05 | 1.362e-04 | 1.62 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.004985** | 0.004044 | 0.008343 | 1.43 | | EF-particulate Matter | Impact on human health | disease incidence | **1.299e-10** | 1.018e-10 | 2.953e-10 | 1.74 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01014** | 0.008068 | 0.03381 | 2.05 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.364e-04** | 1.748e-04 | 6.865e-04 | 2.11 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01038** | 0.008258 | 0.03465 | 2.05 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.401e-06** | 1.808e-06 | 6.296e-06 | 1.86 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.540e-06** | 2.881e-06 | 4.778e-05 | 4.03 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.870e-05** | 2.186e-05 | 6.310e-05 | 1.71 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.712e-12** | 1.881e-12 | 9.630e-12 | 2.27 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.366e-12** | 9.992e-13 | 2.859e-12 | 1.72 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.078e-12** | 3.117e-12 | 1.230e-11 | 1.98 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.829e-10** | 1.268e-10 | 7.651e-10 | 2.55 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.338e-11** | 6.975e-12 | 3.726e-11 | 2.42 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.963e-10** | 1.375e-10 | 7.880e-10 | 2.51 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **5.049e-04** | 1.848e-04 | 0.004106 | 4.91 | | Land use | Soil quality index | pt (soil quality index) | **0.05485** | 0.03603 | 0.1029 | 1.73 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.831e-09** | 6.811e-10 | 6.245e-09 | 3.1 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **7.961e-06** | 6.013e-06 | 1.912e-05 | 1.8 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.01987** | 0.01415 | 0.05 | 1.89 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.030e-07** | 1.527e-07 | 9.654e-07 | 2.69 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **2.338e-04** | -3.557 | 1.673 | — | Climate change 0.004985 kg CO2 eq per MJ. Main contributors: Electricity, low voltage, certified electricity, at grid 30 %; Pentafluoroethane 30 %; Disposal, heat pump, air-water, 15kW 18 %; Heat pump, air-water, 15kW 16 %; Difluoromethane 6 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, low voltage, certified electricity, at grid 30 %; Pentafluoroethane 30 %; Disposal, heat pump, air-water, 15kW 18 %; Heat pump, air-water, 15kW 16 %; Difluoromethane 6 %. Most sensitive exchanges (Section 6.3): Disposal, heat pump, air-water, 15kW [CH] (-11.8 / +35.3 %); Heat pump, air-water, 15kW [RER] (-10.8 / +32.2 %); Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-10.5 / +16.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.731e-05 | 1.942e-05 | 0.891 | | Climate change-Biogenic | 9.392e-05 | 9.392e-05 | 1.000 | | Climate change-Fossil | 0.004807 | 0.004807 | 1.000 | | Climate change-Land use and land use change | 8.351e-05 | 8.351e-05 | 1.000 | | Climate change | 0.004985 | 0.004985 | 1.000 | | EF-particulate Matter | 1.299e-10 | 1.299e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.01014 | 0.01062 | 0.955 | | Ecotoxicity, freshwater_organics | 2.364e-04 | 2.241e-04 | 1.055 | | Ecotoxicity, freshwater | 0.01038 | 0.01078 | 0.963 | | Eutrophication marine | 2.401e-06 | 2.401e-06 | 1.000 | | Eutrophication, freshwater | 5.540e-06 | 5.540e-06 | 1.000 | | Eutrophication, terrestrial | 2.870e-05 | 2.864e-05 | 1.002 | | Human toxicity, cancer_inorganics | 2.712e-12 | 2.702e-12 | 1.003 | | Human toxicity, cancer_organics | 1.366e-12 | 1.366e-12 | 1.000 | | Human toxicity, cancer | 4.078e-12 | 4.069e-12 | 1.002 | | Human toxicity, non-cancer_inorganics | 1.829e-10 | 1.823e-10 | 1.003 | | Human toxicity, non-cancer_organics | 1.338e-11 | 1.338e-11 | 1.000 | | Human toxicity, non-cancer | 1.963e-10 | 1.957e-10 | 1.003 | | Ionising radiation, human health | 5.049e-04 | 5.049e-04 | 1.000 | | Land use | 0.05485 | 0.04106 | 1.336 | | Ozone depletion | 1.831e-09 | 1.831e-09 | 1.000 | | Photochemical ozone formation - human health | 7.961e-06 | 7.961e-06 | 1.000 | | Resource use, fossils | 0.01987 | 0.01988 | 1.000 | | Resource use, minerals and metals | 3.030e-07 | 3.025e-07 | 1.002 | | Water use | 2.338e-04 | 2.560e-04 | 0.913 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.004979 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 15.01 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, heat pump, air-water, 15kW [CH] | 4.409e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -11.8 / +35.3 | 36.6 (Climate change-Fossil) | | Heat pump, air-water, 15kW [RER] | 4.409e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -10.8 / +32.2 | 140.5 (Ozone depletion) | | Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 3.968e-07 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -10.5 / +16.3 | 16.9 (Climate change-Fossil) | | Electricity, low voltage, certified electricity, at grid [CH] | 0.1029 kWh | ×0.826 / ×1.21 | lognormal, GSD² 1.22 | -5.2 / +6.3 | 20.9 (Climate change-Land use and land use change) | | Difluoromethane [air/Ground level / Urban (>1000 people/square mile)] | 3.968e-07 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -2.2 / +3.4 | 3.5 (Climate change-Fossil) | | Trifluoromethane, at plant [GLO] | 3.968e-07 kg | ×0.445 / ×2.25 | lognormal, GSD² 2.29 | -0.0 / +0.1 | 34.6 (Ozone depletion) | | 1,1-difluoroethane, HFC-152a, at plant [US] | 3.968e-07 kg | ×0.445 / ×2.25 | lognormal, GSD² 2.29 | -0.0 / +0.0 | 0.2 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.004985 kg CO2 eq per MJ (95 % interval 0.004044–0.008343). Dominant contributors: Electricity, low voltage, certified electricity, at grid 30 %; Pentafluoroethane 30 %; Disposal, heat pump, air-water, 15kW 18 %; Heat pump, air-water, 15kW 16 %; Difluoromethane 6 %. Most sensitive: Disposal, heat pump, air-water, 15kW [CH] (-11.8 / +35.3 %); Heat pump, air-water, 15kW [RER] (-10.8 / +32.2 %); Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] (-10.5 / +16.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.6e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/9 exchanges carry a distribution (89 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.004985 in [0.004044, 0.008343] | | time period declared | **PASS** | 9999-01/9999-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].