====== Printed wiring board, mounted, Laptop PC mainboard, Pb containing, at plant — GLO ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:printed_wiring_board_mounted_laptop_pc_mainboard_pb_containing_at_plant__glo|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Printed wiring board, mounted, Laptop PC mainboard, Pb containing, at plant [GLO], per 1 kg. EF v3.1 climate change 172 kg CO2 eq (Monte Carlo 95 % interval 153.5–226.7). Main contributors: Integrated circuit, IC, logic type, at plant 51 %; Integrated circuit, IC, memory type, at plant 22 %; Printed wiring board, surface mount, lead-containing surface… 22 %; Resistor, SMD type, surface mounting, at plant 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Printed wiring board, mounted, Laptop PC mainboard, Pb containing, at plant | | Dataset UUID / graph id | ''%%ce163547-60a6-3e54-97fb-cffa592242e5%%'' / ''%%activity:printed_wiring_board_mounted_laptop_pc_mainboard_pb_containing_at_plant__glo%%'' | | Reference product, unit | Printed wiring board, mounted, Laptop PC mainboard, Pb containing, at plant, 1 kg | | Location | GLO | | Time period | 2004-01/2004-12 | | Category | electronics / devices\module\pwb | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The data represent a typical Lsptop PC mainboard, used in modern computers. Material data are taken from the literature plus from own estimations and assumptions. Infrastructure and production efforts are based on own assumptions.; UUID: ce163547-60a6-3e54-97fb-cffa592242e5 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Printed wiring board, mounted, Laptop PC mainboard, Pb containing, at plant (GLO). All results are given per unit of the reference flow. ==== System boundary ==== This dataset covers component input and production efforts (incl. PWB waste due to failure in mounting) for the production of Laptop PC mainboards, using Pb-containing solder material. ==== Technology ==== average PWB mounting technology (solder paste production line) ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Integrated circuit, IC, logic type, at plant | technosphere | GLO | 0.1449 | kg | lognormal, GSD² 1.24 | — | 50.7 | ██████████ | | | Integrated circuit, IC, memory type, at plant | technosphere | GLO | 0.10816 | kg | lognormal, GSD² 1.24 | — | 21.8 | ████ | | | Printed wiring board, surface mount, lead-containing surface, at plant | technosphere | GLO | 0.19407 | m2 | lognormal, GSD² 1.22 | — | 21.5 | ████ | | | Resistor, SMD type, surface mounting, at plant | technosphere | GLO | 0.019388 | kg | lognormal, GSD² 1.24 | — | 1.8 | · | | | Connector, PCI bus, at plant | technosphere | GLO | 0.032653 | kg | lognormal, GSD² 1.24 | — | 1.0 | · | | | Capacitor, SMD type, surface-mounting, at plant | technosphere | GLO | 0.027551 | kg | lognormal, GSD² 1.24 | — | 0.8 | · | | | Mounting, through-hole technology, Pb-containing solder | technosphere | GLO | 0.02911 | m2 | lognormal, GSD² 1.24 | — | 0.7 | · | | | Transistor, SMD type, surface mounting, at plant | technosphere | GLO | 0.0081633 | kg | lognormal, GSD² 1.24 | — | 0.7 | · | | | Diode, glass-, SMD type, surface mounting, at plant | technosphere | GLO | 0.0030612 | kg | lognormal, GSD² 1.24 | — | 0.3 | · | | | Mounting, surface mount technology, Pb-containing solder | technosphere | GLO | 0.16496 | m2 | lognormal, GSD² 1.24 | — | 0.3 | · | | | Connector, computer, peripherical type, at plant | technosphere | GLO | 0.043878 | kg | lognormal, GSD² 1.24 | — | 0.2 | · | | | Light emitting diode, LED, at plant | technosphere | GLO | 0.0010204 | kg | lognormal, GSD² 1.24 | — | 0.1 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 0.13265 | tkm | lognormal, GSD² 2.1 | — | 0.0 | · | | | Transport, transoceanic freight ship | technosphere | OCE | 0.80612 | tkm | lognormal, GSD² 2.1 | — | 0.0 | · | | | Transport, freight, rail | technosphere | RER | 0.14286 | tkm | lognormal, GSD² 2.1 | — | 0.0 | · | | | Disposal, treatment of printed wiring boards | technosphere | GLO | 0.020408 | kg | lognormal, GSD² 1.24 | — | 0.0 | · | | ==== Data quality ==== 0 of 16 direct exchanges carry a declared pedigree, 16 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Roland Hischier (EMPA); data entry: Roland Hischier (EMPA); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | see Geography & Technology | | sampling procedure | literature & own estimations | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: passed.; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.7198** | 0.645 | 1.014 | 1.26 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.034** | 0.5813 | 2.731 | 2.2 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **170.9** | 152.6 | 225.3 | 1.22 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.07056** | 0.05946 | 0.106 | 1.35 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **172** | 153.5 | 226.7 | 1.22 | | EF-particulate Matter | Impact on human health | disease incidence | **5.609e-06** | 5.136e-06 | 8.939e-06 | 1.34 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1452** | 1373 | 3079 | 1.58 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **32.14** | 27.82 | 48.97 | 1.35 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1484** | 1411 | 3113 | 1.57 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.2531** | 0.214 | 0.4644 | 1.52 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.025** | 0.594 | 6.736 | 3.43 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.23** | 1.814 | 3.52 | 1.41 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.042e-07** | 1.877e-07 | 6.413e-07 | 1.92 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.881e-08** | 5.792e-08 | 1.020e-07 | 1.35 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.730e-07** | 2.554e-07 | 7.156e-07 | 1.73 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.462e-05** | 1.144e-05 | 5.311e-05 | 2.18 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.532e-07** | 2.114e-07 | 3.913e-07 | 1.38 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.487e-05** | 1.174e-05 | 5.344e-05 | 2.16 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **52.64** | 17.38 | 328.1 | 4.57 | | Land use | Soil quality index | pt (soil quality index) | **1537** | 1059 | 2885 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **2.069e-05** | 1.572e-05 | 3.197e-05 | 1.44 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.6935** | 0.6018 | 1.039 | 1.31 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **2385** | 2113 | 3476 | 1.28 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.1569** | 0.1248 | 0.2125 | 1.31 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **33.88** | -4.689e+04 | 2.436e+04 | — | Climate change 172 kg CO2 eq per kg. Main contributors: Integrated circuit, IC, logic type, at plant 51 %; Integrated circuit, IC, memory type, at plant 22 %; Printed wiring board, surface mount, lead-containing surface… 22 %; Resistor, SMD type, surface mounting, at plant 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Integrated circuit, IC, logic type, at plant 51 %; Integrated circuit, IC, memory type, at plant 22 %; Printed wiring board, surface mount, lead-containing surface… 22 %; Resistor, SMD type, surface mounting, at plant 2 %. Most sensitive exchanges (Section 6.3): Integrated circuit, IC, logic type, at plant [GLO] (-9.8 / +12.1 %); Integrated circuit, IC, memory type, at plant [GLO] (-4.2 / +5.2 %); Printed wiring board, surface mount, lead-containing surface, at plant [GLO] (-3.8 / +4.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.7198 | 1.369 | 0.526 | | Climate change-Biogenic | 1.034 | 1.034 | 1.000 | | Climate change-Fossil | 170.9 | 170.9 | 1.000 | | Climate change-Land use and land use change | 0.07056 | 0.07056 | 1.000 | | Climate change | 172 | 172 | 1.000 | | EF-particulate Matter | 5.609e-06 | 5.609e-06 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1452 | 1495 | 0.971 | | Ecotoxicity, freshwater_organics | 32.14 | 25.67 | 1.252 | | Ecotoxicity, freshwater | 1484 | 1468 | 1.011 | | Eutrophication marine | 0.2531 | 0.253 | 1.000 | | Eutrophication, freshwater | 1.025 | 1.025 | 1.000 | | Eutrophication, terrestrial | 2.23 | 2.37 | 0.941 | | Human toxicity, cancer_inorganics | 2.042e-07 | 2.023e-07 | 1.009 | | Human toxicity, cancer_organics | 6.881e-08 | 6.881e-08 | 1.000 | | Human toxicity, cancer | 2.730e-07 | 2.711e-07 | 1.007 | | Human toxicity, non-cancer_inorganics | 1.462e-05 | 1.445e-05 | 1.012 | | Human toxicity, non-cancer_organics | 2.532e-07 | 2.532e-07 | 1.000 | | Human toxicity, non-cancer | 1.487e-05 | 1.470e-05 | 1.012 | | Ionising radiation, human health | 52.64 | 52.64 | 1.000 | | Land use | 1537 | 1350 | 1.138 | | Ozone depletion | 2.069e-05 | 2.069e-05 | 1.000 | | Photochemical ozone formation - human health | 0.6935 | 0.6935 | 1.000 | | Resource use, fossils | 2385 | 2387 | 0.999 | | Resource use, minerals and metals | 0.1569 | 0.1567 | 1.001 | | Water use | 33.88 | 39.96 | 0.848 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 172 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 9.827e+05 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Integrated circuit, IC, logic type, at plant [GLO] | 0.1449 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -9.8 / +12.1 | 14.0 (Resource use, minerals and metals) | | Integrated circuit, IC, memory type, at plant [GLO] | 0.1082 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -4.2 / +5.2 | 8.0 (Ozone depletion) | | Printed wiring board, surface mount, lead-containing surface, at plant [GLO] | 0.1941 m2 | ×0.825 / ×1.21 | lognormal, GSD² 1.22 | -3.8 / +4.6 | 10.9 (Ionising radiation, human health) | | Resistor, SMD type, surface mounting, at plant [GLO] | 0.01939 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.3 / +0.4 | 1.4 (EF-particulate Matter) | | Connector, PCI bus, at plant [GLO] | 0.03265 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.2 / +0.2 | 0.6 (Resource use, minerals and metals) | | Capacitor, SMD type, surface-mounting, at plant [GLO] | 0.02755 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.2 / +0.2 | 1.3 (Human toxicity, non-cancer_organics) | | Mounting, through-hole technology, Pb-containing solder [GLO] | 0.02911 m2 | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.1 / +0.2 | 0.7 (Ionising radiation, human health) | | Transistor, SMD type, surface mounting, at plant [GLO] | 0.008163 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.1 / +0.2 | 0.3 (Climate change-Land use and land use change) | | Diode, glass-, SMD type, surface mounting, at plant [GLO] | 0.003061 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.1 (Climate change-Land use and land use change) | | Mounting, surface mount technology, Pb-containing solder [GLO] | 0.165 m2 | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 5.1 (Human toxicity, cancer_organics) | | Connector, computer, peripherical type, at plant [GLO] | 0.04388 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.3 (Human toxicity, non-cancer_organics) | | Light emitting diode, LED, at plant [GLO] | 0.00102 kg | ×0.808 / ×1.24 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.0 (Climate change-Land use and land use change) | | Transport, freight, lorry, fleet average [RER] | 0.1326 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.0 | 0.1 (Climate change-Land use and land use change) | | Transport, transoceanic freight ship [OCE] | 0.8061 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.0 | 0.0 (Acidification) | | Transport, freight, rail [RER] | 0.1429 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.0 | 0.0 (Land use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 172 kg CO2 eq per kg (95 % interval 153.5–226.7). Dominant contributors: Integrated circuit, IC, logic type, at plant 51 %; Integrated circuit, IC, memory type, at plant 22 %; Printed wiring board, surface mount, lead-containing surface… 22 %; Resistor, SMD type, surface mounting, at plant 2 %. Most sensitive: Integrated circuit, IC, logic type, at plant [GLO] (-9.8 / +12.1 %); Integrated circuit, IC, memory type, at plant [GLO] (-4.2 / +5.2 %); Printed wiring board, surface mount, lead-containing surface, at plant [GLO] (-3.8 / +4.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.3e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 16/16 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 172 in [153.5, 226.7] | | time period declared | **PASS** | 2004-01/2004-12 | | geography is a known location code | **PASS** | GLO | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Hischier R., Classen M., Lehmann M., Scharnhorst W. (2007) Life Cycle Inventories of Electric and Electronic Equipment - Production, Use & Disposal. Final report ecoinvent Data v2.0. Volume: 18. Swiss Centre for LCI, Empa - TSL. Duebendorf and St. Gallen, CH. Type: Measurement on site Source: CD-ROM First author: Hischier R. Other authors: Classen M., Lehmann M., Scharnhorst W. Year: 2007 Title of… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].