====== 1.3 MWp slanted-roof installation, multi-Si, panel, mounted, on roof — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:1_3_mwp_slanted_roof_installation_multi_si_panel_mounted_on_roof__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 1.3 MWp slanted-roof installation, multi-Si, panel, mounted, on roof [CH], per 1 p. EF v3.1 climate change 9.958e+05 kg CO2 eq (Monte Carlo 95 % interval 4.219e+05–5.490e+06). Main contributors: Photovoltaic panel, multi-Si, at regional storage 78 %; Slanted-roof construction, mounted, on roof, Stade de Suisse 10 %; Inverter, 500kW, at plant 5 %; Electric installation, 1.3 MWp photovoltaic plant, at plant 3 %; Treatment, c-Si PV module 3 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 1.3 MWp slanted-roof installation, multi-Si, panel, mounted, on roof | | Dataset UUID / graph id | ''%%ec675697-6d86-3ed6-bbb6-430db22a50ee%%'' / ''%%activity:1_3_mwp_slanted_roof_installation_multi_si_panel_mounted_on_roof__ch%%'' | | Reference product, unit | 1.3 MWp slanted-roof installation, multi-Si, panel, mounted, on roof, 1 p | | Location | CH — Installation in CH | | Time period | 2005-01/2018-12 | | Category | electricity by fuel / photovoltaic\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 1300kWp and a life time of 30 years installed in Switzerland. The efficiency of multi-Si PV modules is 16.8% (Fraunhofer ISE Photovoltaics Report 2019). The share of rejected or replaced PV modules is estimated at 3%. The inverter is assumed to be replaced once during the service life of the PV system.; Synonyms: monocrystalline, single crystalline, silicon; UUID: ec675697-6d86-3ed6-bbb6-430db22a50ee This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 1.3 MWp slanted-roof installation, multi-Si, panel, mounted, on roof (CH). All results are given per unit of the reference flow. ==== System boundary ==== All components (modules, mounting system, electric installation, inverter) for the installation of a 1300 kWp photovoltaic plant, energy use for the mounting, transport of materials to the place of installation. Disposal of components after end of life. ==== Technology ==== Current technology for mounting of panels or laminates, electric installations and other components. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic panel, multi-Si, at regional storage | technosphere | RER | 7438.9 | m2 | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 78.5 | ████████████████ | | | Slanted-roof construction, mounted, on roof, Stade de Suisse | technosphere | CH | 7222.2 | m2 | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 10.0 | ██ | | | Inverter, 500kW, at plant | technosphere | RER | 4.4132 | p | lognormal, GSD² 4.47 | (2,4,1,1,1,5) | 5.4 | █ | | | Electric installation, 1.3 MWp photovoltaic plant, at plant | technosphere | CH | 1 | p | lognormal, GSD² 4.47 | (3,4,1,1,1,5) | 3.1 | █ | | | Treatment, c-Si PV module | technosphere | RER | 98155 | kg | lognormal, GSD² 2.77 | (3,4,1,1,1,5) | 2.7 | █ | | | Transport, freight, lorry, fleet average | technosphere | RER | 13765 | tkm | lognormal, GSD² 2.99 | — | 0.3 | · | | | Electricity, low voltage, at grid | technosphere | CH | 103.19 | kWh | lognormal, GSD² 2.77 | (3,4,3,1,1,5) | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 371.5 | MJ | lognormal, GSD² 2.06 | — | 0.0 | · | | ==== Data quality ==== 6 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.83 · completeness 4.0 · temporal 1.33 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) | | extrapolations | none | | sampling procedure | Questionnaire filled in by the engineer of the plant (Hostettler). | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **4540** | 2148 | 2.167e+04 | 3.27 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4721** | 1407 | 3.481e+04 | 5.26 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.903e+05** | 4.199e+05 | 5.450e+06 | 3.83 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **700.6** | 344.4 | 3091 | 3.11 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **9.958e+05** | 4.219e+05 | 5.490e+06 | 3.84 | | EF-particulate Matter | Impact on human health | disease incidence | **0.03618** | 0.01754 | 0.3504 | 4.62 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.827e+06** | 2.488e+06 | 3.811e+07 | 4.24 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.096e+05** | 5.597e+04 | 6.768e+05 | 3.61 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **5.937e+06** | 2.556e+06 | 3.866e+07 | 4.22 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1187** | 494.1 | 6407 | 3.87 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **604.9** | 330.2 | 5487 | 4.34 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **9050** | 4104 | 4.872e+04 | 3.66 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.902e-04** | 2.607e-04 | 0.002732 | 3.4 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.597e-04** | 1.063e-04 | 0.001592 | 4.13 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.499e-04** | 3.786e-04 | 0.004242 | 3.44 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.02336** | 0.01471 | 0.1639 | 3.29 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001405** | 6.847e-04 | 0.005843 | 2.99 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.02477** | 0.01569 | 0.1725 | 3.24 