====== Tap water, water balance according to MoeK 2013, at user — RU ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:tap_water_water_balance_according_to_moek_2013_at_user__ru|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Tap water, water balance according to MoeK 2013, at user [RU], per 1 kg. EF v3.1 climate change 2.796e-04 kg CO2 eq (Monte Carlo 95 % interval 2.189e-04–5.056e-04). Main contributors: Electricity, medium voltage, at grid 66 %; Water works 15 %; Water supply network 6 %; Ozone, liquid, at plant 5 %; Water storage 2 %; Charcoal, at plant 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Tap water, water balance according to MoeK 2013, at user | | Dataset UUID / graph id | ''%%e0f18ddf-f79f-3b0a-9cd6-ec050969dfaf%%'' / ''%%activity:tap_water_water_balance_according_to_moek_2013_at_user__ru%%'' | | Reference product, unit | Tap water, water balance according to MoeK 2013, at user, 1 kg | | Location | RU | | Time period | 2000-01/2017-12 | | Category | water / water supply\production | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This process is based on the dataset "tap water, at user/kg/RER U" from Ecoinvent v2.2. The electricity consumption is regionalised. The water withdrawal and water emissions to water are regionalised. The water embodied in product (1 kg/kg) is not included and has to be accounted for in the processes, which use tap water.; CAS number: 007732-18-5; Formula: H2O; UUID: e0f18ddf-f79f-3b0a-9cd6-ec050969dfaf This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kg** of Tap water, water balance according to MoeK 2013, at user (RU). All results are given per unit of the reference flow. ==== System boundary ==== Infrastructure and energy use for water treatment and transportation to the end user. No emissions from water treatment. ==== Technology ==== Example of a water works in CH. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, medium voltage, at grid | technosphere | RU | 3.9000e-04 | kWh | lognormal, GSD² 1.22 | — | 66.2 | █████████████ | | | Water works | technosphere | CH | 1.1907e-11 | p | lognormal, GSD² 3.05 | — | 14.7 | ███ | | | Water supply network | technosphere | CH | 3.1429e-10 | km | lognormal, GSD² 3.05 | — | 6.0 | █ | | | Ozone, liquid, at plant | technosphere | RER | 3.3333e-06 | kg | lognormal, GSD² 1.22 | — | 4.9 | █ | | | Water storage | technosphere | CH | 2.0568e-11 | p | lognormal, GSD² 3.05 | — | 2.2 | · | | | Charcoal, at plant | technosphere | GLO | 4.1700e-06 | kg | lognormal, GSD² 1.22 | — | 1.8 | · | | | Treatment, sewage, unpolluted, to wastewater treatment, class 3 | technosphere | CH | 1.7656e-05 | m3 | lognormal, GSD² 1.22 | — | 1.8 | · | | | Pump station | technosphere | CH | 2.0568e-11 | p | lognormal, GSD² 3.05 | — | 1.1 | · | | | Aluminium sulphate, powder, at plant | technosphere | RER | 6.3300e-06 | kg | lognormal, GSD² 1.22 | — | 0.8 | · | | | Hydrogen peroxide, 50% in H2O, at plant | technosphere | RER | 8.8000e-07 | kg | lognormal, GSD² 1.22 | — | 0.3 | · | | | Transport, freight, lorry, fleet average | technosphere | CH | 1.4813e-06 | tkm | lognormal, GSD² 2.1 | — | 0.1 | · | | | Transport, freight, rail | technosphere | RER | 8.8880e-06 | tkm | lognormal, GSD² 2.1 | — | 0.1 | · | | | Disposal, wood untreated, 20% water, to municipal incineration | technosphere | CH | 4.1700e-06 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Chlorine, liquid, production mix, at plant | technosphere | RER | 1.0000e-07 | kg | lognormal, GSD² 1.22 | — | 0.0 | · | | | Aluminium | elementary | water/River | 1.2948e-06 | kg | lognormal, GSD² 5.26 | — | 0.0 | · | | | Chloride(1-) | elementary | water/River | 5.0352e-06 | kg | lognormal, GSD² 3.23 | — | 0.0 | · | | | Water, RU | elementary | water/Unknown [RU] | 1.1100e-04 | m3 | lognormal, GSD² 1.62 | — | 0.0 | · | | | Chlorine | elementary | water/River | 1.0000e-07 | kg | lognormal, GSD² 3.23 | — | 0.0 | · | | | Water, RU | elementary | natural resource [RU] | 0.0011287 | m3 | lognormal, GSD² 1.07 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.001404 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | ==== Data quality ==== 0 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | | | sampling procedure | | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 29.03.2019; Other validation: \SRV01\ESU-Docs\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 National PV Mixes\EcoSpold[603-Tap-Water-aus-Proj603-v0.7.