Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system, Pflegezentrum Witikon [CH], per 1 p. EF v3.1 climate change 1.033e+04 kg CO2 eq (Monte Carlo 95 % interval 9363–1.261e+04). Main contributors: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Disposal, ventilation system, Pflegezentrum Witikon |
| Dataset UUID / graph id | 041e12fb-6361-40ef-9a9f-5e383f3dae12 / activity:disposal_ventilation_system_pflegezentrum_witikon__ch |
| Reference product, unit | Disposal, ventilation system, Pflegezentrum Witikon, 1 p |
| Location | CH — Specific to the technology mix encountered in sorting plants in Switzerland. |
| Time period | 2014-01/2014-12 |
| Category | waste management / building demolition |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Disposal of a ventilation system for a residential care home with apartments, kitchen, cafe/restaurant, multi-purpose hall, laundry and car park. The inventory is based on a building with a total heated gross floor area of 11358 m2 and a total nominal air flow of 74580 m3/h, total weight of the components: 30520 kg/Unit, building with a specific air flow rate of 6.6 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: 041e12fb-6361-40ef-9a9f-5e383f3dae12
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 p of Disposal, ventilation system, Pflegezentrum Witikon (CH). All results are given per unit of the reference flow.
Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.
Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger | technosphere | CH | 4.635 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 37.6 | ████████ | |
| Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 4730 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 7.4 | █ | |
| Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 2735 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.6 | █ | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.75mm | technosphere | CH | 2870.5 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 5.1 | █ | |
| Disposal, silencer for ventilator unit 13000 m3/h, modular | technosphere | CH | 20.54 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 5.0 | █ | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.62mm | technosphere | CH | 2832.2 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.9 | █ | |
| Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.8 | █ | |
| Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer | technosphere | CH | 1 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 3.5 | █ | |
| Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger | technosphere | CH | 0.977 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.8 | █ | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm | technosphere | CH | 868.65 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.8 | █ | |
| Disposal, ventilation duct, steel, zinc coated, s= 0.87mm | technosphere | CH | 1446.4 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.6 | █ | |
| Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger | technosphere | CH | 1.378 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.5 | · | |
| Disposal, ventilation system, Pflegezentrum Witikon, various components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.1 | · | |
| Disposal, ventilation unit 3500 m3/h, w. circuit connected heat exchanger | technosphere | CH | 0.717 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.0 | · | |
| Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer | technosphere | CH | 1.694 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.9 | · | |
| Disposal, EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil | technosphere | CH | 485 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.4 | · | |
| Disposal, silencer for ventilator unit 3500 m3/h, modular | technosphere | CH | 10.164 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.3 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.0mm | technosphere | CH | 667.21 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.2 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.5mm | technosphere | CH | 379.07 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.8 | · | |
| Disposal, silencer for ventilator unit 6700 m3/h, modular, Device | technosphere | CH | 4 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.7 | · | |
| Disposal, ventilation duct, steel, zinc coated, s= 1.25mm | technosphere | CH | 331.1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | |
| Disposal, thermal insulation, 100mm, 40kg/m3, alumium cladding | technosphere | CH | 735 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.6 | · | |
| Disposal, silencer for ventilator unit 1800 m3/h, modular, Device | technosphere | CH | 5.512 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.5 | · | |
| Disposal, thermal insulation, 100mm, 40kg/m3, reinforced alumium foil | technosphere | CH | 174 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.4 | · | |
| Disposal, ventilation duct, stainless steel, s= 1.25mm | technosphere | CH | 155.14 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Disposal, ventilation duct, stainless steel, s= 1.0mm | technosphere | CH | 119 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Disposal, ventilation system, Pflegezentrum Witikon, special components | technosphere | CH | 1 | p | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Disposal, ventilation duct, stainless steel, s= 1.5mm | technosphere | CH | 66.6 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Disposal, ventilation duct, stainless steel, s= 0.87mm | technosphere | CH | 61 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Disposal, ventilation duct, stainless steel, s= 0.62mm | technosphere | CH | 30 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.6mm | technosphere | CH | 6.0781 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | |
| Disposal, ventilation duct, stainless steel, s= 0.75mm | technosphere | CH | 10.6 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · |
32 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.34 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Waste-specific calculation based on production input data |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2013. Disposal technology mix as used in late 1990ies |
None recorded.
