====== Electricity, high voltage, production from CHP natural gas, at grid — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:electricity_high_voltage_production_from_chp_natural_gas_at_grid__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, high voltage, production from CHP natural gas, at grid [CH], per 1 kWh. EF v3.1 climate change 0.642 kg CO2 eq (Monte Carlo 95 % interval 0.4686–0.9399). Main contributors: Electricity, at cogen 300kWth, natural gas, allocation exerg… 100 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Electricity, high voltage, production from CHP natural gas, at grid | | Dataset UUID / graph id | ''%%e7a1f436-1b51-38dd-b1db-f10d64df0983%%'' / ''%%activity:electricity_high_voltage_production_from_chp_natural_gas_at_grid__ch%%'' | | Reference product, unit | Electricity, high voltage, production from CHP natural gas, at grid, 1 kWh | | Location | CH — Data apply to public and self producers. Geographical classification according to IEA. Ozone- and NO2-emission factors are based on published measurements made in various countries. Assumptions for transmission network, losses and emissions are based on Swiss data. | | Time period | 2004-01/2004-12 | | Category | energy supply, kbob recommendation / electricity, delivered via network | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== This dataset describes the transmission of high voltage electricity.; UUID: e7a1f436-1b51-38dd-b1db-f10d64df0983 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 kWh** of Electricity, high voltage, production from CHP natural gas, at grid (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the electricity production in 0, the transmission network and direct emissions to air (ozone and N2O). Electricity losses are accounted for. ==== Technology ==== Average technology used to transmit and distribute electricity. Includes underground and overhead lines. Electricity production according to related datasets ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electricity, at cogen 300kWth, natural gas, allocation exergy | technosphere | CH | 1.033 | kWh | lognormal, GSD² 1.24 | (3,1,1,1,3,1) | 99.6 | ████████████████████ | | | Transmission network, electricity, high voltage | technosphere | CH | 6.8199e-09 | km | lognormal, GSD² 3.16 | (3,1,4,5,3,5) | 0.2 | · | | | Nitrous Oxide | elementary | air/Unknown | 5.0000e-06 | kg | lognormal, GSD² 1.5 | — | 0.2 | · | | | Waste Heat | elementary | air/Unknown | 0.11293 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | soil/Unknown | 0.0059435 | MJ | lognormal, GSD² 1.32 | (4,1,3,1,1,5) | 0.0 | · | | | Ozone | elementary | air/Unknown | 4.5000e-06 | kg | lognormal, GSD² 1.5 | — | 0.0 | · | | ==== Data quality ==== 4 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.5 · completeness 1.0 · temporal 2.75 · geographical 2.0 · technological 2.0 · sample size 4.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Matthias Tuchschmid; data entry: Niels Jungbluth (ESU); validation (proof reading): Niels Jungbluth (ESU) | | extrapolations | | | sampling procedure | statistics | | production volume | total electricity in Switzerland: 60 TWh | | uncertainty adjustments | none | | validation details | Proof reading validation: automatic validation in Excel; Other validation: G:\Projekte laufend\388 Aktualisierung PEF Energie\EcoSpold[388_60_electricity_from_grid-v0.3.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **3.943e-04** | 2.635e-04 | 8.025e-04 | 1.75 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3.429e-04** | 1.418e-04 | 0.001536 | 3.33 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.6416** | 0.4683 | 0.9377 | 1.42 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5.122e-05** | 3.131e-05 | 1.250e-04 | 1.98 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.642** | 0.4686 | 0.9399 | 1.43 | | EF-particulate Matter | Impact on human health | disease incidence | **2.809e-09** | 2.066e-09 | 6.122e-09 | 1.73 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.977** | 0.9866 | 5.734 | 2.48 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.04703** | 0.02532 | 0.1214 | 2.23 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.024** | 1.015 | 5.847 | 2.46 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.875e-04** | 1.897e-04 | 5.165e-04 | 1.68 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.136e-05** | 1.236e-05 | 1.261e-04 | 3.23 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.002367** | 0.001569 | 0.004275 | 1.69 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.637e-11** | 1.524e-11 | 5.617e-11 | 1.95 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.098e-11** | 2.876e-11 | 9.193e-11 | 1.8 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.735e-11** | 4.657e-11 | 1.437e-10 | 1.75 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.262e-09** | 1.080e-09 | 3.951e-09 | 1.96 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.777e-10** | 1.192e-10 | 3.413e-10 | 1.7 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.439e-09** | 1.206e-09 | 4.259e-09 | 1.91 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.02318** | 0.0062 | 0.2064 | 5.97 | | Land use | Soil quality index | pt (soil quality index) | **0.4197** | 0.2742 | 1.239 | 2.15 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.872e-08** | 9.959e-09 | 4.099e-08 | 2.08 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **0.00125** | 8.242e-04 | 0.002408 | 1.75 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **10.02** | 5.242 | 20.58 | 1.99 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **2.513e-07** | 1.883e-07 | 6.420e-07 | 1.9 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.006805** | -22.97 | 12.75 | — | Climate change 0.642 kg CO2 eq per kWh. Main contributors: Electricity, at cogen 300kWth, natural gas, allocation exerg… 100 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electricity, at cogen 300kWth, natural gas, allocation exerg… 100 %. Most sensitive exchanges (Section 6.3): Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] (-18.6 / +22.9 %); Transmission network, electricity, high voltage [CH] (-0.1 / +0.4 %); Nitrous Oxide [air/Unknown] (-0.1 / +0.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh: ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 3.943e-04 | 6.371e-04 | 0.619 | | Climate change-Biogenic | 3.429e-04 | 3.429e-04 | 1.000 | | Climate change-Fossil | 0.6416 | 0.6416 | 1.000 | | Climate change-Land use and land use change | 5.122e-05 | 5.122e-05 | 1.000 | | Climate change | 0.642 | 0.642 | 1.000 | | EF-particulate Matter | 2.809e-09 | 2.809e-09 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.977 | 1.979 | 0.999 | | Ecotoxicity, freshwater_organics | 0.04703 | 0.04676 | 1.006 | | Ecotoxicity, freshwater | 2.024 | 2.025 | 0.999 | | Eutrophication marine | 2.875e-04 | 2.874e-04 | 1.000 | | Eutrophication, freshwater | 2.136e-05 | 2.136e-05 | 1.000 | | Eutrophication, terrestrial | 0.002367 | 0.002966 | 0.798 | | Human toxicity, cancer_inorganics | 1.637e-11 | 1.599e-11 | 1.023 | | Human toxicity, cancer_organics | 4.098e-11 | 4.098e-11 | 1.000 | | Human toxicity, cancer | 5.735e-11 | 5.697e-11 | 1.007 | | Human toxicity, non-cancer_inorganics | 1.262e-09 | 1.249e-09 | 1.010 | | Human toxicity, non-cancer_organics | 1.777e-10 | 1.776e-10 | 1.000 | | Human toxicity, non-cancer | 1.439e-09 | 1.427e-09 | 1.009 | | Ionising radiation, human health | 0.02318 | 0.02318 | 1.000 | | Land use | 0.4197 | 0.4995 | 0.840 | | Ozone depletion | 1.872e-08 | 1.872e-08 | 1.000 | | Photochemical ozone formation - human health | 0.00125 | 0.00125 | 1.000 | | Resource use, fossils | 10.02 | 10.02 | 1.000 | | Resource use, minerals and metals | 2.513e-07 | 2.094e-07 | 1.200 | | Water use | 0.006805 | 0.00679 | 1.002 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.6419 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 809.5 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] | 1.033 kWh | ×0.813 / ×1.23 | lognormal, GSD² 1.24 | -18.6 / +22.9 | 23.0 (Ozone depletion) | | Transmission network, electricity, high voltage [CH] | 6.820e-09 km | ×0.324 / ×3.09 | lognormal, GSD² 3.16 | -0.1 / +0.4 | 30.0 (Resource use, minerals and metals) | | Nitrous Oxide [air/Unknown] | 5.000e-06 kg | ×0.672 / ×1.49 | lognormal, GSD² 1.5 | -0.1 / +0.1 | 0.1 (Climate change-Fossil) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.642 kg CO2 eq per kWh (95 % interval 0.4686–0.9399). Dominant contributors: Electricity, at cogen 300kWth, natural gas, allocation exerg… 100 %. Most sensitive: Electricity, at cogen 300kWth, natural gas, allocation exergy [CH] (-18.6 / +22.9 %); Transmission network, electricity, high voltage [CH] (-0.1 / +0.4 %); Nitrous Oxide [air/Unknown] (-0.1 / +0.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 kWh | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 1.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.642 in [0.4686, 0.9399] | | time period declared | **PASS** | 2004-01/2004-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht, R., Tuchschmid, M., Faist Emmenegger, M.,Bauer, C., Dones, R. (2007) Strommix und Stromnetz. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Frischknecht, R. Other authors: Tuchschmid, M., Faist Emmenegger, M.,Bauer, C.,… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].