====== 16.667kWp, 100m2, PV system for PVT, installed on slanted roof, single-Si — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:16_667kwp_100m2_pv_system_for_pvt_installed_on_slanted_roof_single_si__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 16.667kWp, 100m2, PV system for PVT, installed on slanted roof, single-Si [CH], per 1 p. EF v3.1 climate change 1.84e+04 kg CO2 eq (Monte Carlo 95 % interval 9660–6.596e+04). Main contributors: Photovoltaic panel for PVT, single-Si, without flat glass, a… 69 %; Slanted-roof construction, mounted, on roof 12 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | 16.667kWp, 100m2, PV system for PVT, installed on slanted roof, single-Si | | Dataset UUID / graph id | ''%%f343e106-7a73-3c54-b652-f574d1caea9b%%'' / ''%%activity:16_667kwp_100m2_pv_system_for_pvt_installed_on_slanted_roof_single_si__ch%%'' | | Reference product, unit | 16.667kWp, 100m2, PV system for PVT, installed on slanted roof, single-Si, 1 p | | Location | CH — Installation in CH | | Time period | 2020-01/2020-12 | | Category | heat / pvt\heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Photovoltaic installation with a capacity of 16.7kWp for a PVT system only and a life time of 30 years installed in CH.; UUID: f343e106-7a73-3c54-b652-f574d1caea9b This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 p** of 16.667kWp, 100m2, PV system for PVT, installed on slanted roof, single-Si (CH). All results are given per unit of the reference flow. ==== System boundary ==== All components for the installation of a 16.kWp photovoltaic plant, for a PVT-system (PV modules without flat glass!) energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life. ==== Technology ==== Modern production plant. ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage | technosphere | RER | 113.69 | m2 | lognormal, GSD² 3.07 | — | 68.5 | ██████████████ | | | Slanted-roof construction, mounted, on roof | technosphere | RER | 110.38 | m2 | lognormal, GSD² 3.06 | — | 12.4 | ██ | | | Inverter, 2500W, at plant | technosphere | RER | 13.333 | p | lognormal, GSD² 3.12 | — | 10.5 | ██ | | | Electric installation, photovoltaic plant, at plant | technosphere | CH | 5.5556 | p | lognormal, GSD² 3.06 | — | 3.8 | █ | | | Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 456.4 | tkm | lognormal, GSD² 2.09 | — | 2.7 | █ | | | Transport, freight, lorry, fleet average | technosphere | RER | 2027.2 | tkm | lognormal, GSD² 2.09 | — | 2.1 | · | | | Electricity, low voltage, at grid | technosphere | CH | 1.2778 | kWh | lognormal, GSD² 1.05 | — | 0.0 | · | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 4.6 | MJ | lognormal, GSD² 1.28 | — | 0.0 | · | | ==== Data quality ==== 0 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Livia Waldburger (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | | | sampling procedure | Data provided by manufacturer and literature data on worldwide module production. | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 14.09.2020; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme_A-Konvertieren\PVT[EcoSpold_16.667kWp, 100m2, PV system for PVT, installed on slanted roof, single-Si_v0.1_lwa.xlsx]X-Process; | | time period comment | undefined | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **99.92** | 60.56 | 310.1 | 2.26 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **87.04** | 32.79 | 432.8 | 3.78 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.831e+04** | 9602 | 6.563e+04 | 2.72 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **11.11** | 6.625 | 36.63 | 2.41 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **1.84e+04** | 9660 | 6.596e+04 | 2.72 | | EF-particulate Matter | Impact on human health | disease incidence | **6.722e-04** | 4.310e-04 | 0.004885 | 3.32 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.178e+05** | 6.373e+04 | 5.271e+05 | 2.95 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2519** | 1705 | 9122 | 2.35 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **1.203e+05** | 6.586e+04 | 5.368e+05 | 2.93 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **29.57** | 14.51 | 115.8 | 2.84 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **16.68** | 9.769 | 122.2 | 3.55 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **202** | 117.3 | 746.1 | 2.54 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.352e-06** | 7.190e-06 | 4.385e-05 | 2.43 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **4.867e-06** | 2.565e-06 | 1.990e-05 | 2.81 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **1.422e-05** | 1.039e-05 | 5.676e-05 | 2.4 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **6.182e-04** | 4.608e-04 | 0.00257 | 2.38 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **3.820e-05** | 2.232e-05 | 1.040e-04 | 2.29 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **6.564e-04** | 4.924e-04 | 0.002681 | 2.35 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **4622** | 