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 3.287 | 2.975 | 6.68 | 1.51 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 2.219 | 1.777 | 4.371 | 1.58 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.033e+04 | 9360 | 1.261e+04 | 1.17 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.4064 | 0.3552 | 0.6264 | 1.33 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 1.033e+04 | 9363 | 1.261e+04 | 1.17 |
| EF-particulate Matter | Impact on human health | disease incidence | 3.077e-04 | 1.960e-04 | 6.468e-04 | 1.81 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 4.263e+04 | 3.354e+04 | 6.923e+04 | 1.46 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 183.7 | 161.9 | 340.5 | 1.49 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 4.281e+04 | 3.373e+04 | 6.946e+04 | 1.46 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 3.817 | 3.084 | 8.643 | 1.69 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 2.428 | 0.3449 | 66.79 | 16.6 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 26.97 | 21.1 | 66.63 | 1.8 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 5.194e-07 | 5.198e-07 | 2.049e-06 | 2.01 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.674e-07 | 2.302e-07 | 4.124e-07 | 1.35 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 7.867e-07 | 8.032e-07 | 2.387e-06 | 1.73 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.165e-05 | 3.078e-05 | 1.157e-04 | 1.95 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.231e-06 | 1.761e-06 | 3.475e-06 | 1.42 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 3.388e-05 | 3.310e-05 | 1.184e-04 | 1.9 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 365.3 | 140.2 | 2227 | 4.14 |
| Land use | Soil quality index | pt (soil quality index) | 1.623e+04 | -3820 | 4.254e+04 | — |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 4.337e-05 | 3.968e-05 | 7.124e-05 | 1.34 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 10.54 | 8.649 | 23.79 | 1.64 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 1.98e+04 | 1.831e+04 | 3.203e+04 | 1.33 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.002561 | 0.002201 | 0.005069 | 1.52 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 1401 | -1.589e+05 | 8.474e+04 | — |
Climate change 1.033e+04 kg CO2 eq per p. Main contributors: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %.
Direct exchanges dominating climate change: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-7.6 / +9.5 %); Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] (-1.4 / +1.7 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-1.3 / +1.6 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 3.287 | 7.074 | 0.465 |
| Climate change-Biogenic | 2.219 | 2.219 | 1.000 |
| Climate change-Fossil | 1.033e+04 | 1.033e+04 | 1.000 |
| Climate change-Land use and land use change | 0.4064 | 0.4064 | 1.000 |
| Climate change | 1.033e+04 | 1.033e+04 | 1.000 |
| EF-particulate Matter | 3.077e-04 | 3.077e-04 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 4.263e+04 | 4.452e+04 | 0.958 |
| Ecotoxicity, freshwater_organics | 183.7 | 183.1 | 1.003 |
| Ecotoxicity, freshwater | 4.281e+04 | 4.47e+04 | 0.958 |
| Eutrophication marine | 3.817 | 3.817 | 1.000 |
| Eutrophication, freshwater | 2.428 | 2.428 | 1.000 |
| Eutrophication, terrestrial | 26.97 | 34.2 | 0.789 |
| Human toxicity, cancer_inorganics | 5.194e-07 | 5.177e-07 | 1.003 |
| Human toxicity, cancer_organics | 2.674e-07 | 2.674e-07 | 1.000 |
| Human toxicity, cancer | 7.867e-07 | 7.851e-07 | 1.002 |
| Human toxicity, non-cancer_inorganics | 3.165e-05 | 3.149e-05 | 1.005 |
| Human toxicity, non-cancer_organics | 2.231e-06 | 2.231e-06 | 1.000 |
| Human toxicity, non-cancer | 3.388e-05 | 3.372e-05 | 1.005 |
| Ionising radiation, human health | 365.3 | 365.3 | 1.000 |
| Land use | 1.623e+04 | 9356 | 1.735 |
| Ozone depletion | 4.337e-05 | 4.337e-05 | 1.000 |
