====== Heat, at borehole heat pump, brine-water, 50kW, cert. electr., in new building — CH ====== //Dataset documentation and final control (tdc-doc, imported mode)// \\ [[bafuq>activity:heat_at_borehole_heat_pump_brine_water_50kw_cert_electr_in_new_building__ch|Open this dataset in OpenData]] > **Abstract.** BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Heat, at borehole heat pump, brine-water, 50kW, cert. electr., in new building [CH], per 1 MJ. EF v3.1 climate change 0.003928 kg CO2 eq (Monte Carlo 95 % interval 0.003065–0.007312). Main contributors: Borehole heat exchanger, 300m 28 %; Pentafluoroethane 24 %; Electricity, low voltage, certified electricity, at grid 19 %; Disposal, heat pump, brine-water, 50kW 14 %; Heat pump, brine-water, 50kW 10 %; Difluoromethane 5 %. Status: final control passed. ^ Item ^ Value ^ | Dataset name | Heat, at borehole heat pump, brine-water, 50kW, cert. electr., in new building | | Dataset UUID / graph id | ''%%fec85012-938b-3408-8695-5ecff78e1452%%'' / ''%%activity:heat_at_borehole_heat_pump_brine_water_50kw_cert_electr_in_new_building__ch%%'' | | Reference product, unit | Heat, at borehole heat pump, brine-water, 50kW, cert. electr., in new building, 1 MJ | | Location | CH — Data apply to the supply in Switzerland. | | Time period | 2019-01/2020-12 | | Category | heat / heat pumps\heating systems | | Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 | | Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) | | Background database | BAFU 2026 v1 (graph ''%%bafuquery-db%%'') | | LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) | | Status | final control passed | | Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 | ===== Introduction ===== Heat from a brine-water heat pump, 50kW with heat source form borehole, 150m deep and cerified electricity mix (CH). Lifetime of the heat pump is 20 years, the borehole 50years. SPF=5.5. Loss of coolant is 2% (of the total amount in the system) per year.; UUID: fec85012-938b-3408-8695-5ecff78e1452 This report documents an **imported** dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares. ===== Goal and scope ===== ==== Function, functional unit and reference flow ==== Reference flow: **1 MJ** of Heat, at borehole heat pump, brine-water, 50kW, cert. electr., in new building (CH). All results are given per unit of the reference flow. ==== System boundary ==== Included are the share of the production of the brine-water heatpump with a lifetime of 20years scaled for 1MJ. Also the borehole with the geothermal proble with a lifetime of at least 50years is part of this process. ==== Technology ==== undefined ==== Link to the background database ==== Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load). ==== LCIA method ==== EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place. ===== Life cycle inventory ===== ==== Inventory table ==== Direct exchanges per reference flow, ordered by their share of climate change. //Uncertainty//: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). //Pedigree//: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise). ^ Exchange ^ Type ^ Location / compartment ^ Amount ^ Unit ^ Uncertainty ^ Pedigree ^ GWP share (%) ^ ^ Notes ^ | Borehole heat exchanger, 300m | technosphere | CH | 1.7637e-07 | unit | lognormal, GSD² 3.05 | — | 27.7 | ██████ | | | Electricity, low voltage, certified electricity, at grid | technosphere | CH | 0.050505 | kWh | lognormal, GSD² 1.22 | — | 18.6 | ████ | | | Disposal, heat pump, brine-water, 50kW | technosphere | CH | 1.3228e-07 | p | lognormal, GSD² 3.05 | — | 14.3 | ███ | | | Heat pump, brine-water, 50kW | technosphere | RER | 1.3228e-07 | p | lognormal, GSD² 3.05 | — | 10.1 | ██ | | | Trifluoromethane, at