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **2.589e+05** | 6.525e+04 | 3.041e+06 | 7.28 | | Land use | Soil quality index | pt (soil quality index) | **7.209e+06** | 2.864e+06 | 4.600e+07 | 4.32 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.02989** | 0.01197 | 0.1877 | 4.25 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2993** | 1448 | 1.601e+04 | 3.53 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.329e+07** | 5.914e+06 | 7.865e+07 | 3.83 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **40.56** | 13.83 | 217 | 4.15 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **3.588e+05** | -5.080e+08 | 2.317e+08 | — | Climate change 9.958e+05 kg CO2 eq per p. Main contributors: Photovoltaic panel, multi-Si, at regional storage 78 %; Slanted-roof construction, mounted, on roof, Stade de Suisse 10 %; Inverter, 500kW, at plant 5 %; Electric installation, 1.3 MWp photovoltaic plant, at plant 3 %; Treatment, c-Si PV module 3 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic panel, multi-Si, at regional storage 78 %; Slanted-roof construction, mounted, on roof, Stade de Suisse 10 %; Inverter, 500kW, at plant 5 %; Electric installation, 1.3 MWp photovoltaic plant, at plant 3 %; Treatment, c-Si PV module 3 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel, multi-Si, at regional storage [RER] (-60.4 / +261.6 %); Slanted-roof construction, mounted, on roof, Stade de Suisse [CH] (-7.7 / +33.5 %); Inverter, 500kW, at plant [RER] (-4.2 / +18.1 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 4540 | 4702 | 0.966 | | Climate change-Biogenic | 4721 | 4721 | 1.000 | | Climate change-Fossil | 9.903e+05 | 9.903e+05 | 1.000 | | Climate change-Land use and land use change | 700.6 | 700.6 | 1.000 | | Climate change | 9.958e+05 | 9.958e+05 | 1.000 | | EF-particulate Matter | 0.03618 | 0.03618 | 1.000 | | Ecotoxicity, freshwater_inorganics | 5.827e+06 | 5.977e+06 | 0.975 | | Ecotoxicity, freshwater_organics | 1.096e+05 | 9.059e+04 | 1.210 | | Ecotoxicity, freshwater | 5.937e+06 | 6.064e+06 | 0.979 | | Eutrophication marine | 1187 | 1187 | 1.000 | | Eutrophication, freshwater | 604.9 | 604.9 | 1.000 | | Eutrophication, terrestrial | 9050 | 9360 | 0.967 | | Human toxicity, cancer_inorganics | 3.902e-04 | 3.881e-04 | 1.005 | | Human toxicity, cancer_organics | 2.597e-04 | 2.597e-04 | 1.000 | | Human toxicity, cancer | 6.499e-04 | 6.478e-04 | 1.003 | | Human toxicity, non-cancer_inorganics | 0.02336 | 0.02327 | 1.004 | | Human toxicity, non-cancer_organics | 0.001405 | 0.001404 | 1.001 | | Human toxicity, non-cancer | 0.02477 | 0.02467 | 1.004 | | Ionising radiation, human health | 2.589e+05 | 2.589e+05 | 1.000 | | Land use | 7.209e+06 | 5.825e+06 | 1.238 | | Ozone depletion | 0.02989 | 0.02989 | 1.000 | | Photochemical ozone formation - human health | 2993 | 2993 | 1.000 | | Resource use, fossils | 1.329e+07 | 1.329e+07 | 1.000 | | Resource use, minerals and metals | 40.56 | 40 | 1.014 | | Water use | 3.588e+05 | 3.600e+05 | 0.997 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 9.944e+05 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 2.072e+09 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic panel, multi-Si, at regional storage [RER] | 7439 m2 | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -60.4 / +261.6 | 315.4 (Water use) | | Slanted-roof construction, mounted, on roof, Stade de Suisse [CH] | 7222 m2 | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -7.7 / +33.5 | 69.7 (Ionising radiation, human health) | | Inverter, 500kW, at plant [RER] | 4.413 p | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -4.2 / +18.1 | 70.3 (Human toxicity, non-cancer_organics) | | Electric installation, 1.3 MWp photovoltaic plant, at plant [CH] | 1 p | ×0.231 / ×4.33 | lognormal, GSD² 4.47 | -2.4 / +10.3 | 152.4 (Human toxicity, non-cancer_organics) | | Treatment, c-Si PV module [RER] | 9.816e+04 kg | ×0.369 / ×2.71 | lognormal, GSD² 2.77 | -1.7 / +4.6 | 7.8 (Climate change-Land use and land use change) | | Transport, freight, lorry, fleet average [RER] | 1.376e+04 tkm | ×0.342 / ×2.92 | lognormal, GSD² 2.99 | -0.2 / +0.5 | 2.7 (Climate change-Land use and land use change) | | Electricity, low voltage, at grid [CH] | 103.2 kWh | ×0.369 / ×2.71 | lognormal, GSD² 2.77 | -0.0 / +0.0 | 0.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 9.958e+05 kg CO2 eq per p (95 % interval 4.219e+05–5.490e+06). Dominant contributors: Photovoltaic panel, multi-Si, at regional storage 78 %; Slanted-roof construction, mounted, on roof, Stade de Suisse 10 %; Inverter, 500kW, at plant 5 %; Electric installation, 1.3 MWp photovoltaic plant, at plant 3 %; Treatment, c-Si PV module 3 %. Most sensitive: Photovoltaic panel, multi-Si, at regional storage [RER] (-60.4 / +261.6 %); Slanted-roof construction, mounted, on roof, Stade de Suisse [CH] (-7.7 / +33.5 %); Inverter, 500kW, at plant [RER] (-4.2 / +18.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 4.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 9.958e+05 in [4.219e+05, 5.490e+06] | | time period declared | **PASS** | 2005-01/2018-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — //published source; matched in Crossref (author, year ±1, title overlap)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].