| Photochemical ozone formation - human health | 10.54 | 10.54 | 1.000 |
| Resource use, fossils | 1.98e+04 | 1.98e+04 | 1.000 |
| Resource use, minerals and metals | 0.002561 | 0.00219 | 1.169 |
| Water use | 1401 | 1413 | 0.991 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 1.033e+04 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 2.215e+07 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] | 4.635 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -7.6 / +9.5 | 15.1 (Water use) |
| Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] | 4730 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.4 / +1.7 | 4.0 (Eutrophication, freshwater) |
| Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] | 2735 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.3 / +1.6 | 11.4 (Eutrophication, freshwater) |
| Disposal, silencer for ventilator unit 13000 m3/h, modular [CH] | 20.54 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.0 / +1.3 | 2.5 (Eutrophication marine) |
| Disposal, ventilation unit 6700 m3/h, w. circuit connected heat exchanger [CH] | 1 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.0 / +1.2 | 1.7 (Water use) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.75mm [CH] | 2870 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.0 / +1.2 | 2.8 (Ionising radiation, human health) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.62mm [CH] | 2832 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.9 / +1.2 | 2.3 (Ionising radiation, human health) |
| Disposal, ventilator unit 13000 m3/h, modular, w. filter, without silencer [CH] | 1 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.7 / +0.9 | 1.5 (Water use) |
| Disposal, ventilation unit 3500 m3/h, w. cross plate heat excanger [CH] | 0.977 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.6 / +0.7 | 0.9 (Water use) |
| Disposal, spiral-seam duct, steel, zinc coated, s= 0.5mm [CH] | 868.6 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.7 | 0.7 (Climate change-Fossil) |
| Disposal, ventilation unit 1800 m3/h, w. cross plate heat excanger [CH] | 1.378 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 0.7 (Human toxicity, cancer_inorganics) |
| Disposal, ventilation duct, steel, zinc coated, s= 0.87mm [CH] | 1446 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 1.6 (Ionising radiation, human health) |
| Disposal, ventilation unit 3500 m3/h, w. circuit connected heat exchanger [CH] | 0.717 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.4 / +0.5 | 0.7 (Water use) |
| Disposal, ventilator unit 3500 m3/h, modular, w. filter, without silencer [CH] | 1.694 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.4 / +0.5 | 0.7 (Water use) |
| Disposal, ventilation system, Pflegezentrum Witikon, various components [CH] | 1 p | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.4 / +0.5 | 0.9 (Ionising radiation, human health) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 1.033e+04 kg CO2 eq per p (95 % interval 9363–1.261e+04). Dominant contributors: Disposal, ventilation unit 13000 m3/h, w. circuit connected … 38 %; Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alum… 7 %; Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced … 7 %; Disposal, ventilation duct, steel, zinc coated, s= 0.75mm 5 %; Disposal, silencer for ventilator unit 13000 m3/h, modular 5 %; Disposal, ventilation duct, steel, zinc coated, s= 0.62mm 5 %. Most sensitive: Disposal, ventilation unit 13000 m3/h, w. circuit connected heat exchanger [CH] (-7.6 / +9.5 %); Disposal, thermal insulation, 30mm, 40kg/m3, reinforced alumium foil [CH] (-1.4 / +1.7 %); Disposal, EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil [CH] (-1.3 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 5.3e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 21/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 1.033e+04 in [9363, 1.261e+04] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.