plant | technosphere | GLO | 2.5397e-07 | kg | lognormal, GSD² 2.29 | — | 0.1 | · | | | 1,1-difluoroethane, HFC-152a, at plant | technosphere | US | 2.5397e-07 | kg | lognormal, GSD² 2.29 | — | 0.0 | · | | | Pentafluoroethane | elementary | air/Ground level / Urban (>1000 people/s… | 2.5397e-07 | kg | lognormal, GSD² 1.56 | — | 24.2 | █████ | | | Difluoromethane | elementary | air/Ground level / Urban (>1000 people/s… | 2.5397e-07 | kg | lognormal, GSD² 1.56 | — | 5.0 | █ | | | Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 0.18182 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | | Energy, Geothermal, Converted | elementary | natural resource | 0.81818 | MJ | lognormal, GSD² 1.22 | — | 0.0 | · | | ==== Data quality ==== 0 of 10 direct exchanges carry a declared pedigree, 10 carry a distribution. ^ Field ^ As declared by the publisher ^ | Data generator / entry / validation | data generator: Cyrill Kern (CARBOTECH); data entry: Thomas Kaegi (CARBOTECH); validation (proof reading): Andy Spoerri (EBP) | | extrapolations | none | | sampling procedure | heat efficieny based on literature | | production volume | na | | uncertainty adjustments | none | | validation details | Proof reading validation: 19.02.2021; Other validation: Z:\Schreibtisch\WinShare\BAFU Heizsysteme\A_zum konvertieren\WP[EcoSpold_heat at borehole heat pump_15-50kW_certified electricity mix_v0.1_lwa.xlsx]X-Process; | | time period comment | Time of publications. | ==== Data gaps, proxies and assumptions ==== None recorded. ===== Life cycle impact assessment (EF v3.1) ===== Per 1 MJ. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4. ^ Impact category ^ Indicator ^ Unit ^ Result ^ 2.5 % ^ 97.5 % ^ GSD² ^ | Acidification | Accumulated Exceedance (AE) | mol H+ eq | **9.959e-06** | 6.969e-06 | 2.334e-05 | 1.88 | | Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.667e-05** | 3.425e-05 | 7.285e-05 | 1.47 | | Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.00384** | 0.002991 | 0.007197 | 1.57 | | Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **4.113e-05** | 2.634e-05 | 6.728e-05 | 1.62 | | Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | **0.003928** | 0.003065 | 0.007312 | 1.55 | | EF-particulate Matter | Impact on human health | disease incidence | **8.923e-11** | 7.118e-11 | 2.120e-10 | 1.74 | | Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008145** | 0.006387 | 0.02507 | 2.03 | | Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **2.561e-04** | 1.797e-04 | 7.992e-04 | 2.11 | | Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | **0.008401** | 0.006591 | 0.02574 | 2.02 | | Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | **2.425e-06** | 1.585e-06 | 6.748e-06 | 2.06 | | Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | **2.898e-06** | 1.667e-06 | 2.350e-05 | 3.82 | | Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | **2.504e-05** | 1.739e-05 | 6.170e-05 | 1.9 | | Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **1.337e-12** | 1.049e-12 | 5.028e-12 | 2.19 | | Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **9.791e-13** | 7.174e-13 | 2.131e-12 | 1.76 | | Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **2.316e-12** | 1.945e-12 | 6.763e-12 | 1.87 | | Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.908e-11** | 6.309e-11 | 3.753e-10 | 2.48 | | Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | **8.551e-12** | 4.934e-12 | 2.207e-11 | 2.17 | | Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | **9.763e-11** | 7.262e-11 | 3.893e-10 | 2.41 | | Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | **2.943e-04** | 1.132e-04 | 0.002394 | 4.5 | | Land use | Soil quality index | pt (soil quality index) | **0.03152** | 0.02189 | 0.05967 | 1.69 | | Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | **1.216e-09** | 4.679e-10 | 4.352e-09 | 3.14 | | Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | **8.993e-06** | 5.760e-06 | 2.460e-05 | 2.1 | | Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | **0.02672** | 0.01652 | 0.07351 | 2.16 | | Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | **1.890e-07** | 9.122e-08 | 7.032e-07 | 2.89 | | Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | **1.525e-04** | -1.724 | 0.8047 | — | Climate change 0.003928 kg CO2 eq per MJ. Main contributors: Borehole heat exchanger, 300m 28 %; Pentafluoroethane 24 %; Electricity, low voltage, certified electricity, at grid 19 %; Disposal, heat pump, brine-water, 50kW 14 %; Heat pump, brine-water, 50kW 10 %; Difluoromethane 5 %. ===== Interpretation ===== ==== Significant issues ==== Direct exchanges dominating climate change: Borehole heat exchanger, 300m 28 %; Pentafluoroethane 24 %; Electricity, low voltage, certified electricity, at grid 19 %; Disposal, heat pump, brine-water, 50kW 14 %; Heat pump, brine-water, 50kW 10 %; Difluoromethane 5 %. Most sensitive exchanges (Section 6.3): Borehole heat exchanger, 300m [CH] (-18.4 / +54.9 %); Disposal, heat pump, brine-water, 50kW [CH] (-9.5 / +28.3 %); Heat pump, brine-water, 50kW [RER] (-6.7 / +20.0 %). ==== Independent recalculation ==== Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026): ^ Category ^ Graph ^ Published ^ Graph / published ^ | Acidification | 9.959e-06 | 1.246e-05 | 0.799 | | Climate change-Biogenic | 4.667e-05 | 4.667e-05 | 1.000 | | Climate change-Fossil | 0.00384 | 0.00384 | 1.000 | | Climate change-Land use and land use change | 4.113e-05 | 4.113e-05 | 1.000 | | Climate change | 0.003928 | 0.003928 | 1.000 | | EF-particulate Matter | 8.923e-11 | 8.923e-11 | 1.000 | | Ecotoxicity, freshwater_inorganics | 0.008145 | 0.008381 | 0.972 | | Ecotoxicity, freshwater_organics | 2.561e-04 | 2.469e-04 | 1.037 | | Ecotoxicity, freshwater | 0.008401 | 0.008582 | 0.979 | | Eutrophication marine | 2.425e-06 | 2.425e-06 | 1.000 | | Eutrophication, freshwater | 2.898e-06 | 2.898e-06 | 1.000 | | Eutrophication, terrestrial | 2.504e-05 | 2.757e-05 | 0.908 | | Human toxicity, cancer_inorganics | 1.337e-12 | 1.331e-12 | 1.004 | | Human toxicity, cancer_organics | 9.791e-13 | 9.791e-13 | 1.000 | | Human toxicity, cancer | 2.316e-12 | 2.310e-12 | 1.003 | | Human toxicity, non-cancer_inorganics | 8.908e-11 | 8.875e-11 | 1.004 | | Human toxicity, non-cancer_organics | 8.551e-12 | 8.551e-12 | 1.000 | | Human toxicity, non-cancer | 9.763e-11 | 9.730e-11 | 1.003 | | Ionising radiation, human health | 2.943e-04 | 2.943e-04 | 1.000 | | Land use | 0.03152 | 0.02442 | 1.291 | | Ozone depletion | 1.216e-09 | 1.216e-09 | 1.000 | | Photochemical ozone formation - human health | 8.993e-06 | 8.993e-06 | 1.000 | | Resource use, fossils | 0.02672 | 0.02673 | 1.000 | | Resource use, minerals and metals | 1.890e-07 | 1.882e-07 | 1.005 | | Water use | 1.525e-04 | 1.775e-04 | 0.859 | | Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | | | | | Also published by BAFU for this dataset: IPCC 2021 GWP100 0.003925 kg CO2 eq; Ecological Scarcity | | | | | 2021 total 11.38 UBP. | | | | ==== Sensitivity check ==== One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean. ^ Exchange ^ Base ^ Low / high ^ Range ^ Δ GWP100 (%) ^ Δ other categories (max %) ^ | Borehole heat exchanger, 300m [CH] | 1.764e-07 unit | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -18.4 / +54.9 | 129.3 (Resource use, fossils) | | Disposal, heat pump, brine-water, 50kW [CH] | 1.323e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -9.5 / +28.3 | 28.9 (Climate change-Fossil) | | Heat pump, brine-water, 50kW [RER] | 