====== Sewer system, PVC pipe, DN 300, profile 1 — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:sewer_system_pvc_pipe_dn_300_profile_1__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Sewer system, PVC pipe, DN 300, profile 1 [CH], per 1 m. EF v3.1 climate change 405.4 kg CO2 eq (Monte Carlo 95 % interval 220.7–1114). Main contributors: Disposal, sewer system, PVC pipe, DN 300, profile 1 51 %; Sewer system, construction, PVC pipe, DN 300, profile 1 49 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Sewer system, PVC pipe, DN 300, profile 1 | | Dataset UUID / graph id | ''%%cbd06e6c-b633-40c5-9499-0bf1d54adc85%%'' / ''%%activity:sewer_system_pvc_pipe_dn_300_profile_1__ch%%'' | | Reference product, unit | Sewer system, PVC pipe, DN 300, profile 1, 1 m | | Location | CH — Switzerland | | Time period | / | | Category | construction / infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Modern Swiss und European technologies are applied to building machines, material production and building processes. UUID: cbd06e6c-b633-40c5-9499-0bf1d54adc85 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m** of Sewer system, PVC pipe, DN 300, profile 1 (CH). All results are given per unit of the reference flow. ==== System boundary ==== This process models 1 meter of sewer system infrastructure with PVC-pipe, DN 300, SN 4-8, profile 1 according to SIA 190. Trench depth: 3 meters. This process includes the production phase (A1–A3), the construction phase/ transport (A4–A5) as well as deconstruction phase (C1), transport phase (C2), treatment/ recycling phase (C3), and final disposal phase (C4) for one meter of sewer system with PVC-pipe. ==== Technology ==== Complete sewer system, DN 300, SN 4-8, profile 1 according to SIA 190.Trench depth 3 meters. PVC-pipe, ID 291-296 mm, outer diameter 315 mm, wall thickness 9-11 mm, 12-15 kg/m, 910-1400 kg/m³. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, sewer system, PVC pipe, DN 300, profile 1 | technosphere | CH | 1 | m | lognormal, GSD² 3.05 | — | 51.1 | ██████████ | | | Sewer system, construction, PVC pipe, DN 300, profile 1 | technosphere | CH | 1 | m | lognormal, GSD² 3.02 | — | 48.9 | ██████████ | | ==== Data quality ==== 0 of 2 direct exchanges carry a declared pedigree, 2 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Pohl (UMTEC); data entry: Thomas Pohl (UMTEC); validation (proof reading): Cornelia Stettler (CARBOTECH) | | extrapolations | | | uncertainty adjustments | | | time period comment | Review of data currency scheduled after 5 years. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.9781** | 0.5397 | 2.636 | 2.29 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.5037** | 0.2721 | 1.651 | 2.51 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **404.3** | 220 | 1111 | 2.31 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.564** | 0.2698 | 1.544 | 2.52 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **405.4** | 220.7 | 1114 | 2.31 | | EF-particulate Matter | Impact on human health | disease incidence | **4.524e-05** | 1.960e-05 | 1.574e-04 | 2.98 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1160** | 719.6 | 4720 | 2.67 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **62.27** | 34.83 | 182.4 | 2.4 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1222** | 758.3 | 4928 | 2.64 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.6069** | 0.3253 | 1.785 | 2.42 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.1253** | 0.03986 | 3.789 | 10.5 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **5.325** | 2.879 | 14.51 | 2.33 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.836e-08** | 3.067e-08 | 1.764e-07 | 2.49 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.833e-08** | 4.143e-08 | 2.512e-07 | 2.47 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.167e-07** | 7.695e-08 | 4.040e-07 | 2.37 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.245e-06** | 1.613e-06 | 9.081e-06 | 2.46 