1327 | 5.048e+04 | 5.91 | | Land use | Soil quality index | pt (soil quality index) | **1.344e+05** | 7.275e+04 | 5.489e+05 | 2.9 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **5.945e-04** | 3.581e-04 | 0.002137 | 2.59 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **69.02** | 41.85 | 243.3 | 2.42 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **2.423e+05** | 1.354e+05 | 8.902e+05 | 2.66 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.211** | 0.6252 | 3.296 | 2.42 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **1.538e+04** | -5.760e+06 | 3.716e+06 | — | Climate change 1.84e+04 kg CO2 eq per p. Main contributors: Photovoltaic panel for PVT, single-Si, without flat glass, a… 69 %; Slanted-roof construction, mounted, on roof 12 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Photovoltaic panel for PVT, single-Si, without flat glass, a… 69 %; Slanted-roof construction, mounted, on roof 12 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. Most sensitive exchanges (Section 6.3): Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage [RER] (-45.7 / +137.2 %); Slanted-roof construction, mounted, on roof [RER] (-8.3 / +24.7 %); Inverter, 2500W, at plant [RER] (-7.1 / +21.6 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 99.92 | 104.5 | 0.956 | | Climate change-Biogenic | 87.04 | 87.04 | 1.000 | | Climate change-Fossil | 1.831e+04 | 1.831e+04 | 1.000 | | Climate change-Land use and land use change | 11.11 | 11.11 | 1.000 | | Climate change | 1.84e+04 | 1.84e+04 | 1.000 | | EF-particulate Matter | 6.722e-04 | 6.722e-04 | 1.000 | | Ecotoxicity, freshwater_inorganics | 1.178e+05 | 1.208e+05 | 0.975 | | Ecotoxicity, freshwater_organics | 2519 | 2204 | 1.143 | | Ecotoxicity, freshwater | 1.203e+05 | 1.228e+05 | 0.979 | | Eutrophication marine | 29.57 | 29.57 | 1.000 | | Eutrophication, freshwater | 16.68 | 16.68 | 1.000 | | Eutrophication, terrestrial | 202 | 209.5 | 0.964 | | Human toxicity, cancer_inorganics | 9.352e-06 | 9.305e-06 | 1.005 | | Human toxicity, cancer_organics | 4.867e-06 | 4.866e-06 | 1.000 | | Human toxicity, cancer | 1.422e-05 | 1.417e-05 | 1.003 | | Human toxicity, non-cancer_inorganics | 6.182e-04 | 6.159e-04 | 1.004 | | Human toxicity, non-cancer_organics | 3.820e-05 | 3.819e-05 | 1.000 | | Human toxicity, non-cancer | 6.564e-04 | 6.541e-04 | 1.004 | | Ionising radiation, human health | 4622 | 4622 | 1.000 | | Land use | 1.344e+05 | 1.079e+05 | 1.246 | | Ozone depletion | 5.945e-04 | 5.945e-04 | 1.000 | | Photochemical ozone formation - human health | 69.02 | 69.02 | 1.000 | | Resource use, fossils | 2.423e+05 | 2.423e+05 | 1.000 | | Resource use, minerals and metals | 1.211 | 1.2 | 1.009 | | Water use | 1.538e+04 | 1.539e+04 | 0.999 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 1.838e+04 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 4.063e+07 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage [RER] | 113.7 m2 | ×0.333 / ×3 | lognormal, GSD² 3.07 | -45.7 / +137.2 | 192.6 (Water use) | | Slanted-roof construction, mounted, on roof [RER] | 110.4 m2 | ×0.334 / ×2.99 | lognormal, GSD² 3.06 | -8.3 / +24.7 | 47.4 (Ionising radiation, human health) | | Inverter, 2500W, at plant [RER] | 13.33 p | ×0.328 / ×3.05 | lognormal, GSD² 3.12 | -7.1 / +21.6 | 100.9 (Resource use, minerals and metals) | | Electric installation, photovoltaic plant, at plant [CH] | 5.556 p | ×0.334 / ×2.99 | lognormal, GSD² 3.06 | -2.5 / +7.5 | 70.8 (Human toxicity, non-cancer_organics) | | Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 456.4 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -1.4 / +2.8 | 13.5 (Ozone depletion) | | Transport, freight, lorry, fleet average [RER] | 2027 tkm | ×0.486 / ×2.06 | lognormal, GSD² 2.09 | -1.1 / +2.2 | 14.0 (Climate change-Land use and land use change) | | Electricity, low voltage, at grid [CH] | 1.278 kWh | ×0.953 / ×1.05 | lognormal, GSD² 1.05 | -0.0 / +0.0 | 0.0 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 1.84e+04 kg CO2 eq per p (95 % interval 9660–6.596e+04). Dominant contributors: Photovoltaic panel for PVT, single-Si, without flat glass, a… 69 %; Slanted-roof construction, mounted, on roof 12 %; Inverter, 2500W, at plant 11 %; Electric installation, photovoltaic plant, at plant 4 %; Transport, freight, lorry, 3.5t gross weight, fleet average 3 %; Transport, freight, lorry, fleet average 2 %. Most sensitive: Photovoltaic panel for PVT, single-Si, without flat glass, at regional storage [RER] (-45.7 / +137.2 %); Slanted-roof construction, mounted, on roof [RER] (-8.3 / +24.7 %); Inverter, 2500W, at plant [RER] (-7.1 / +21.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 p | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 23/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 1.84e+04 in [9660, 6.596e+04] | | time period declared | **PASS** | 2020-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].