====== Heat, at system cogen 160kWe Jakobsberg, allocation heat — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_at_system_cogen_160kwe_jakobsberg_allocation_heat__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, at system cogen 160kWe Jakobsberg, allocation heat [CH], per 1 MJ. EF v3.1 climate change 0.1153 kg CO2 eq (Monte Carlo 95 % interval 0.09863–0.1485). Main contributors: Heat, at module cogen 160kWe Jakobsberg, allocation heat 65 %; Heat, light fuel oil, at boiler 100kW, non-modulating 35 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, at system cogen 160kWe Jakobsberg, allocation heat | | Dataset UUID / graph id | ''%%e1e448df-4c6c-3eda-8de2-885a9f13bdcd%%'' / ''%%activity:heat_at_system_cogen_160kwe_jakobsberg_allocation_heat__ch%%'' | | Reference product, unit | Heat, at system cogen 160kWe Jakobsberg, allocation heat, 1 MJ | | Location | CH — Efficiencies refer to a specific plant in Switzerland. | | Time period | 2000-01/2000-12 | | Category | heat / natural gas\cogeneration | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Heat at system i.e. distribution is not included.; UUID: e1e448df-4c6c-3eda-8de2-885a9f13bdcd This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, at system cogen 160kWe Jakobsberg, allocation heat (CH). All results are given per unit of the reference flow. ==== System boundary ==== The module includes heat from module cogen (i.e. the cogeneration unit and a heat pump) and from two oil boilers. ==== Technology ==== Specific cogeneration unit installed in Switzerland. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Heat, at module cogen 160kWe Jakobsberg, allocation heat | technosphere | CH | 0.6 | MJ | lognormal, GSD² 1.05 | — | 64.8 | █████████████ | | | Heat, light fuel oil, at boiler 100kW, non-modulating | technosphere | CH | 0.4 | MJ | lognormal, GSD² 1.05 | — | 35.2 | ███████ | | ==== Data quality ==== 0 of 2 direct exchanges carry a declared pedigree, 2 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | none | | sampling procedure | Operator information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: prepared; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **7.816e-05** | 6.179e-05 | 1.300e-04 | 1.45 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.068e-05** | 2.605e-05 | 1.949e-04 | 2.74 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1152** | 0.09859 | 0.1483 | 1.23 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **8.834e-06** | 6.602e-06 | 1.735e-05 | 1.64 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.1153** | 0.09863 | 0.1485 | 1.23 | | EF-particulate Matter | Impact on human health | disease incidence | **6.619e-10** | 5.509e-10 | 1.146e-09 | 1.47 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.3059** | 0.1798 | 0.8634 | 2.22 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008441** | 0.005627 | 0.01785 | 1.81 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.3144** | 0.1874 | 0.8758 | 2.19 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **3.352e-05** | 2.641e-05 | 5.542e-05 | 1.46 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **3.008e-06** | 1.970e-06 | 1.567e-05 | 2.88 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.839e-04** | 2.247e-04 | 4.804e-04 | 1.46 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.851e-12** | 3.553e-12 | 1.096e-11 | 1.79 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.771e-12** | 2.064e-12 | 7.782e-12 | 1.94 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.622e-12** | 6.096e-12 | 1.717e-11 | 1.7 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.771e-10** | 2.258e-10 | 8.100e-10 | 1.89 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.780e-11** | 2.841e-11 | 6.194e-11 | 1.48 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **3.149e-10** | 2.604e-10 | 8.532e-10 | 1.82 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.004141** | 0.001375 | 0.03184 | 5.12 | | Land use | Soil quality index | pt (soil quality index) | **0.07743** | 0.06326 | 0.1796 | 1.71 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.417e-09** | 2.328e-09 | 5.896e-09 | 1.58 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.167e-04** | 1.527e-04 | 3.900e-04 | 1.61 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.704** | 1.183 | 2.813 | 1.56 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **3.207e-08** | 2.728e-08 | 7.247e-08 | 1.68 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.001328** | -3.197 | 1.863 | — | Climate change 0.1153 kg CO2 eq per MJ. Main contributors: Heat, at module cogen 160kWe Jakobsberg, allocation heat 65 %; Heat, light fuel oil, at boiler 100kW, non-modulating 35 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Heat, at module cogen 160kWe Jakobsberg, allocation heat 65 %; Heat, light fuel oil, at boiler 100kW, non-modulating 35 %. Most sensitive exchanges (Section 6.3): Heat, at module cogen 160kWe Jakobsberg, allocation heat [CH] (-3.0 / +3.2 %); Heat, light fuel oil, at boiler 100kW, non-modulating [CH] (-1.6 / +1.7 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 7.816e-05 | 1.211e-04 | 0.645 | | Climate change-Biogenic | 5.068e-05 | 5.068e-05 | 1.000 | | Climate change-Fossil | 0.1152 | 0.1152 | 1.000 | | Climate change-Land use and land use change | 8.834e-06 | 8.834e-06 | 1.000 | | Climate change | 0.1153 | 0.1153 | 1.000 | | EF-particulate Matter | 6.619e-10 | 6.619e-10 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.3059 | 0.3063 | 0.999 | | Ecotoxicity, freshwater_organics | 0.008441 | 0.008393 | 1.006 | | Ecotoxicity, freshwater | 0.3144 | 0.3145 | 1.000 | | Eutrophication marine | 3.352e-05 | 3.351e-05 | 1.000 | | Eutrophication, freshwater | 3.008e-06 | 3.008e-06 | 1.000 | | Eutrophication, terrestrial | 2.839e-04 | 3.379e-04 | 0.840 | | Human toxicity, cancer_inorganics | 3.851e-12 | 3.798e-12 | 1.014 | | Human toxicity, cancer_organics | 2.771e-12 | 2.771e-12 | 1.000 | | Human toxicity, cancer | 6.622e-12 | 6.569e-12 | 1.008 | | Human toxicity, non-cancer_inorganics | 2.771e-10 | 2.752e-10 | 1.007 | | Human toxicity, non-cancer_organics | 3.780e-11 | 3.779e-11 | 1.000 | | Human toxicity, non-cancer | 3.149e-10 | 3.130e-10 | 1.006 | | Ionising radiation, human health | 0.004141 | 0.004141 | 1.000 | | Land use | 0.07743 | 0.09256 | 0.837 | | Ozone depletion | 3.417e-09 | 3.417e-09 | 1.000 | | Photochemical ozone formation - human health | 2.167e-04 | 2.167e-04 | 1.000 | | Resource use, fossils | 1.704 | 1.704 | 1.000 | | Resource use, minerals and metals | 3.207e-08 | 2.689e-08 | 1.193 | | Water use | 0.001328 | 0.001292 | 1.028 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.1153 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 144.1 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Heat, at module cogen 160kWe Jakobsberg, allocation heat [CH] | 0.6 MJ | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -3.0 / +3.2 | 3.9 (Climate change-Biogenic) | | Heat, light fuel oil, at boiler 100kW, non-modulating [CH] | 0.4 MJ | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -1.6 / +1.7 | 2.8 (EF-particulate Matter) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.1153 kg CO2 eq per MJ (95 % interval 0.09863–0.1485). Dominant contributors: Heat, at module cogen 160kWe Jakobsberg, allocation heat 65 %; Heat, light fuel oil, at boiler 100kW, non-modulating 35 %. Most sensitive: Heat, at module cogen 160kWe Jakobsberg, allocation heat [CH] (-3.0 / +3.2 %); Heat, light fuel oil, at boiler 100kW, non-modulating [CH] (-1.6 / +1.7 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.6e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 2/2 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.1153 in [0.09863, 0.1485] | | time period declared | **PASS** | 2000-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].