====== Heat, at nuclear power plant, economic allocation — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_at_nuclear_power_plant_economic_allocation__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, at nuclear power plant, economic allocation [CH], per 1 MJ. EF v3.1 climate change 3.403e-05 kg CO2 eq (Monte Carlo 95 % interval 2.846e-05–4.756e-05). Main contributors: U enriched 4.75%, in fuel element for LWR, at nuclear fuel f… 90 %; Nuclear power plant, pressure water reactor 1000MW 5 %; Nuclear spent fuel, in reprocessing, at plant 2 %; Nuclear spent fuel, in conditioning, at plant 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, at nuclear power plant, economic allocation | | Dataset UUID / graph id | ''%%cff77537-4513-397d-9082-d0feceb42d77%%'' / ''%%activity:heat_at_nuclear_power_plant_economic_allocation__ch%%'' | | Reference product, unit | Heat, at nuclear power plant, economic allocation, 1 MJ | | Location | CH — Data apply to the supply in Switzerland. | | Time period | 2019-01/2020-12 | | Category | heat / nuclear power\district heat | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Inventory for 1 MJ heat from nuclear power plant. In 2019, of the total energy produced were 97.8% as electricity and 2.2% as heat. The economic factor is 0.72 for ectricity and 0.28 for heat. This leads to the allocation factor of 0.991 for electricity an 0.009 for heat.; UUID: cff77537-4513-397d-9082-d0feceb42d77 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, at nuclear power plant, economic allocation (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included is the demnd of materials, energy, infrastructures and transports for the production of heat at a nuclear power plant ==== Technology ==== average technology ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | U enriched 4.75%, in fuel element for LWR, at nuclear fuel fabrication plant | technosphere | CH | 5.3491e-09 | kg | lognormal, GSD² 1.22 | — | 89.8 | ██████████████████ | | | Nuclear power plant, pressure water reactor 1000MW | technosphere | CH | 6.3598e-15 | p | lognormal, GSD² 3.05 | — | 5.5 | █ | | | Nuclear spent fuel, in reprocessing, at plant | technosphere | RER | 2.4256e-09 | kg | lognormal, GSD² 1.22 | — | 2.1 | · | | | Nuclear spent fuel, in conditioning, at plant | technosphere | CH | 3.6483e-09 | kg | lognormal, GSD² 1.22 | — | 1.2 | · | | | Radioactive waste, in final repository for nuclear waste LLW | technosphere | CH | 7.0007e-11 | m3 | lognormal, GSD² 1.22 | — | 0.3 | · | | | Diesel, burned in diesel-electric generating set | technosphere | GLO | 9.1206e-07 | MJ | lognormal, GSD² 1.22 | — | 0.3 | · | | | Water, decarbonised, at plant | technosphere | RER | 0.0066063 | kg | lognormal, GSD² 1.22 | — | 0.1 | · | | | Hydrogen, liquid, at plant | technosphere | RER | 2.5390e-08 | kg | lognormal, GSD² 1.22 | — | 0.1 | · | | | Nitrogen, liquid, at plant | technosphere | RER | 1.5209e-07 | kg | lognormal, GSD² 1.22 | — | 0.1 | · | | | Sodium hypochlorite, 15% in H2O, at plant | technosphere | RER | 4.2645e-08 | kg | lognormal, GSD² 1.22 | — | 0.1 | · | | | Disposal, separator sludge, 90% water, to hazardous waste incineration | technosphere | CH | 5.3984e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Flat glass, coated, at plant | technosphere | RER | 1.0772e-08 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Disposal, used mineral oil, 10% water, to hazardous waste incineration | technosphere | CH | 4.0180e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Radioactive waste, in interim storage, for final repository LLW | technosphere | CH | 4.3385e-12 | m3 | lognormal, GSD² 1.22 | — | 0.0 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 6.4091e-08 | tkm | lognormal, GSD² 2.05 | — | 0.0 | · | | | Argon, liquid, at plant | technosphere | RER | 6.4337e-08 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Chemicals inorganic, at plant | technosphere | GLO | 5.7682e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Oxygen, liquid, at plant | technosphere | RER | 4.1166e-08 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Steel, low-alloyed, at plant | technosphere | RER | 3.9441e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Radioactive waste, in interim storage conditioning | technosphere | CH | 1.0649e-13 | m3 | lognormal, GSD² 1.22 | — | 0.0 | · | | | Chemicals organic, at plant | technosphere | GLO | 3.4018e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Disposal, hazardous waste, 25% water, to hazardous waste incineration | technosphere | CH | 2.3911e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Concrete, normal, at plant | technosphere | CH | 2.4009e-11 | m3 | lognormal, GSD² 1.22 | — | 0.0 | · | | | Lubricating oil, at plant | technosphere | RER | 3.9934e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Transport, freight, lorry, fleet average | technosphere | RER | 1.9030e-08 | tkm | lognormal, GSD² 2.05 | — | 0.0 | · | | | Bitumen, at refinery | technosphere | CH | 1.9005e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Paper, woodfree, coated, at integrated mill | technosphere | RER | 1.5850e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Reinforcing steel, at