====== Treatment, sewage, unpolluted, to wastewater treatment, class 3 — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:treatment_sewage_unpolluted_to_wastewater_treatment_class_3__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Treatment, sewage, unpolluted, to wastewater treatment, class 3 [CH], per 1 m3. EF v3.1 climate change 0.2791 kg CO2 eq (Monte Carlo 95 % interval 0.2329–0.48). Main contributors: Sewer grid, class 3 44 %; Wastewater treatment plant, class 3 40 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 13 %. Status: final control: 0 failed, 1 warning(s) (Section 7). ^ Item ^ Value ^ | Dataset name | Treatment, sewage, unpolluted, to wastewater treatment, class 3 | | Dataset UUID / graph id | ''%%f2814ced-c83a-4b71-8506-3ba89d599de6%%'' / ''%%activity:treatment_sewage_unpolluted_to_wastewater_treatment_class_3__ch%%'' | | Reference product, unit | Treatment, sewage, unpolluted, to wastewater treatment, class 3, 1 m3 | | Location | CH | | Time period | 2000-01/2000-12 | | Category | wastewater treatment / unspecified | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control: 0 failed, 1 warning(s) (Section 7) | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Wastewater purified in a medium size municipal wastewater treatment plant (capacity class 3), with an average capacity size of 24900 per-captia-equivalents PCE. Wastewater contains (in kg/m3): ; UUID: f2814ced-c83a-4b71-8506-3ba89d599de6 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 m3** of Treatment, sewage, unpolluted, to wastewater treatment, class 3 (CH). All results are given per unit of the reference flow. ==== System boundary ==== Infrastructure materials for municipal wastewater treatment plant, transports, dismantling. Land use burdens. ==== Technology ==== Three stage wastewater treatment (mechanical, biological, chemical) including sludge digestion (fermentation) according to the average technology in Switzerland ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Sewer grid, class 3 | technosphere | CH | 2.1782e-07 | km | none declared: tdc-doc default ±50 % | — | 44.2 | █████████ | | | Wastewater treatment plant, class 3 | technosphere | CH | 5.6882e-09 | p | none declared: tdc-doc default ±50 % | — | 40.3 | ████████ | | | Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 0.0155 | kg | lognormal, GSD² 1.07 | — | 13.2 | ███ | | | Electricity, low voltage, at grid | technosphere | CH | 0.028 | kWh | lognormal, GSD² 1.1 | — | 1.0 | · | | | Natural gas, burned in boiler modulating >100kW | technosphere | RER | 0.0187 | MJ | lognormal, GSD² 1.1 | — | 0.5 | · | | | Light fuel oil, burned in boiler 100kW, non-modulating | technosphere | CH | 0.013858 | MJ | lognormal, GSD² 1.1 | — | 0.5 | · | | | Disposal, paper, 11.2% water, to municipal incineration | technosphere | CH | 0.0155 | kg | lognormal, GSD² 1.07 | — | 0.2 | · | | | Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 3.1000e-04 | tkm | lognormal, GSD² 1.05 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.1008 | MJ | lognormal, GSD² 1.1 | — | 0.0 | · | | ==== Data quality ==== 0 of 9 direct exchanges carry a declared pedigree, 7 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Gabor Doka; data entry: Roland Hischier (EMPA); validation (proof reading): Niels Jungbluth (ESU) | | extrapolations | | | sampling procedure | | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: passed.; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 2 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 m3. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **4.436e-04** | 3.924e-04 | 8.137e-04 | 1.46 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.158e-04** | 3.240e-04 | 0.00101 | 1.79 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.2786** | 0.2324 | 0.4793 | 1.44 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.830e-05** | 4.214e-05 | 9.187e-05 | 1.49 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.2791** | 0.2329 | 0.48 | 1.44 | | EF-particulate Matter | Impact on human health | disease incidence | **1.398e-08** | 1.138e-08 | 3.155e-08 | 1.72 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.5888** | 0.5523 | 1.425 | 1.61 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.01678** | 0.01549 | 0.05589 | 2.21 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.6056** | 0.5759 | 1.454 | 1.62 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **1.640e-04** | 1.435e-04 | 3.075e-04 | 1.47 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **7.011e-05** | 5.216e-05 | 5.457e-04 | 3.29 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **0.001598** | 0.001392 | 0.003021 | 1.49 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.812e-11** | 8.436e-11 | 2.536e-10 | 1.77 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.746e-11** | 3.043e-11 | 8.088e-11 | 1.66 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.256e-10** | 1.197e-10 | 3.300e-10 | 1.68 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.406e-09** | 4.168e-09 | 1.342e-08 | 1.82 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.344e-10** | 1.156e-10 | 2.707e-10 | 1.55 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.540e-09** | 4.300e-09 | 1.361e-08 | 1.8 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **0.05775** | 0.0236 | 0.3754 | 4.24 | | Land use | Soil quality index | pt (soil