====== Electricity, high voltage, production from hydro power FR, at grid — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_high_voltage_production_from_hydro_power_fr_at_grid__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, high voltage, production from hydro power FR, at grid [CH], per 1 kWh. EF v3.1 climate change 0.008364 kg CO2 eq (Monte Carlo 95 % interval 0.005781–0.01911). Main contributors: Electricity, hydropower, at run-of-river power plant 39 %; Electricity, hydropower, at reservoir power plant, non alpin… 32 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, high voltage, production from hydro power FR, at grid | | Dataset UUID / graph id | ''%%cc58d5b5-69ae-33e9-bb9b-cd4c7db066eb%%'' / ''%%activity:electricity_high_voltage_production_from_hydro_power_fr_at_grid__ch%%'' | | Reference product, unit | Electricity, high voltage, production from hydro power FR, at grid, 1 kWh | | Location | CH — Data apply to public and self producers. Geographical classification according to IEA. Ozone- and NO2-emission factors are based on published measurements made in various countries. Assumptions for transmission network, losses and emissions are based on Swiss data. | | Time period | 2004-01/2004-12 | | Category | energy supply, kbob recommendation / electricity, delivered via network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transmission of high voltage electricity.; UUID: cc58d5b5-69ae-33e9-bb9b-cd4c7db066eb This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, high voltage, production from hydro power FR, at grid (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in CENTREL-countries, the transmission network and direct emissions to air (ozone and N2O). Electricity losses are accounted for. ==== Technology ==== Average technology used to transmit and distribute electricity. Includes underground and overhead lines. Electricity production according to related datasets ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, hydropower, at run-of-river power plant | technosphere | RER | 0.86774 | kWh | lognormal, GSD² 1.24 | (3,1,1,1,3,1) | 38.7 | ████████ | | | Electricity, hydropower, at reservoir power plant, non alpine regions | technosphere | RER | 0.16528 | kWh | lognormal, GSD² 1.24 | (3,1,1,1,3,1) | 32.0 | ██████ | | | Transmission network, electricity, high voltage | technosphere | CH | 6.8199e-09 | km | lognormal, GSD² 3.16 | (3,1,4,5,3,5) | 12.9 | ███ | | | Nitrous Oxide | elementary | air/Unknown | 5.0000e-06 | kg | lognormal, GSD² 1.5 | — | 16.3 | ███ | | | Waste Heat | elementary | soil/Unknown | 0.0059435 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | | Ozone | elementary | air/Unknown | 4.5000e-06 | kg | lognormal, GSD² 1.5 | — | 0.0 | · | | | Waste Heat | elementary | air/Unknown | 0.11293 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 5 of 7 direct exchanges carry a declared pedigree, 7 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.4 · completeness 1.0 · temporal 2.4 · geographical 1.8 · technological 2.2 · sample size 3.4. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Tuchschmid; data entry: Matthias Tuchschmid; validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | statistics | | production volume | total electricity in Switzerland: 37 TWh | | uncertainty adjustments | none | | validation details | Proof reading validation: automatic validation in Excel; Other validation: none; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **1.268e-05** | 6.751e-06 | 3.964e-05 | 2.43 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.336e-04** | 3.123e-04 | 9.927e-04 | 1.8 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.006041** | 0.003652 | 0.01653 | 2.13 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.00179** | 8.069e-04 | 0.004233 | 2.29 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.008364** | 0.005781 | 0.01911 | 1.83 | | EF-particulate Matter | Impact on human health | disease incidence | **3.407e-10** | 1.720e-10 | 1.269e-09 | 2.77 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008498** | 0.005049 | 0.03555 | 2.67 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.769e-04** | 2.305e-04 | 0.001584 | 2.71 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008875** | 0.005263 | 0.03722 | 2.65 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.786e-06** | 1.959e-06 | 1.247e-05 | 2.59 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.576e-06** | 1.416e-06 | 2.551e-05 | 4.58 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **3.622e-05** | 1.876e-05 | 1.185e-04 | 2.58 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.924e-12** | 1.241e-12 | 9.057e-12 | 2.72 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.256e-12** | 6.506e-13 | 4.279e-12 | 2.63 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.179e-12** | 1.935e-12 | 1.326e-11 | 2.61 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.067e-10** | 7.349e-11 | 4.634e-10 | 2.66 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.518e-12** | 