====== Disposal, ventilation system, Alterswohnungen Geeren — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:disposal_ventilation_system_alterswohnungen_geeren__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Alterswohnungen Geeren [CH], per 1 p. EF v3.1 climate change 5880 kg CO2 eq (Monte Carlo 95 % interval 4946–7266). Main contributors: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 1 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Disposal, ventilation system, Alterswohnungen Geeren | | Dataset UUID / graph id | ''%%f2d64d5e-e9f5-4173-947d-af617fa3583c%%'' / ''%%activity:disposal_ventilation_system_alterswohnungen_geeren__ch%%'' | | Reference product, unit | Disposal, ventilation system, Alterswohnungen Geeren, 1 p | | Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. | | Time period | 2014-01/2014-12 | | Category | waste management / building demolition | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Disposal of a ventilation system for a residential care home with apartments and multi-purpose hall. The inventory is based on a building with a total heated gross floor area of 3712 m2 and a total nominal air flow of 6000 m3/h, total weight of the components: 1674 kg/Unit, building with a specific air flow rate of 1.6 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork made of galvanized steel and polyethylene tubes. It includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: f2d64d5e-e9f5-4173-947d-af617fa3583c This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Disposal, ventilation system, Alterswohnungen Geeren (CH). All results are given per unit of the reference flow. ==== System boundary ==== Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals. ==== Technology ==== Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Disposal, building, polyethylene/polypropylene products, to final disposal | technosphere | CH | 1579.8 | kg | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 81.5 | ████████████████ | | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | technosphere | CH | 1.377 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 7.0 | █ | | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 977.85 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.1 | █ | | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 401.91 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.3 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 639.95 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.0 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 431.47 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.3 | · | | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 313.7 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.9 | · | | | Disposal, ventilation system, Alterswohnungen Geeren, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.7 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 30.256 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation duct, stainless steel, s= 0.62mm | technosphere | CH | 20.471 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation equipment, central, 600-1200 m3/h | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.1 | · | | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 7.986 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | | ==== Data quality ==== 12 of 12 direct exchanges carry a declared pedigree, 12 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.17 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) | | extrapolations | none | | sampling procedure | Waste-specific calculation based on production input data | | production volume | na | | uncertainty adjustments | none | | time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **0.6659** | 0.5786 | 1.082 | 1.39 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.3494** | 0.2768 | 0.7188 | 1.63 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5880** | 4946 | 7265 | 1.22 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.06471** | 0.05598 | 0.1046 | 1.37 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **5880** | 4946 | 7266 | 1.22 | | EF-particulate Matter | Impact on human health | disease incidence | **6.169e-05** | 3.711e-05 | 1.283e-04 | 1.88 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **4095** | 3454 | 7209 | 1.47 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **31.98** | 27.76 | 59.72 | 1.5 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **4127** | 3487 | 7243 | 1.47 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **0.749** | 0.5865 | 1.295 | 1.52 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **0.4837** | 0.06041 | 14.19 | 17.5 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **5.844** | 4.515 | 10.41 | 1.55 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.823e-07** | 1.179e-07 | 1.011e-06 | 3.03 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **5.034e-08** | 4.175e-08 | 7.912e-08 | 1.4 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.326e-07** | 1.732e-07 | 1.074e-06 | 2.57 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.202e-06** | 6.301e-06 | 5.467e-05 | 3.08 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.250e-07** | 3.103e-07 | 6.978e-07 | 1.5 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **9.627e-06** | 6.730e-06 | 5.498e-05 | 2.98 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **54.94** | 21.37 | 328.1 | 4.19 | | Land use | Soil