1.323e-07 p | ×0.335 / ×2.98 | lognormal, GSD² 3.05 | -6.7 / +20.0 | 143.6 (Resource use, minerals and metals) | | Pentafluoroethane [air/Ground level / Urban (>1000 people/square mile)] | 2.540e-07 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -8.5 / +13.2 | 13.5 (Climate change-Fossil) | | Electricity, low voltage, certified electricity, at grid [CH] | 0.05051 kWh | ×0.826 / ×1.21 | lognormal, GSD² 1.22 | -3.2 / +3.9 | 20.9 (Climate change-Land use and land use change) | | Difluoromethane [air/Ground level / Urban (>1000 people/square mile)] | 2.540e-07 kg | ×0.647 / ×1.55 | lognormal, GSD² 1.56 | -1.8 / +2.7 | 2.8 (Climate change-Fossil) | | Trifluoromethane, at plant [GLO] | 2.540e-07 kg | ×0.445 / ×2.25 | lognormal, GSD² 2.29 | -0.0 / +0.1 | 33.3 (Ozone depletion) | | 1,1-difluoroethane, HFC-152a, at plant [US] | 2.540e-07 kg | ×0.445 / ×2.25 | lognormal, GSD² 2.29 | -0.0 / +0.0 | 0.2 (Ionising radiation, human health) | ==== Uncertainty analysis ==== Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5. ==== Comparison with other data ==== No other location of this dataset in the graph. ==== Conclusions and limitations ==== GWP100 0.003928 kg CO2 eq per MJ (95 % interval 0.003065–0.007312). Dominant contributors: Borehole heat exchanger, 300m 28 %; Pentafluoroethane 24 %; Electricity, low voltage, certified electricity, at grid 19 %; Disposal, heat pump, brine-water, 50kW 14 %; Heat pump, brine-water, 50kW 10 %; Difluoromethane 5 %. Most sensitive: Borehole heat exchanger, 300m [CH] (-18.4 / +54.9 %); Disposal, heat pump, brine-water, 50kW [CH] (-9.5 / +28.3 %); Heat pump, brine-water, 50kW [RER] (-6.7 / +20.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6. ===== Final control ===== ^ Item ^ Status ^ Detail ^ | reference flow | **PASS** | production amount 1.0 MJ | | closure: sum of direct contributions = dataset score (all 25 categories) | **PASS** | largest relative gap 3.5e-16 | | independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | **PASS** | graph / published = 1; categories within ±5 %: 21/25 | | every technosphere input of the EcoSpold delivery is in the graph | **PASS** | all present (bafu_links_check.py) | | uncertainty declared on the direct exchanges | **PASS** | 10/10 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values | | Monte Carlo 95 % interval contains the deterministic score | **PASS** | 0.003928 in [0.003065, 0.007312] | | time period declared | **PASS** | 2019-01/2020-12 | | geography is a known location code | **PASS** | CH | | sources cited | **PASS** | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them | ===== References ===== - Kägi Thomas, Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber (2020) LCI of heating systems. Carbotech im Auftrag des BAFU. Carbotech AG. Zürich. CH. Type: Separate publication Source: Report First author: Kägi Thomas Other authors: Livia Waldburger, Cyril Kern, Gavin Roberts, Mischa Zschokke, Flora Conte, Lea Weber Year: 2020 Title of anthology: Carbotech im Au… — //published source; as declared by BAFU (not found in OpenAlex/Crossref)// - Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — //database; dataset citation// - International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva. - Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. //(tdc-doc method reference; title, version and year to verify against the user's copy)// - European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra. - Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236 ===== Annex — licence and terms of use ===== BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required. ---- To suggest a correction or a dataset that does not exist yet, use [[proposals:start|Propose a dataset]].