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.671e-07** | 3.262e-07 | 2.179e-06 | 2.6 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.912e-06** | 2.038e-06 | 1.081e-05 | 2.41 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **56.5** | 19.03 | 415.5 | 4.87 | | Land use | Soil quality index | pt (soil quality index) | **2779** | 1041 | 8197 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.029e-05** | 9.819e-06 | 6.444e-05 | 2.58 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.118** | 1.155 | 6.217 | 2.35 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **5237** | 2882 | 1.445e+04 | 2.31 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **7.281e-04** | 4.071e-04 | 0.002439 | 2.52 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **23.4** | -3.759e+04 | 2.145e+04 | — | Climate change 405.4 kg CO2 eq per m. Main contributors: Disposal, sewer system, PVC pipe, DN 300, profile 1 51 %; Sewer system, construction, PVC pipe, DN 300, profile 1 49 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, sewer system, PVC pipe, DN 300, profile 1 51 %; Sewer system, construction, PVC pipe, DN 300, profile 1 49 %. Most sensitive exchanges (Section 6.3): Disposal, sewer system, PVC pipe, DN 300, profile 1 [CH] (-34.0 / +101.4 %); Sewer system, construction, PVC pipe, DN 300, profile 1 [CH] (-32.3 / +95.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.9781 | 1.343 | 0.728 | | Climate change-Biogenic | 0.5037 | 0.5037 | 1.000 | | Climate change-Fossil | 404.3 | 404.3 | 1.000 | | Climate change-Land use and land use change | 0.564 | 0.564 | 1.000 | | Climate change | 405.4 | 405.4 | 1.000 | | EF-particulate Matter | 4.524e-05 | 4.524e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1160 | 1166 | 0.995 | | Ecotoxicity, freshwater_organics | 62.27 | 62.13 | 1.002 | | Ecotoxicity, freshwater | 1222 | 1227 | 0.996 | | Eutrophication marine | 0.6069 | 0.6069 | 1.000 | | Eutrophication, freshwater | 0.1253 | 0.1253 | 1.000 | | Eutrophication, terrestrial | 5.325 | 5.984 | 0.890 | | Human toxicity, cancer_inorganics | 3.836e-08 | 3.799e-08 | 1.010 | | Human toxicity, cancer_organics | 7.833e-08 | 7.833e-08 | 1.000 | | Human toxicity, cancer | 1.167e-07 | 1.163e-07 | 1.003 | | Human toxicity, non-cancer_inorganics | 2.245e-06 | 2.229e-06 | 1.007 | | Human toxicity, non-cancer_organics | 6.671e-07 | 6.671e-07 | 1.000 | | Human toxicity, non-cancer | 2.912e-06 | 2.897e-06 | 1.005 | | Ionising radiation, human health | 56.5 | 56.5 | 1.000 | | Land use | 2779 | 1749 | 1.589 | | Ozone depletion | 2.029e-05 | 2.029e-05 | 1.000 | | Photochemical ozone formation - human health | 2.118 | 2.118 | 1.000 | | Resource use, fossils | 5237 | 5237 | 1.000 | | Resource use, minerals and metals | 7.281e-04 | 4.698e-04 | 1.550 | | Water use | 23.4 | 45.19 | 0.518 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 405.4 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.013e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, sewer system, PVC pipe, DN 300, profile 1 [CH] | 1 m | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -34.0 / +101.4 | 179.2 (EF-particulate Matter) | | Sewer system, construction, PVC pipe, DN 300, profile 1 [CH] | 1 m | ×0.339 / ×2.95 | lognormal, GSD² 3.02 | -32.3 / +95.3 | 141.9 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 405.4 kg CO2 eq per m (95 % interval 220.7–1114). Dominant contributors: Disposal, sewer system, PVC pipe, DN 300, profile 1 51 %; Sewer system, construction, PVC pipe, DN 300, profile 1 49 %. Most sensitive: Disposal, sewer system, PVC pipe, DN 300, profile 1 [CH] (-34.0 / +101.4 %); Sewer system, construction, PVC pipe, DN 300, profile 1 [CH] (-32.3 / +95.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 2/2 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 405.4 in [220.7, 1114] | | time period declared | **PASS** | / | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Report — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].