====== Cogen unit 50kWe, components for electricity only — RER ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:cogen_unit_50kwe_components_for_electricity_only__rer|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cogen unit 50kWe, components for electricity only [RER], per 1 p. EF v3.1 climate change 3781 kg CO2 eq (Monte Carlo 95 % interval 2900–6815). Main contributors: Electric parts of cogen unit 160kWe 63 %; Generator 200kWe 28 %; Assembly, generator and motor, cogen unit 160kWe 10 %. Status: final control: 0 failed, 1 warning(s) (Section 7). ^ Item ^ Value ^ | Dataset name | Cogen unit 50kWe, components for electricity only | | Dataset UUID / graph id | ''%%f2fccce7-83b0-3af1-a354-d95b51a5b29d%%'' / ''%%activity:cogen_unit_50kwe_components_for_electricity_only__rer%%'' | | Reference product, unit | Cogen unit 50kWe, components for electricity only, 1 p | | Location | RER — Extrapolated from data of a plant in Switzerland, assumed valid for Europe (RER). | | Time period | 1990-01/2000-12 | | Category | heat / natural gas\cogeneration\power unit\infrastructure | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control: 0 failed, 1 warning(s) (Section 7) | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== The module summarises infrastructure components of a cogeneration unit. ; UUID: f2fccce7-83b0-3af1-a354-d95b51a5b29d This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of Cogen unit 50kWe, components for electricity only (RER). All results are given per unit of the reference flow. ==== System boundary ==== The module includes all components related exclusively to electricity production. ==== Technology ==== Extrapolated from data of a 160kWe lambda=1 plant, adjusted to lean burn technology currently available on market, no catalytic converters. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Electric parts of cogen unit 160kWe | technosphere | RER | 0.414 | p | none declared: tdc-doc default ±50 % | — | 62.7 | █████████████ | | | Generator 200kWe | technosphere | RER | 0.333 | p | none declared: tdc-doc default ±50 % | — | 27.7 | ██████ | | | Assembly, generator and motor, cogen unit 160kWe | technosphere | RER | 0.267 | p | none declared: tdc-doc default ±50 % | — | 9.6 | ██ | | ==== Data quality ==== 0 of 3 direct exchanges carry a declared pedigree, 0 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Thomas Heck; data entry: Thomas Heck; validation (proof reading): Gerald Rebitzer | | extrapolations | | | sampling procedure | Operator and manufacturer information | | production volume | na | | uncertainty adjustments | | | validation details | Proof reading validation: passed; Other validation: none; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== ^ Item ^ Class ^ Value used ^ Reason ^ Effect ^ | 3 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) | ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **19.94** | 13.96 | 36.73 | 1.68 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **14.9** | 6.805 | 49.61 | 2.87 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3765** | 2885 | 6787 | 1.53 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.626** | 1.068 | 3.505 | 1.82 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **3781** | 2900 | 6815 | 1.53 | | EF-particulate Matter | Impact on human health | disease incidence | **1.179e-04** | 9.784e-05 | 2.214e-04 | 1.51 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.237e+04** | 1.06e+04 | 3.245e+04 | 1.79 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **408.3** | 327 | 885.3 | 1.67 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.278e+04** | 1.107e+04 | 3.297e+04 | 1.77 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.734** | 2.163 | 5.006 | 1.54 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **5.508** | 2.911 | 36.21 | 3.56 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **27.29** | 21.54 | 48.57 | 1.51 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.582e-06** | 1.998e-06 | 8.005e-06 | 2.03 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.909e-06** | 1.222e-06 | 5.913e-06 | 2.26 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **4.492e-06** | 3.815e-06 | 1.212e-05 | 1.8 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **2.432e-04** | 1.632e-04 | 8.054e-04 | 2.24 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.549e-05** | 8.161e-06 | 4.001e-05 | 2.21 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.587e-04** | 1.765e-04 | 8.275e-04 | 2.2 