====== 3kWp slanted-roof installation, CdTe, panel, mounted, on roof — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:3kwp_slanted_roof_installation_cdte_panel_mounted_on_roof__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 3kWp slanted-roof installation, CdTe, panel, mounted, on roof [CH], per 1 p. EF v3.1 climate change 2110 kg CO2 eq (Monte Carlo 95 % interval 1353–5760). Main contributors: Photovoltaic laminate, CdTe, mix, at regional storage 43 %; Inverter, 2.5 kW, average, at plant 30 %; Slanted-roof construction, mounted, on roof 16 %; Electric installation, photovoltaic plant, at plant 6 %; Treatment, CdTe PV module 4 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof | | Dataset UUID / graph id | ''%%e0c7a37f-365c-3471-ab33-2d88f7e8d6fc%%'' / ''%%activity:3kwp_slanted_roof_installation_cdte_panel_mounted_on_roof__ch%%'' | | Reference product, unit | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof, 1 p | | Location | CH — Installation in Switzerland. | | Time period | 2000-01/2018-12 | | Category | photovoltaic / production of components | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 3kWp and a life time of 30 years installed in Switzerland. The efficiency of CdTe PV modules is 16.8% (average of First Solar Series 4 and Series 6 modules in 2018). The share of rejected or replaced PV modules is 1% based on company information. The inverter is assumed to be replaced once during the service life of the PV system.; UUID: e0c7a37f-365c-3471-ab33-2d88f7e8d6fc This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 3kWp slanted-roof installation, CdTe, panel, mounted, on roof (CH). All results are given per unit of the reference flow. ==== System boundary ==== All components for the installation of a 3kWp photovoltaic plant, energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic laminate, CdTe, mix, at regional storage | technosphere | RER | 16.833 | m2 | lognormal, GSD² 3.08 | (3,4,3,1,1,5) | 43.0 | █████████ | | | Inverter, 2.5 kW, average, at plant | technosphere | RER | 2.4 | p | lognormal, GSD² 3.02 | — | 30.1 | ██████ | | | Slanted-roof construction, mounted, on roof | technosphere | RER | 16.667 | m2 | lognormal, GSD² 3.01 | — | 16.3 | ███ | | | Electric installation, photovoltaic plant, at plant | technosphere | CH | 1 | p | lognormal, GSD² 3.08 | (3,4,3,1,1,5) | 5.9 | █ | | | Treatment, CdTe PV module | technosphere | DE | 269.5 | kg | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 3.8 | █ | | | Transport, freight, lorry, 7.5t-16t gross weight, fleet average | technosphere | RER | 40.371 | tkm | lognormal, GSD² 2.09 | (3,4,3,1,1,5) | 0.8 | · | | | Electricity, low voltage, at grid | technosphere | CH | 0.23 | kWh | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.828 | MJ | lognormal, GSD² 1.28 | (3,4,3,1,1,5) | 0.0 | · | | ==== Data quality ==== 6 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.0 · completeness 4.0 · temporal 3.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | Estimations for lifetime of PV modules (30a) and inverters (15a) as well as for transport distances. | | sampling procedure | Publication for efficiency, mounting systems and own estimations for other components. | | production volume | Total installed capacity in 2018: approximately 2200 MWp in Switzerland. | | uncertainty adjustments | | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | Average module efficiency in 2018. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **12.79** | 8.383 | 32.9 | 2.01 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **6.882** | 3.474 | 26.42 | 2.88 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2101** | 1348 | 5730 | 2.06 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.472** | 0.9971 | 3.692 | 1.92 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2110** | 1353 | 5760 | 2.06 | | EF-particulate Matter | Impact on human health | disease incidence | **9.175e-05** | 6.391e-05 | 8.082e-04 | 3.42 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.179e+04** | 8623 | 4.22e+04 | 2.24 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **319.9** | 227.9 | 1004 | 2.12 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.211e+04** | 8874 | 4.305e+04 | 2.23 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.67** | 1.757 | 7.948 | 2.11 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **3.932** | 1.827 | 31.95 | 4.03 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **25.75** | 16.6 | 76.98 | 2.16 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.388e-06** | 1.052e-06 | 5.631e-06 | 2.32 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.571e-07** | 3.282e-07 | 1.303e-06 | 2.03 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.845e-06** | 1.504e-06 | 6.613e-06 | 2.16 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.530e-05** | 6.968e-05 | 3.826e-04 | 2.38 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.702e-06** | 2.684e-06 | 1.365e-05 | 2.25 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.000e-04** | 7.344e-05 | 3.925e-04 | 2.35 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **440.1** | 