====== Cogen unit 160kWe, common components for heat+electricity — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:cogen_unit_160kwe_common_components_for_heat_plus_electricity__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 160kWe, common components for heat+electricity [RER], per 1 p. EF v3.1 climate change 7.503e+04 kg CO2 eq (Monte Carlo 95 % interval 6.703e+04–9.995e+04). Main contributors: Maintenance, cogen unit 160kWe 37 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 10 %; Gas motor 206kW 7 %; Catalytic converter, three-way, 19.1 litre 7 %; Assembly, module cogen unit 160kWe 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Cogen unit 160kWe, common components for heat+electricity | | Dataset UUID / graph id | ''%%edcd9e24-f73c-3e18-b9f7-465ef785d2e2%%'' / ''%%activity:cogen_unit_160kwe_common_components_for_heat_plus_electricity__rer%%'' | | Reference product, unit | Cogen unit 160kWe, common components for heat+electricity, 1 p | | Location | RER — Data refers to a plant in Switzerland, assumed valid for Europe (RER) | | Time period | 1990-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module summarises infrastructure components of a cogeneration unit. ; UUID: edcd9e24-f73c-3e18-b9f7-465ef785d2e2 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Cogen unit 160kWe, common components for heat+electricity (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes all shared components for heat and electricity production. Includes also three-way catalytic converter. ==== Technology ==== Infrastructure of a specific cogeneration unit installed in Switzerland. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Maintenance, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 37.3 | ███████ | | | Control cabinet cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 20.7 | ████ | | | Planning, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 10.5 | ██ | | | Gas motor 206kW | technosphere | RER | 1.25 | p | lognormal, GSD² 1.6 | — | 7.2 | █ | | | Catalytic converter, three-way, 19.1 litre | technosphere | RER | 5 | p | lognormal, GSD² 1.8 | — | 6.7 | █ | | | Assembly, module cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 5.4 | █ | | | Supply air input/spent air output cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 4.6 | █ | | | Sound insulation cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 4.3 | █ | | | Construction work, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 3.3 | █ | | | Operation start, cogen unit 160kWe | technosphere | RER | 1 | p | lognormal, GSD² 1.3 | — | 0.1 | · | | ==== Data quality ==== 0 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | see Geography/Text | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **207** | 164.9 | 364.9 | 1.51 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **261.7** | 155.6 | 660.7 | 2.07 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.475e+04** | 6.661e+04 | 9.97e+04 | 1.24 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **18.51** | 16.58 | 30.1 | 1.35 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **7.503e+04** | 6.703e+04 | 9.995e+04 | 1.24 | | EF-particulate Matter | Impact on human health | disease incidence | **0.002554** | 0.002072 | 0.004698 | 1.52 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.401e+05** | 2.020e+05 | 6.961e+05 | 1.91 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **6435** | 5682 | 1.327e+04 | 1.67 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.465e+05** | 2.096e+05 | 7.086e+05 | 1.89 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **34.96** | 32.82 | 52.7 | 1.29 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **33.51** | 21 | 154.5 | 2.77 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **313.3** | 291.7 | 471.1 | 1.28 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.986e-05** | 2.472e-05 | 1.238e-04 | 2.34 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.080e-05** | 1.739e-05 | 3.791e-05 | 1.47 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **5.066e-05** | 4.683e-05 | 1.494e-04 | 1.87 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **0.00129** | 0.001082 | 0.00482 | 2.14 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.616e-04** | 1.290e-04 | 7.235e-04 | 2.45 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **0.001551** | 0.001308 | 0.005217 | 2.03 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **2.056e+04** | 7338 | 1.208e+05 | 4.39 | | Land use | Soil quality index | pt (soil quality index) | **2.444e+05** | 2.188e+05 | 4.254e+05 | 1.41 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **0.001982** | 0.001718 | 0.003257 | 1.37 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **267.4** | 216.2 | 443.9 | 1.44 