quality index) | **2.911** | 2.523 | 4.274 | 1.33 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **3.472e-09** | 3.187e-09 | 6.628e-09 | 1.45 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **6.182e-04** | 5.532e-04 | 0.001167 | 1.47 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **2.39** | 2.083 | 4.825 | 1.53 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.456e-06** | 1.114e-06 | 2.921e-06 | 1.65 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **0.05957** | -82.39 | 42.4 | — | Climate change 0.2791 kg CO2 eq per m3. Main contributors: Sewer grid, class 3 44 %; Wastewater treatment plant, class 3 40 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 13 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Sewer grid, class 3 44 %; Wastewater treatment plant, class 3 40 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 13 %. Most sensitive exchanges (Section 6.3): Sewer grid, class 3 [CH] (-22.1 / +22.1 %); Wastewater treatment plant, class 3 [CH] (-20.2 / +20.2 %); Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] (-0.8 / +0.9 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 4.436e-04 | 6.090e-04 | 0.728 | | Climate change-Biogenic | 4.158e-04 | 4.158e-04 | 1.000 | | Climate change-Fossil | 0.2786 | 0.2786 | 1.000 | | Climate change-Land use and land use change | 4.830e-05 | 4.830e-05 | 1.000 | | Climate change | 0.2791 | 0.2791 | 1.000 | | EF-particulate Matter | 1.398e-08 | 1.398e-08 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.5888 | 0.6041 | 0.975 | | Ecotoxicity, freshwater_organics | 0.01678 | 0.0167 | 1.005 | | Ecotoxicity, freshwater | 0.6056 | 0.6202 | 0.976 | | Eutrophication marine | 1.640e-04 | 1.640e-04 | 1.000 | | Eutrophication, freshwater | 7.011e-05 | 7.011e-05 | 1.000 | | Eutrophication, terrestrial | 0.001598 | 0.001787 | 0.894 | | Human toxicity, cancer_inorganics | 8.812e-11 | 8.762e-11 | 1.006 | | Human toxicity, cancer_organics | 3.746e-11 | 3.746e-11 | 1.000 | | Human toxicity, cancer | 1.256e-10 | 1.251e-10 | 1.004 | | Human toxicity, non-cancer_inorganics | 4.406e-09 | 4.386e-09 | 1.004 | | Human toxicity, non-cancer_organics | 1.344e-10 | 1.344e-10 | 1.000 | | Human toxicity, non-cancer | 4.540e-09 | 4.521e-09 | 1.004 | | Ionising radiation, human health | 0.05775 | 0.05775 | 1.000 | | Land use | 2.911 | 1.927 | 1.510 | | Ozone depletion | 3.472e-09 | 3.472e-09 | 1.000 | | Photochemical ozone formation - human health | 6.182e-04 | 6.182e-04 | 1.000 | | Resource use, fossils | 2.39 | 2.39 | 1.000 | | Resource use, minerals and metals | 1.456e-06 | 1.306e-06 | 1.114 | | Water use | 0.05957 | 0.06422 | 0.928 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2791 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 498.6 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Sewer grid, class 3 [CH] | 2.178e-07 km | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -22.1 / +22.1 | 40.1 (Water use) | | Wastewater treatment plant, class 3 [CH] | 5.688e-09 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -20.2 / +20.2 | 41.8 (Land use) | | Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] | 0.0155 kg | ×0.936 / ×1.07 | lognormal, GSD² 1.07 | -0.8 / +0.9 | 0.9 (Climate change-Fossil) | | Electricity, low voltage, at grid [CH] | 0.028 kWh | ×0.909 / ×1.1 | lognormal, GSD² 1.1 | -0.1 / +0.1 | 3.5 (Ionising radiation, human health) | | Natural gas, burned in boiler modulating >100kW [RER] | 0.0187 MJ | ×0.909 / ×1.1 | lognormal, GSD² 1.1 | -0.0 / +0.0 | 0.1 (Ozone depletion) | | Light fuel oil, burned in boiler 100kW, non-modulating [CH] | 0.01386 MJ | ×0.909 / ×1.1 | lognormal, GSD² 1.1 | -0.0 / +0.0 | 0.1 (Ozone depletion) | | Disposal, paper, 11.2% water, to municipal incineration [CH] | 0.0155 kg | ×0.936 / ×1.07 | lognormal, GSD² 1.07 | -0.0 / +0.0 | 0.1 (Human toxicity, cancer_inorganics) | | Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 3.100e-04 tkm | ×0.954 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Ecotoxicity, freshwater_organics) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.2791 kg CO2 eq per m3 (95 % interval 0.2329–0.48). Dominant contributors: Sewer grid, class 3 44 %; Wastewater treatment plant, class 3 40 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 13 %. Most sensitive: Sewer grid, class 3 [CH] (-22.1 / +22.1 %); Wastewater treatment plant, class 3 [CH] (-20.2 / +20.2 %); Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] (-0.8 / +0.9 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 m3 | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.6e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 20/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **WARN** | 7/9 exchanges carry a distribution (78 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.2791 in [0.2329, 0.48] | | time period declared | **PASS** | 2000-01/2000-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Doka G. (2008) Life Cycle Inventories of Waste Treatment Services. Final report ecoinvent data v2.1. Volume: 13. Issue: 0. Swiss Centre for LCI, Empa - TSL. Dübendorf, CH. Type: Measurement on site Source: CD-ROM First author: Doka G. Year: 2008 Title of anthology: Final report ecoinvent data v2.1 Place of publication: Dübendorf, CH Publisher: Swiss Centre for LCI, Empa - TSL Volume No: 13 Issue N… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].