136.1 | 3585 | 5.28 | | Land use | Soil quality index | pt (soil quality index) | **1.352e+04** | 8952 | 3.992e+04 | 2.14 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **7.770e-05** | 5.002e-05 | 2.179e-04 | 2.1 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **8.522** | 5.737 | 24.28 | 2.06 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **2.807e+04** | 1.828e+04 | 8.137e+04 | 2.08 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.4829** | 0.2284 | 1.378 | 2.51 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **251.1** | -6.286e+05 | 3.387e+05 | — | Climate change 2110 kg CO2 eq per p. Main contributors: Photovoltaic laminate, CdTe, mix, at regional storage 43 %; Inverter, 2.5 kW, average, at plant 30 %; Slanted-roof construction, mounted, on roof 16 %; Electric installation, photovoltaic plant, at plant 6 %; Treatment, CdTe PV module 4 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic laminate, CdTe, mix, at regional storage 43 %; Inverter, 2.5 kW, average, at plant 30 %; Slanted-roof construction, mounted, on roof 16 %; Electric installation, photovoltaic plant, at plant 6 %; Treatment, CdTe PV module 4 %. Most sensitive exchanges (Section 6.3): Photovoltaic laminate, CdTe, mix, at regional storage [RER] (-28.7 / +86.5 %); Inverter, 2.5 kW, average, at plant [RER] (-19.9 / +58.7 %); Slanted-roof construction, mounted, on roof [RER] (-10.8 / +31.8 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 12.79 | 13.53 | 0.946 | | Climate change-Biogenic | 6.882 | 6.882 | 1.000 | | Climate change-Fossil | 2101 | 2101 | 1.000 | | Climate change-Land use and land use change | 1.472 | 1.472 | 1.000 | | Climate change | 2110 | 2110 | 1.000 | | EF-particulate Matter | 9.175e-05 | 9.175e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.179e+04 | 1.231e+04 | 0.958 | | Ecotoxicity, freshwater_organics | 319.9 | 285.8 | 1.119 | | Ecotoxicity, freshwater | 1.211e+04 | 1.247e+04 | 0.971 | | Eutrophication marine | 2.67 | 2.67 | 1.000 | | Eutrophication, freshwater | 3.932 | 3.932 | 1.000 | | Eutrophication, terrestrial | 25.75 | 26.56 | 0.969 | | Human toxicity, cancer_inorganics | 1.388e-06 | 1.380e-06 | 1.005 | | Human toxicity, cancer_organics | 4.571e-07 | 4.571e-07 | 1.000 | | Human toxicity, cancer | 1.845e-06 | 1.838e-06 | 1.004 | | Human toxicity, non-cancer_inorganics | 9.530e-05 | 9.474e-05 | 1.006 | | Human toxicity, non-cancer_organics | 4.702e-06 | 4.701e-06 | 1.000 | | Human toxicity, non-cancer | 1.000e-04 | 9.944e-05 | 1.006 | | Ionising radiation, human health | 440.1 | 440.1 | 1.000 | | Land use | 1.352e+04 | 1.131e+04 | 1.196 | | Ozone depletion | 7.770e-05 | 7.770e-05 | 1.000 | | Photochemical ozone formation - human health | 8.522 | 8.521 | 1.000 | | Resource use, fossils | 2.807e+04 | 2.807e+04 | 1.000 | | Resource use, minerals and metals | 0.4829 | 0.4817 | 1.002 | | Water use | 251.1 | 271.9 | 0.924 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2109 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 5.797e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic laminate, CdTe, mix, at regional storage [RER] | 16.83 m2 | ×0.332 / ×3.01 | lognormal, GSD² 3.08 | -28.7 / +86.5 | 97.0 (Eutrophication, terrestrial) | | Inverter, 2.5 kW, average, at plant [RER] | 2.4 p | ×0.339 / ×2.95 | lognormal, GSD² 3.02 | -19.9 / +58.7 | 160.0 (Resource use, minerals and metals) | | Slanted-roof construction, mounted, on roof [RER] | 16.67 m2 | ×0.339 / ×2.95 | lognormal, GSD² 3.01 | -10.8 / +31.8 | 73.5 (Ionising radiation, human health) | | Electric installation, photovoltaic plant, at plant [CH] | 1 p | ×0.332 / ×3.01 | lognormal, GSD² 3.08 | -4.0 / +12.0 | 104.5 (Human toxicity, non-cancer_organics) | | Treatment, CdTe PV module [DE] | 269.5 kg | ×0.782 / ×1.28 | lognormal, GSD² 1.28 | -0.8 / +1.1 | 3.5 (Climate change-Land use and land use change) | | Transport, freight, lorry, 7.5t-16t gross weight, fleet average [RER] | 40.37 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -0.4 / +0.9 | 4.7 (Climate change-Land use and land use change) | | Electricity, low voltage, at grid [CH] | 0.23 kWh | ×0.782 / ×1.28 | lognormal, GSD² 1.28 | -0.0 / +0.0 | 0.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | 3kWp slanted-roof installation, CdTe, panel, mounted, on roof [RER] | 2103 kg CO2 eq | 2110 | 1.00 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 2110 kg CO2 eq per p (95 % interval 1353–5760). Dominant contributors: Photovoltaic laminate, CdTe, mix, at regional storage 43 %; Inverter, 2.5 kW, average, at plant 30 %; Slanted-roof construction, mounted, on roof 16 %; Electric installation, photovoltaic plant, at plant 6 %; Treatment, CdTe PV module 4 %. Most sensitive: Photovoltaic laminate, CdTe, mix, at regional storage [RER] (-28.7 / +86.5 %); Inverter, 2.5 kW, average, at plant [RER] (-19.9 / +58.7 %); Slanted-roof construction, mounted, on roof [RER] (-10.8 / +31.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2110 in [1353, 5760] | | time period declared | **PASS** | 2000-01/2018-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].