plant | technosphere | RER | 1.1586e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Cement, unspecified, at plant | technosphere | CH | 2.2654e-09 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Anionic resin, at plant | technosphere | CH | 1.5850e-10 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Cast iron, at plant | technosphere | RER | 3.1799e-10 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Carbon dioxide liquid, at plant | technosphere | RER | 4.1166e-10 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Cationic resin, at plant | technosphere | CH | 1.5850e-10 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Acetylene, at regional storehouse | technosphere | CH | 8.8741e-11 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Boric acid, anhydrous, powder, at plant | technosphere | RER | 1.5850e-10 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Antimony-125 | elementary | water/River | 1.0279e-07 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cesium-137 | elementary | air/Medium stack, <150 meters / Rural (<… | 1.7945e-11 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Technetium-99m | elementary | water/River | 6.9268e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Xenon-135 | elementary | air/Medium stack, <150 meters / Rural (<… | 4.0920e-04 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Antimony-124 | elementary | water/River | 1.0181e-07 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Molybdenum-99 | elementary | water/River | 1.4790e-11 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Antimony-124 | elementary | air/Medium stack, <150 meters / Rural (<… | 1.1709e-12 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Aerosols, Radioactive, Unspecified | elementary | air/Medium stack, <150 meters / Rural (<… | 1.3237e-11 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Carbon-14 | elementary | air/Medium stack, <150 meters / Rural (<… | 1.8833e-05 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Iodine-133 | elementary | air/Medium stack, <150 meters / Rural (<… | 4.4864e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Iron-59 | elementary | water/River | 1.0353e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cerium-141 | elementary | water/River | 4.3385e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cobalt-58 | elementary | air/Medium stack, <150 meters / Rural (<… | 4.0427e-11 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Niobium-95 | elementary | water/River | 7.5677e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cesium-134 | elementary | water/River | 9.2932e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Ruthenium-103 | elementary | water/River | 7.0254e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Manganese-54 | elementary | water/River | 3.2292e-08 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Xenon-133 | elementary | air/Medium stack, <150 meters / Rural (<… | 0.0014889 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Radioactive Species, Other Beta Emitters | elementary | air/Medium stack, <150 meters / Rural (<… | 2.1372e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Zirconium-95 | elementary | air/Medium stack, <150 meters / Rural (<… | 1.4248e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Antimony-122 | elementary | water/River | 2.2284e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Strontium-89 | elementary | water/River | 8.9974e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Hydrogen-3 | elementary | water/River | 0.004585 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Zinc-65 | elementary | water/River | 6.4830e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Noble Gases, Radioactive, Unspecified | elementary | air/Medium stack, <150 meters / Rural (<… | 6.3844e-04 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Radioactive Species, Alpha Emitters | elementary | water/Surface water | 7.4444e-11 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cobalt-57 | elementary | water/River | 2.1988e-08 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Lanthanum-140 | elementary | water/River | 1.2202e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Strontium-90 | elementary | water/River | 3.2045e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cerium-144 | elementary | water/River | 1.1881e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Silver-110m | elementary | water/River | 1.0920e-08 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Sodium-24 | elementary | water/River | 2.4601e-08 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Chromium-51 | elementary | water/River | 1.8636e-08 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | River water, CH | elementary | natural resource/River [CH] | 1.4174e-05 | m3 | lognormal, GSD² 1.22 | — | 0.0 | · | | | Waste Heat | elementary | air/Medium stack, <150 meters / Rural (<… | 0.018858 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | | Zirconium-95 | elementary | water/River | 3.6976e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Krypton-85 | elementary | air/Medium stack, <150 meters / Rural (<… | 2.4330e-05 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Barium-140 | elementary | air/Medium stack, <150 meters / Rural (<… | 7.8142e-13 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cobalt-58 | elementary | water/River | 2.8101e-06 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Antimony-125 | elementary | air/Medium stack, <150 meters / Rural (<… | 5.7682e-11 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cesium-137 | elementary | water/River | 2.4650e-07 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Iodine-133 | elementary | water/River | 1.0255e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Tellurium-123m | elementary | water/River | 3.8701e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Niobium-95 | elementary | air/Medium stack, <150 meters / Rural (<… | 2.7608e-13 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cesium-136 | elementary | water/River | 6.9268e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Iodine-131 | elementary | water/River | 2.0238e-08 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Tellurium-132 | elementary | water/River | 2.0756e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cobalt-60 | elementary | air/Medium stack, <150 meters / Rural (<… | 1.8660e-10 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Iodine-131 | elementary | air/Medium stack, <150 meters / Rural (<… | 8.3318e-09 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Cobalt-60 | elementary | water/River | 9.7369e-07 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Silver-110m | elementary | air/Medium stack, <150 meters / Rural (<… | 7.7156e-12 | kBq | lognormal, GSD² 3.05 | — | 0.0 | · | | | Water, CH | elementary | water/Unknown [CH] | 1.3465e-05 | m3 | lognormal, GSD² 2.52 | — | 0.0 | · | | ==== Data quality ==== 0 of 87 direct exchanges carry a declared pedigree, 87 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Livia Waldburger (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | none | | sampling procedure | literature | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 02.12.2020; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme_A konvertieren[EcoSpold_heat at nuclear power plant onlyv0.1.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **2.039e-07** | 1.704e-07 | 2.800e-07 | 1.3 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.527e-08** | 3.115e-08 | 1.027e-07 | 1.83 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.396e-05** | 2.839e-05 | 4.746e-05 | 1.29 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.477e-08** | 1.857e-08 | 4.345e-08 | 1.55 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.403e-05** | 2.846e-05 | 4.756e-05 | 1.29 | | EF-particulate Matter | Impact on human health | disease incidence | **1.816e-11** | 1.107e-11 | 3.537e-11 | 1.81 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.976e-04** | 1.684e-04 | 3.909e-04 | 1.51 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.074e-06** | 1.797e-06 | 4.444e-06 | 1.83 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.996e-04** | 1.710e-04 | 3.939e-04 | 1.51 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **9.979e-08** | 7.892e-08 | 1.495e-07 | 1.37 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.628e-08** | 1.050e-08 | 5.795e-08 | 2.41 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **3.758e-07** | 3.079e-07 | 5.748e-07 | 1.37 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.948e-15** | 8.860e-15 | 2.409e-14 | 1.7 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.251e-15** | 2.793e-15 | 6.345e-15 | 1.49 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.320e-14** | 1.192e-14 | 2.888e-14 | 1.59 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.806e-13** | 4.813e-13 | 1.524e-12 | 1.82 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.350e-14** | 1.105e-14 | 2.462e-14 | 1.5 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.941e-13** | 4.949e-13 | 1.540e-12 | 1.8 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.003508** | 0.001095 | 0.02355 | 4.88 | | Land use | Soil quality index | pt (soil quality index) | **1.493e-04** | 1.226e-04 | 3.054e-04 | 1.6 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.123e-10** | 8.354e-11 | 1.552e-10 | 1.38 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.319e-07** | 1.107e-07 | 2.013e-07 | 1.35 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.03414** | 0.02617 | 0.04832 | 1.37 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **7.997e-11** | 6.094e-11 | 1.759e-10 | 1.7 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **3.082e-04** | -0.005592 | 0.003176 | — | Climate change 3.403e-05 kg CO2 eq per MJ. Main contributors: U enriched 4.75%, in fuel element for LWR, at nuclear fuel f… 90 %; Nuclear power plant, pressure water reactor 1000MW 5 %; Nuclear spent fuel, in reprocessing, at plant 2 %; Nuclear spent fuel, in conditioning, at plant 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: U enriched 4.75%, in fuel element for LWR, at nuclear fuel f… 90 %; Nuclear power plant, pressure water reactor 1000MW 5 %; Nuclear spent fuel, in reprocessing, at plant 2 %; Nuclear spent fuel, in conditioning, at plant 1 %. Most sensitive exchanges (Section 6.3): U enriched 4.75%, in fuel element for LWR, at