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **1201** | 349.8 | 1.001e+04 | 5.2 | | Land use | Soil quality index | pt (soil quality index) | **1.793e+04** | 1.343e+04 | 3.787e+04 | 1.69 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.545e-04** | 1.049e-04 | 3.521e-04 | 1.84 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **12.2** | 9.641 | 22.92 | 1.54 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **5.496e+04** | 4.159e+04 | 1.076e+05 | 1.61 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **0.1164** | 0.0688 | 0.2211 | 1.83 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **245.4** | -1.103e+06 | 6.391e+05 | — | Climate change 3781 kg CO2 eq per p. Main contributors: Electric parts of cogen unit 160kWe 63 %; Generator 200kWe 28 %; Assembly, generator and motor, cogen unit 160kWe 10 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Electric parts of cogen unit 160kWe 63 %; Generator 200kWe 28 %; Assembly, generator and motor, cogen unit 160kWe 10 %. Most sensitive exchanges (Section 6.3): Electric parts of cogen unit 160kWe [RER] (-31.4 / +31.4 %); Generator 200kWe [RER] (-13.9 / +13.9 %); Assembly, generator and motor, cogen unit 160kWe [RER] (-4.8 / +4.8 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 19.94 | 23.1 | 0.863 | | Climate change-Biogenic | 14.9 | 14.9 | 1.000 | | Climate change-Fossil | 3765 | 3765 | 1.000 | | Climate change-Land use and land use change | 1.626 | 1.626 | 1.000 | | Climate change | 3781 | 3781 | 1.000 | | EF-particulate Matter | 1.179e-04 | 1.179e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.237e+04 | 1.275e+04 | 0.970 | | Ecotoxicity, freshwater_organics | 408.3 | 405.7 | 1.006 | | Ecotoxicity, freshwater | 1.278e+04 | 1.314e+04 | 0.973 | | Eutrophication marine | 2.734 | 2.734 | 1.000 | | Eutrophication, freshwater | 5.508 | 5.508 | 1.000 | | Eutrophication, terrestrial | 27.29 | 28.84 | 0.946 | | Human toxicity, cancer_inorganics | 2.582e-06 | 2.560e-06 | 1.009 | | Human toxicity, cancer_organics | 1.909e-06 | 1.909e-06 | 1.000 | | Human toxicity, cancer | 4.492e-06 | 4.469e-06 | 1.005 | | Human toxicity, non-cancer_inorganics | 2.432e-04 | 2.423e-04 | 1.004 | | Human toxicity, non-cancer_organics | 1.549e-05 | 1.549e-05 | 1.000 | | Human toxicity, non-cancer | 2.587e-04 | 2.578e-04 | 1.003 | | Ionising radiation, human health | 1201 | 1201 | 1.000 | | Land use | 1.793e+04 | 1.426e+04 | 1.258 | | Ozone depletion | 1.545e-04 | 1.545e-04 | 1.000 | | Photochemical ozone formation - human health | 12.2 | 12.2 | 1.000 | | Resource use, fossils | 5.496e+04 | 5.499e+04 | 0.999 | | Resource use, minerals and metals | 0.1164 | 0.1161 | 1.002 | | Water use | 245.4 | 276.4 | 0.888 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 3781 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 8.181e+06 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Electric parts of cogen unit 160kWe [RER] | 0.414 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -31.4 / +31.4 | 42.1 (Climate change-Land use and land use change) | | Generator 200kWe [RER] | 0.333 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -13.9 / +13.9 | 45.2 (Human toxicity, non-cancer_inorganics) | | Assembly, generator and motor, cogen unit 160kWe [RER] | 0.267 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -4.8 / +4.8 | 7.9 (Water use) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 3781 kg CO2 eq per p (95 % interval 2900–6815). Dominant contributors: Electric parts of cogen unit 160kWe 63 %; Generator 200kWe 28 %; Assembly, generator and motor, cogen unit 160kWe 10 %. Most sensitive: Electric parts of cogen unit 160kWe [RER] (-31.4 / +31.4 %); Generator 200kWe [RER] (-13.9 / +13.9 %); Assembly, generator and motor, cogen unit 160kWe [RER] (-4.8 / +4.8 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 2.0e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **WARN** | 0/3 exchanges carry a distribution (0 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 3781 in [2900, 6815] | | time period declared | **PASS** | 1990-01/2000-12 | | geography is a known location code | **PASS** | RER | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Heck, T. (2007) Wärme-Kraft-Kopplung. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0. Editors: Dones R.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Heck, T. Year: 2007 Name of editors: Dones R. Title of anthology: Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent data v2.0 Place of … — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].