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **1.076e+06** | 9.483e+05 | 1.512e+06 | 1.28 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.7451** | 0.4631 | 1.639 | 1.9 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **4681** | -1.760e+07 | 9.203e+06 | — | Climate change 7.503e+04 kg CO2 eq per p. Main contributors: Maintenance, cogen unit 160kWe 37 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 10 %; Gas motor 206kW 7 %; Catalytic converter, three-way, 19.1 litre 7 %; Assembly, module cogen unit 160kWe 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Maintenance, cogen unit 160kWe 37 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 10 %; Gas motor 206kW 7 %; Catalytic converter, three-way, 19.1 litre 7 %; Assembly, module cogen unit 160kWe 5 %. Most sensitive exchanges (Section 6.3): Maintenance, cogen unit 160kWe [RER] (-8.4 / +10.9 %); Control cabinet cogen unit 160kWe [RER] (-4.7 / +6.1 %); Catalytic converter, three-way, 19.1 litre [RER] (-3.0 / +5.3 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 207 | 1531 | 0.135 | | Climate change-Biogenic | 261.7 | 261.7 | 1.000 | | Climate change-Fossil | 7.475e+04 | 7.475e+04 | 1.000 | | Climate change-Land use and land use change | 18.51 | 18.51 | 1.000 | | Climate change | 7.503e+04 | 7.503e+04 | 1.000 | | EF-particulate Matter | 0.002554 | 0.002554 | 1.000 | | Ecotoxicity, freshwater_inorganics | 2.401e+05 | 2.441e+05 | 0.983 | | Ecotoxicity, freshwater_organics | 6435 | 6399 | 1.006 | | Ecotoxicity, freshwater | 2.465e+05 | 2.464e+05 | 1.001 | | Eutrophication marine | 34.96 | 34.95 | 1.000 | | Eutrophication, freshwater | 33.51 | 33.51 | 1.000 | | Eutrophication, terrestrial | 313.3 | 342.3 | 0.915 | | Human toxicity, cancer_inorganics | 2.986e-05 | 2.950e-05 | 1.012 | | Human toxicity, cancer_organics | 2.080e-05 | 2.080e-05 | 1.000 | | Human toxicity, cancer | 5.066e-05 | 5.031e-05 | 1.007 | | Human toxicity, non-cancer_inorganics | 0.00129 | 0.001272 | 1.014 | | Human toxicity, non-cancer_organics | 2.616e-04 | 2.616e-04 | 1.000 | | Human toxicity, non-cancer | 0.001551 | 0.001533 | 1.012 | | Ionising radiation, human health | 2.056e+04 | 2.056e+04 | 1.000 | | Land use | 2.444e+05 | 2.057e+05 | 1.188 | | Ozone depletion | 0.001982 | 0.001982 | 1.000 | | Photochemical ozone formation - human health | 267.4 | 267.4 | 1.000 | | Resource use, fossils | 1.076e+06 | 1.076e+06 | 1.000 | | Resource use, minerals and metals | 0.7451 | 0.7409 | 1.006 | | Water use | 4681 | 5298 | 0.884 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 7.502e+04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 1.717e+08 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Maintenance, cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -8.4 / +10.9 | 12.0 (Climate change-Land use and land use change) | | Control cabinet cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -4.7 / +6.1 | 6.8 (Human toxicity, cancer_organics) | | Catalytic converter, three-way, 19.1 litre [RER] | 5 p | ×0.562 / ×1.78 | lognormal, GSD² 1.8 | -3.0 / +5.3 | 69.7 (Human toxicity, non-cancer_organics) | | Gas motor 206kW [RER] | 1.25 p | ×0.631 / ×1.59 | lognormal, GSD² 1.6 | -2.7 / +4.2 | 21.1 (Human toxicity, non-cancer_inorganics) | | Planning, cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -2.4 / +3.1 | 4.1 (Climate change-Biogenic) | | Assembly, module cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -1.2 / +1.6 | 2.8 (Climate change-Biogenic) | | Supply air input/spent air output cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -1.0 / +1.4 | 3.0 (Climate change-Land use and land use change) | | Sound insulation cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -1.0 / +1.3 | 3.1 (Water use) | | Construction work, cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.7 / +1.0 | 1.9 (Climate change-Land use and land use change) | | Operation start, cogen unit 160kWe [RER] | 1 p | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.0 / +0.0 | 0.2 (Climate change-Land use and land use change) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 7.503e+04 kg CO2 eq per p (95 % interval 6.703e+04–9.995e+04). Dominant contributors: Maintenance, cogen unit 160kWe 37 %; Control cabinet cogen unit 160kWe 21 %; Planning, cogen unit 160kWe 10 %; Gas motor 206kW 7 %; Catalytic converter, three-way, 19.1 litre 7 %; Assembly, module cogen unit 160kWe 5 %. Most sensitive: Maintenance, cogen unit 160kWe [RER] (-8.4 / +10.9 %); Control cabinet cogen unit 160kWe [RER] (-4.7 / +6.1 %); Catalytic converter, three-way, 19.1 litre [RER] (-3.0 / +5.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.8e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 7.503e+04 in [6.703e+04, 9.995e+04] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].