nuclear fuel fabrication plant [CH] (-15.8 / +19.2 %); Nuclear power plant, pressure water reactor 1000MW [CH] (-3.7 / +10.9 %); Nuclear spent fuel, in reprocessing, at plant [RER] (-0.4 / +0.4 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 2.039e-07 | 2.494e-07 | 0.818 | | Climate change-Biogenic | 4.527e-08 | 4.527e-08 | 1.000 | | Climate change-Fossil | 3.396e-05 | 3.396e-05 | 1.000 | | Climate change-Land use and land use change | 2.477e-08 | 2.477e-08 | 1.000 | | Climate change | 3.403e-05 | 3.403e-05 | 1.000 | | EF-particulate Matter | 1.816e-11 | 1.816e-11 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.976e-04 | 2.577e-04 | 0.767 | | Ecotoxicity, freshwater_organics | 2.074e-06 | 1.768e-06 | 1.173 | | Ecotoxicity, freshwater | 1.996e-04 | 2.594e-04 | 0.770 | | Eutrophication marine | 9.979e-08 | 9.649e-08 | 1.034 | | Eutrophication, freshwater | 1.628e-08 | 1.628e-08 | 1.000 | | Eutrophication, terrestrial | 3.758e-07 | 4.208e-07 | 0.893 | | Human toxicity, cancer_inorganics | 9.948e-15 | 7.920e-15 | 1.256 | | Human toxicity, cancer_organics | 3.251e-15 | 3.251e-15 | 1.000 | | Human toxicity, cancer | 1.320e-14 | 1.117e-14 | 1.182 | | Human toxicity, non-cancer_inorganics | 5.806e-13 | 4.334e-13 | 1.340 | | Human toxicity, non-cancer_organics | 1.350e-14 | 1.346e-14 | 1.003 | | Human toxicity, non-cancer | 5.941e-13 | 4.468e-13 | 1.330 | | Ionising radiation, human health | 0.003508 | 0.003508 | 1.000 | | Land use | 1.493e-04 | 1.236e-04 | 1.208 | | Ozone depletion | 1.123e-10 | 1.123e-10 | 1.000 | | Photochemical ozone formation - human health | 1.319e-07 | 1.319e-07 | 1.000 | | Resource use, fossils | 0.03414 | 0.03414 | 1.000 | | Resource use, minerals and metals | 7.997e-11 | 7.470e-11 | 1.071 | | Water use | 3.082e-04 | 3.403e-04 | 0.906 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 3.403e-05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.341 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | U enriched 4.75%, in fuel element for LWR, at nuclear fuel fabrication plant [CH] | 5.349e-09 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -15.8 / +19.2 | 21.4 (Ozone depletion) | | Nuclear power plant, pressure water reactor 1000MW [CH] | 6.360e-15 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -3.7 / +10.9 | 78.6 (Resource use, minerals and metals) | | Nuclear spent fuel, in reprocessing, at plant [RER] | 2.426e-09 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.4 / +0.4 | 2.5 (Ionising radiation, human health) | | Nuclear spent fuel, in conditioning, at plant [CH] | 3.648e-09 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.2 / +0.3 | 3.0 (Resource use, minerals and metals) | | Radioactive waste, in final repository for nuclear waste LLW [CH] | 7.001e-11 m3 | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.3 (Human toxicity, non-cancer_organics) | | Diesel, burned in diesel-electric generating set [GLO] | 9.121e-07 MJ | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.1 | 0.4 (Climate change-Land use and land use change) | | Water, decarbonised, at plant [RER] | 0.006606 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 20.3 (Water use) | | Hydrogen, liquid, at plant [RER] | 2.539e-08 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 6.409e-08 tkm | ×0.494 / ×2.02 | lognormal, GSD² 2.05 | -0.0 / +0.0 | 0.1 (Ecotoxicity, freshwater_organics) | | Nitrogen, liquid, at plant [RER] | 1.521e-07 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.3 (Climate change-Biogenic) | | Sodium hypochlorite, 15% in H2O, at plant [RER] | 4.265e-08 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.7 (Ecotoxicity, freshwater_inorganics) | | Transport, freight, lorry, fleet average [RER] | 1.903e-08 tkm | ×0.494 / ×2.02 | lognormal, GSD² 2.05 | -0.0 / +0.0 | 0.1 (Ecotoxicity, freshwater_organics) | | Disposal, separator sludge, 90% water, to hazardous waste incineration [CH] | 5.398e-09 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_organics) | | Flat glass, coated, at plant [RER] | 1.077e-08 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Resource use, minerals and metals) | | Disposal, used mineral oil, 10% water, to hazardous waste incineration [CH] | 4.018e-09 kg | ×0.823 / ×1.21 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 3.403e-05 kg CO2 eq per MJ (95 % interval 2.846e-05–4.756e-05). Dominant contributors: U enriched 4.75%, in fuel element for LWR, at nuclear fuel f… 90 %; Nuclear power plant, pressure water reactor 1000MW 5 %; Nuclear spent fuel, in reprocessing, at plant 2 %; Nuclear spent fuel, in conditioning, at plant 1 %. Most sensitive: U enriched 4.75%, in fuel element for LWR, at nuclear fuel fabrication plant [CH] (-15.8 / +19.2 %); Nuclear power plant, pressure water reactor 1000MW [CH] (-3.7 / +10.9 %); Nuclear spent fuel, in reprocessing, at plant [RER] (-0.4 / +0.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 6.3e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 13/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 87/87 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 3.403e-05 in [2.846e-05, 4.756e-05] | | time period declared | **PASS** | 2019-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].