quality index | pt (soil quality index) | **2845** | -1142 | 8465 | — | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **8.066e-06** | 7.078e-06 | 1.294e-05 | 1.35 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **2.193** | 1.757 | 3.646 | 1.47 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **3577** | 3193 | 5467 | 1.32 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **4.190e-04** | 3.583e-04 | 8.286e-04 | 1.54 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **142.2** | -2.576e+04 | 1.363e+04 | — | Climate change 5880 kg CO2 eq per p. Main contributors: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 1 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 1 %. Most sensitive exchanges (Section 6.3): Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-15.5 / +19.1 %); Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-1.4 / +1.8 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-0.8 / +1.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 0.6659 | 1.498 | 0.445 | | Climate change-Biogenic | 0.3494 | 0.3494 | 1.000 | | Climate change-Fossil | 5880 | 5880 | 1.000 | | Climate change-Land use and land use change | 0.06471 | 0.06471 | 1.000 | | Climate change | 5880 | 5880 | 1.000 | | EF-particulate Matter | 6.169e-05 | 6.169e-05 | 1.000 | | Ecotoxicity, freshwater_inorganics | 4095 | 4278 | 0.957 | | Ecotoxicity, freshwater_organics | 31.98 | 31.87 | 1.003 | | Ecotoxicity, freshwater | 4127 | 4309 | 0.958 | | Eutrophication marine | 0.749 | 0.749 | 1.000 | | Eutrophication, freshwater | 0.4837 | 0.4837 | 1.000 | | Eutrophication, terrestrial | 5.844 | 7.452 | 0.784 | | Human toxicity, cancer_inorganics | 1.823e-07 | 1.820e-07 | 1.002 | | Human toxicity, cancer_organics | 5.034e-08 | 5.034e-08 | 1.000 | | Human toxicity, cancer | 2.326e-07 | 2.323e-07 | 1.001 | | Human toxicity, non-cancer_inorganics | 9.202e-06 | 9.081e-06 | 1.013 | | Human toxicity, non-cancer_organics | 4.250e-07 | 4.250e-07 | 1.000 | | Human toxicity, non-cancer | 9.627e-06 | 9.506e-06 | 1.013 | | Ionising radiation, human health | 54.94 | 54.94 | 1.000 | | Land use | 2845 | 1609 | 1.768 | | Ozone depletion | 8.066e-06 | 8.066e-06 | 1.000 | | Photochemical ozone formation - human health | 2.193 | 2.193 | 1.000 | | Resource use, fossils | 3577 | 3577 | 1.000 | | Resource use, minerals and metals | 4.190e-04 | 3.712e-04 | 1.129 | | Water use | 142.2 | 144.4 | 0.985 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 5880 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 8.283e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Disposal, building, polyethylene/polypropylene products, to final disposal [CH] | 1580 kg | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -15.5 / +19.1 | 19.1 (Climate change-Fossil) | | Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] | 1.377 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.4 / +1.8 | 13.2 (Ecotoxicity, freshwater_inorganics) | | Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 977.9 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 20.5 (Eutrophication, freshwater) | | Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 401.9 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 1.6 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 640 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 4.1 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 431.5 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.3 | 2.3 (Ionising radiation, human health) | | Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 313.7 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.2 / +0.2 | 1.3 (Eutrophication, freshwater) | | Disposal, ventilation system, Alterswohnungen Geeren, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.1 / +0.2 | 2.0 (Ionising radiation, human health) | | Disposal, ventilation duct, steel, zinc coated, s= 1.0mm [CH] | 30.26 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.3 (Ionising radiation, human health) | | Disposal, ventilation duct, stainless steel, s= 0.62mm [CH] | 20.47 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.1 (Ionising radiation, human health) | | Disposal, ventilation equipment, central, 600-1200 m3/h [CH] | 1 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.0 / +0.0 | 0.2 (Climate change-Land use and land use change) | | Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 7.986 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.0 / +0.0 | 0.1 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 5880 kg CO2 eq per p (95 % interval 4946–7266). Dominant contributors: Disposal, building, polyethylene/polypropylene products, to … 81 %; Disposal, ventilation unit 3500 m3/h, w. cross plate heat ex… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 4 %; Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 2 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 1 %. Most sensitive: Disposal, building, polyethylene/polypropylene products, to final disposal [CH] (-15.5 / +19.1 %); Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] (-1.4 / +1.8 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-0.8 / +1.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 5.2e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 12/12 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 5880 in [4946, 7266] | | time period declared | **PASS** | 2014-01/2014-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].