4.309e-12 | 2.422e-11 | 2.41 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.142e-10** | 7.783e-11 | 4.876e-10 | 2.63 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **9.586e-04** | 3.115e-04 | 0.007583 | 5.38 | | Land use | Soil quality index | pt (soil quality index) | **-0.0959** | -0.326 | 0.001715 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **5.119e-11** | 2.861e-11 | 1.796e-10 | 2.6 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.456e-05** | 7.821e-06 | 4.997e-05 | 2.58 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.03948** | 0.02063 | 0.129 | 2.55 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **6.199e-08** | 3.011e-08 | 1.880e-07 | 2.65 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **2.493e-04** | -2445 | 1198 | — | Climate change 0.008364 kg CO2 eq per kWh. Main contributors: Electricity, hydropower, at run-of-river power plant 39 %; Electricity, hydropower, at reservoir power plant, non alpin… 32 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, hydropower, at run-of-river power plant 39 %; Electricity, hydropower, at reservoir power plant, non alpin… 32 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. Most sensitive exchanges (Section 6.3): Transmission network, electricity, high voltage [CH] (-8.8 / +27.1 %); Electricity, hydropower, at run-of-river power plant [RER] (-7.2 / +8.9 %); Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-6.0 / +7.4 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 1.268e-05 | 1.607e-05 | 0.789 | | Climate change-Biogenic | 5.336e-04 | 5.336e-04 | 1.000 | | Climate change-Fossil | 0.006041 | 0.006041 | 1.000 | | Climate change-Land use and land use change | 0.00179 | 0.00179 | 1.000 | | Climate change | 0.008364 | 0.008364 | 1.000 | | EF-particulate Matter | 3.407e-10 | 3.407e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.008498 | 0.00884 | 0.961 | | Ecotoxicity, freshwater_organics | 3.769e-04 | 3.759e-04 | 1.003 | | Ecotoxicity, freshwater | 0.008875 | 0.009206 | 0.964 | | Eutrophication marine | 3.786e-06 | 3.786e-06 | 1.000 | | Eutrophication, freshwater | 2.576e-06 | 2.576e-06 | 1.000 | | Eutrophication, terrestrial | 3.622e-05 | 4.068e-05 | 0.890 | | Human toxicity, cancer_inorganics | 1.924e-12 | 1.911e-12 | 1.007 | | Human toxicity, cancer_organics | 1.256e-12 | 1.256e-12 | 1.000 | | Human toxicity, cancer | 3.179e-12 | 3.166e-12 | 1.004 | | Human toxicity, non-cancer_inorganics | 1.067e-10 | 1.062e-10 | 1.004 | | Human toxicity, non-cancer_organics | 7.518e-12 | 7.518e-12 | 1.000 | | Human toxicity, non-cancer | 1.142e-10 | 1.137e-10 | 1.004 | | Ionising radiation, human health | 9.586e-04 | 9.586e-04 | 1.000 | | Land use | -0.0959 | -0.1032 | 0.929 | | Ozone depletion | 5.119e-11 | 5.119e-11 | 1.000 | | Photochemical ozone formation - human health | 1.456e-05 | 1.456e-05 | 1.000 | | Resource use, fossils | 0.03948 | 0.0395 | 1.000 | | Resource use, minerals and metals | 6.199e-08 | 6.174e-08 | 1.004 | | Water use | 2.493e-04 | 3.445e-04 | 0.724 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.008363 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 28.48 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Transmission network, electricity, high voltage [CH] | 6.820e-09 km | ×0.324 / ×3.09 | lognormal, GSD² 3.16 | -8.8 / +27.1 | 121.8 (Resource use, minerals and metals) | | Electricity, hydropower, at run-of-river power plant [RER] | 0.8677 kWh | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -7.2 / +8.9 | 16.1 (Ecotoxicity, freshwater_organics) | | Electricity, hydropower, at reservoir power plant, non alpine regions [RER] | 0.1653 kWh | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -6.0 / +7.4 | 25.2 (Land use) | | Nitrous Oxide [air/Unknown] | 5.000e-06 kg | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -5.4 / +8.0 | 11.0 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.008364 kg CO2 eq per kWh (95 % interval 0.005781–0.01911). Dominant contributors: Electricity, hydropower, at run-of-river power plant 39 %; Electricity, hydropower, at reservoir power plant, non alpin… 32 %; Nitrous Oxide 16 %; Transmission network, electricity, high voltage 13 %. Most sensitive: Transmission network, electricity, high voltage [CH] (-8.8 / +27.1 %); Electricity, hydropower, at run-of-river power plant [RER] (-7.2 / +8.9 %); Electricity, hydropower, at reservoir power plant, non alpine regions [RER] (-6.0 / +7.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.1e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 7/7 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.008364 in [0.005781, 0.01911] | | time period declared | **PASS** | 2004-01/2004-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht, R., Tuchschmid, M., Faist Emmenegger, M.,Bauer, C., Dones, R. (2007) Strommix und Stromnetz. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Frischknecht, R. Other authors: Tuchschmid, M., Faist Emmenegger, M.,Bauer, C.,… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].