====== Disposal, ventilation system, Schulhaus Heslibach — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_schulhaus_heslibach__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Schulhaus Heslibach [CH], per 1 p. EF v3.1 climate change 2585 kg CO2 eq (Monte Carlo 95 % interval 2375–2992). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 32 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 24 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 6 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Schulhaus Heslibach | | Dataset UUID / graph id | ''%%d2439a5f-6e06-4363-8025-7e674f5f622d%%'' / ''%%activity:disposal_ventilation_system_schulhaus_heslibach__ch%%'' | | Reference product, unit | Disposal, ventilation system, Schulhaus Heslibach, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation system for a school with schoolrooms and recreation room. The inventory is based on a building with a total heated gross floor area of 2849 m2 and a total nominal air flow of 13630 m3/h, total weight of the components: 3822 kg/Unit, building with a specific air flow rate of 4.8 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central and decentral air handling units. Building without ground heat exchanger.; UUID: d2439a5f-6e06-4363-8025-7e674f5f622d This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Schulhaus Heslibach (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 273.21 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 32.1 | ██████ | | | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger | technosphere | CH | 0.737 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 23.8 | █████ | | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | technosphere | CH | 0.729 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 8.4 | ██ | | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 710.01 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.9 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 465.53 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.0 | █ | | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 801.91 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.0 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 351.16 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.5 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 596.23 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.1 | █ | | | Disposal, ventilation system, Schulhaus Heslibach, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.0 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 397.65 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.8 | █ | | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 280.69 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.0 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm | technosphere | CH | 44.772 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 55.867 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.4 | · | | | Disposal, ventilation equipment, central, 600-1200 m3/h | technosphere | CH | 2 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.2 | · | | | Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 4.7814 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, thermal insulation, 30mm, 40kg/m3, stainless steel cladding | technosphere | CH | 21.393 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, spiral-seam duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 2.5308 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 2.8746 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 18 of 18 direct exchanges carry a declared pedigree, 18 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.17 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.5681** | 0.5344 | 0.9526 | 1.37 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.3912** | 0.311 | 0.7552 | 1.56 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2584** | 2374 | 2992 | 1.13 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.07102** | 0.06134 | 0.109 | 1.34 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2585** | 2375 | 2992 | 1.13 | | EF-particulate Matter | Impact on human health | disease incidence | **5.370e-05** | 3.317e-05 | 1.110e-04 | 1.85 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **6874** | 5555 | 1.103e+04 | 1.42 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **32.38** | 28.05 | 59.08 | 1.48 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **6907** | 5594 | 1.107e+04 | 1.42 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.6159** | 0.5295 | 1.151 | 1.51 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.4244** | 0.05912 | 12.86 | 16.7 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **4.603** | 3.914 | 9.05 | 1.55 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.860e-08** | 9.863e-08 | 3.696e-07 | 1.95 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.683e-08** | 4.037e-08 | 7.282e-08 | 1.36 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.454e-07** | 1.510e-07 | 4.245e-07 | 1.7 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.857e-06** | 5.736e-06 | 2.039e-05 | 1.93 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.904e-07** | 2.944e-07 | 6.113e-07 | 1.46 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.247e-06** | 6.128e-06 | 2.081e-05 | 1.88 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **64.81** | 24.72 | 386.1 | 4.14 | | Land use | Soil quality index | pt (soil quality index) | **2868** | -563.3 | 7483 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.672e-06** | 6.968e-06 | 1.160e-05 | 1.29 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **1.811** | 1.556 | 3.235 | 1.46 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3468** | 3229 | 5157 | 1.27 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **4.532e-04** | 3.868e-04 | 8.796e-04 | 1.53 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **229.6** | -2.83e+04 | 1.489e+04 | — | Climate change 2585 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 32 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 24 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 6 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 32 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 24 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 6 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 5 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-6.1 / +7.5 %); Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-4.8 / +6.0 %); Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-1.7 / +2.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.5681 | 1.217 | 0.467 | | Climate change-Biogenic | 0.3912 | 0.3912 | 1.000 | | Climate change-Fossil | 2584 | 2584 | 1.000 | | Climate change-Land use and land use change | 0.07102 | 0.07102 | 1.000 | | Climate change | 2585 | 2585 | 1.000 | | EF-particulate Matter | 5.370e-05 | 5.370e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 6874 | 7163 | 0.960 | | Ecotoxicity, freshwater_organics | 32.38 | 32.27 | 1.003 | | Ecotoxicity, freshwater | 6907 | 7194 | 0.960 | | Eutrophication marine | 0.6159 | 0.6158 | 1.000 | | Eutrophication, freshwater | 0.4244 | 0.4244 | 1.000 | | Eutrophication, terrestrial | 4.603 | 5.833 | 0.789 | | Human toxicity, cancer_inorganics | 9.860e-08 | 9.830e-08 | 1.003 | | Human toxicity, cancer_organics | 4.683e-08 | 4.683e-08 | 1.000 | | Human toxicity, cancer | 1.454e-07 | 1.451e-07 | 1.002 | | Human toxicity, non-cancer_inorganics | 5.857e-06 | 5.811e-06 | 1.008 | | Human toxicity, non-cancer_organics | 3.904e-07 | 3.904e-07 | 1.000 | | Human toxicity, non-cancer | 6.247e-06 | 6.202e-06 | 1.007 | | Ionising radiation, human health | 64.81 | 64.81 | 1.000 | | Land use | 2868 | 1654 | 1.734 | | Ozone depletion | 7.672e-06 | 7.672e-06 | 1.000 | | Photochemical ozone formation - human health | 1.811 | 1.811 | 1.000 | | Resource use, fossils | 3468 | 3468 | 1.000 | | Resource use, minerals and metals | 4.532e-04 | 3.899e-04 | 1.162 | | Water use | 229.6 | 231.8 | 0.991 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2585 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 4.663e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 273.2 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -6.1 / +7.5 | 7.5 (Climate change-Fossil) | | Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] | 0.737 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -4.8 / +6.0 | 14.6 (Water use) | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] | 0.729 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.7 / +2.1 | 4.2 (Ecotoxicity, freshwater_inorganics) | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 710 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.3 / +1.6 | 17.0 (Eutrophication, freshwater) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm [CH] | 465.5 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.1 / +1.4 | 1.8 (Ionising radiation, human health) | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 801.9 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.0 / +1.2 | 3.9 (Eutrophication, freshwater) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 351.2 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.9 / +1.1 | 1.2 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 596.2 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 2.7 (Ionising radiation, human health) | | Disposal, ventilation system, Schulhaus Heslibach, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.7 | 2.2 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 397.6 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.7 | 2.2 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 280.7 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 1.8 (Ionising radiation, human health) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.8mm [CH] | 44.77 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.2 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 1.25mm [CH] | 55.87 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.1 | 0.5 (Ionising radiation, human health) | | Disposal, ventilation equipment, central, 600-1200 m3/h [CH] | 2 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.1 / +0.1 | 0.3 (Climate change-Land use and land use change) | | Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 4.781 m | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 2585 kg CO2 eq per p (95 % interval 2375–2992). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 32 %; Disposal, ventilation unit 13000 m3/h, w. rotary heat exchan… 24 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 8 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm 6 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 5 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-6.1 / +7.5 %); Disposal, ventilation unit 13000 m3/h, w. rotary heat exchanger [CH] (-4.8 / +6.0 %); Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-1.7 / +2.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.9e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 18/18 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2585 in [2375, 2992] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].