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **4.775e-07** | 3.396e-07 | 1.699e-06 | 2.26 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.718e-06** | 3.925e-06 | 9.144e-06 | 1.54 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.739e-04** | 2.135e-04 | 5.003e-04 | 1.54 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.295e-08** | 2.584e-08 | 9.135e-08 | 1.86 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **2.796e-04** | 2.189e-04 | 5.056e-04 | 1.53 | | EF-particulate Matter | Impact on human health | disease incidence | **1.228e-11** | 1.018e-11 | 2.421e-11 | 1.59 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.009676** | 0.004853 | 0.03528 | 2.75 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **3.137e-05** | 1.203e-05 | 1.833e-04 | 3.98 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.009707** | 0.00487 | 0.03532 | 2.75 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.447e-07** | 1.645e-07 | 8.896e-07 | 2.34 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **1.351e-07** | 7.424e-08 | 4.765e-07 | 2.62 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **1.955e-06** | 1.139e-06 | 8.939e-06 | 2.75 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.900e-14** | 5.004e-14 | 2.096e-13 | 2.04 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **7.309e-14** | 5.638e-14 | 1.332e-13 | 1.55 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.321e-13** | 1.148e-13 | 3.021e-13 | 1.65 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.077e-12** | 2.855e-12 | 1.731e-11 | 2.56 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.034e-13** | 8.005e-14 | 2.548e-13 | 1.78 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.181e-12** | 2.964e-12 | 1.743e-11 | 2.53 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1.443e-04** | 3.684e-05 | 9.289e-04 | 5.56 | | Land use | Soil quality index | pt (soil quality index) | **0.007436** | 0.004978 | 0.01554 | 1.82 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **6.402e-12** | 3.190e-12 | 2.858e-11 | 2.94 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **7.816e-07** | 5.512e-07 | 2.633e-06 | 2.22 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.004647** | 0.003278 | 0.01421 | 2.06 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.320e-10** | 1.798e-10 | 9.244e-10 | 2.43 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.01275** | -0.1726 | 0.1103 | — | Climate change 2.796e-04 kg CO2 eq per kg. Main contributors: Electricity, medium voltage, at grid 66 %; Water works 15 %; Water supply network 6 %; Ozone, liquid, at plant 5 %; Water storage 2 %; Charcoal, at plant 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, medium voltage, at grid 66 %; Water works 15 %; Water supply network 6 %; Ozone, liquid, at plant 5 %; Water storage 2 %; Charcoal, at plant 2 %. Most sensitive exchanges (Section 6.3): Water works [CH] (-9.7 / +29.1 %); Electricity, medium voltage, at grid [RU] (-11.9 / +14.5 %); Water supply network [CH] (-4.0 / +11.9 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 4.775e-07 | 9.828e-07 | 0.486 | | Climate change-Biogenic | 5.718e-06 | 5.718e-06 | 1.000 | | Climate change-Fossil | 2.739e-04 | 2.739e-04 | 1.000 | | Climate change-Land use and land use change | 3.295e-08 | 3.295e-08 | 1.000 | | Climate change | 2.796e-04 | 2.796e-04 | 1.000 | | EF-particulate Matter | 1.228e-11 | 1.228e-11 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.009676 | 0.009692 | 0.998 | | Ecotoxicity, freshwater_organics | 3.137e-05 | 3.109e-05 | 1.009 | | Ecotoxicity, freshwater | 0.009707 | 0.009723 | 0.998 | | Eutrophication marine | 2.447e-07 | 2.447e-07 | 1.000 | | Eutrophication, freshwater | 1.351e-07 | 1.351e-07 | 1.000 | | Eutrophication, terrestrial | 1.955e-06 | 2.344e-06 | 0.834 | | Human toxicity, cancer_inorganics | 5.900e-14 | 5.459e-14 | 1.081 | | Human toxicity, cancer_organics | 7.309e-14 | 7.309e-14 | 1.000 | | Human toxicity, cancer | 1.321e-13 | 1.277e-13 | 1.035 | | Human toxicity, non-cancer_inorganics | 4.077e-12 | 3.990e-12 | 1.022 | | Human toxicity, non-cancer_organics | 1.034e-13 | 1.034e-13 | 1.000 | | Human toxicity, non-cancer | 4.181e-12 | 4.094e-12 | 1.021 | | Ionising radiation, human health | 1.443e-04 | 1.443e-04 | 1.000 | | Land use | 0.007436 | 0.004284 | 1.736 | | Ozone depletion | 6.402e-12 | 6.402e-12 | 1.000 | | Photochemical ozone formation - human health | 7.816e-07 | 7.816e-07 | 1.000 | | Resource use, fossils | 0.004647 | 0.004649 | 1.000 | | Resource use, minerals and metals | 3.320e-10 | 3.102e-10 | 1.070 | | Water use | 0.01275 | 0.01275 | 1.000 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 2.796e-04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 0.4943 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Water works [CH] | 1.191e-11 p | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -9.7 / +29.1 | 81.1 (Land use) | | Electricity, medium voltage, at grid [RU] | 3.900e-04 kWh | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -11.9 / +14.5 | 18.6 (Ecotoxicity, freshwater_organics) | | Water supply network [CH] | 3.143e-10 km | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -4.0 / +11.9 | 111.5 (Human toxicity, non-cancer_inorganics) | | Water storage [CH] | 2.057e-11 p | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -1.4 / +4.3 | 33.1 (Land use) | | Pump station [CH] | 2.057e-11 p | ×0.335 / ×2.99 | lognormal, GSD² 3.05 | -0.7 / +2.2 | 16.1 (Resource use, minerals and metals) | | Ozone, liquid, at plant [RER] | 3.333e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.9 / +1.1 | 5.0 (Climate change-Land use and land use change) | | Charcoal, at plant [GLO] | 4.170e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.3 / +0.4 | 17.4 (Climate change-Biogenic) | | Treatment, sewage, unpolluted, to wastewater treatment, class 3 [CH] | 1.766e-05 m3 | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.3 / +0.4 | 1.7 (Resource use, minerals and metals) | | Aluminium sulphate, powder, at plant [RER] | 6.330e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.2 / +0.2 | 1.6 (Human toxicity, cancer_inorganics) | | Transport, freight, lorry, fleet average [CH] | 1.481e-06 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.1 | 0.2 (Resource use, minerals and metals) | | Hydrogen peroxide, 50% in H2O, at plant [RER] | 8.800e-07 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.1 / +0.1 | 0.2 (Resource use, minerals and metals) | | Transport, freight, rail [RER] | 8.888e-06 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.0 / +0.1 | 0.6 (Climate change-Land use and land use change) | | Disposal, wood untreated, 20% water, to municipal incineration [CH] | 4.170e-06 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.0 (Human toxicity, non-cancer_inorganics) | | Chlorine, liquid, production mix, at plant [RER] | 1.000e-07 kg | ×0.82 / ×1.22 | lognormal, GSD² 1.22 | -0.0 / +0.0 | 0.6 (Ozone depletion) | | Aluminium [water/River] | 1.295e-06 kg | ×0.197 / ×5.09 | lognormal, GSD² 5.26 | -0.0 / +0.0 | 238.0 (Ecotoxicity, freshwater_inorganics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== ^ Source ^ Scope ^ Value ^ This dataset ^ Ratio ^ Note ^ | bafu | Tap water, water balance according to MoeK 2013, at user [SE] | 1.104e-04 kg CO2 eq | 2.796e-04 | 2.53 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [NO] | 1.155e-04 kg CO2 eq | 2.796e-04 | 2.42 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [FR] | 1.231e-04 kg CO2 eq | 2.796e-04 | 2.27 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [CH] | 1.294e-04 kg CO2 eq | 2.796e-04 | 2.16 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [BR] | 1.330e-04 kg CO2 eq | 2.796e-04 | 2.10 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [MY] | 3.927e-04 kg CO2 eq | 2.796e-04 | 0.71 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [BA] | 4.279e-04 kg CO2 eq | 2.796e-04 | 0.65 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [RS] | 4.466e-04 kg CO2 eq | 2.796e-04 | 0.63 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [IN] | 4.719e-04 kg CO2 eq | 2.796e-04 | 0.59 | same dataset name, other location | | bafu | Tap water, water balance according to MoeK 2013, at user [ZA] | 4.961e-04 kg CO2 eq | 2.796e-04 | 0.56 | same dataset name, other location | ==== Conclusions and limitations ==== GWP100 2.796e-04 kg CO2 eq per kg (95 % interval 2.189e-04–5.056e-04). Dominant contributors: Electricity, medium voltage, at grid 66 %; Water works 15 %; Water supply network 6 %; Ozone, liquid, at plant 5 %; Water storage 2 %; Charcoal, at plant 2 %. Most sensitive: Water works [CH] (-9.7 / +29.1 %); Electricity, medium voltage, at grid [RU] (-11.9 / +14.5 %); Water supply network [CH] (-4.0 / +11.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kg | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 6.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 2.796e-04 in [2.189e-04, 5.056e-04] | | time period declared | **PASS** | 2000-01/2017-12 | | geography is a known location code | **PASS** | RU | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Stolz P., Frischknecht R. (2017) Life Cycle Water Use of Photovoltaic Electricity. Volume: 174. treeze Ltd.. Uster. Type: Separate publication Source: Report First author: Stolz P. Other authors: Frischknecht R. Year: 2017 Place of publication: Uster Publisher: treeze Ltd. Volume No: 174 — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].