Table of Contents

xxx Electricity, production mix ENTSO — ENTSO-E

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Electricity, production mix ENTSO [ENTSO-E], per 1 kWh. EF v3.1 climate change 0.4254 kg CO2 eq (Monte Carlo 95 % interval 0.4135–0.4951). Main contributors: xxx Electricity, production mix DE 23 %; xxx Electricity, production mix GB 14 %; xxx Electricity, production mix IT 11 %; xxx Electricity, production mix PL 10 %; xxx Electricity, production mix ES 9 %; xxx Electricity, production mix GR 4 %. Status: final control passed.
Item Value
Dataset name xxx Electricity, production mix ENTSO
Dataset UUID / graph id 1a16679b-cf4a-4c51-b2eb-f55d460a123f / activity:xxx_electricity_production_mix_entso__entso_e
Reference product, unit xxx Electricity, production mix ENTSO, 1 kWh
Location ENTSO-E — Data apply to public and self producers in ENTSO-E network / Europe
Time period 9999-01/9999-12
Category electricity / notMaintained
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Electricity net production shares are based on an annual average for the year 2008 according to IEA Electricity Information.; UUID: 1a16679b-cf4a-4c51-b2eb-f55d460a123f

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of xxx Electricity, production mix ENTSO (ENTSO-E). All results are given per unit of the reference flow.

System boundary

It includes shares of national electricity production ENTSO-E member countries (in 2008) at the busbar. It does not include transformation, transport nor distribution losses.

Technology

No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current (2004) average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
xxx Electricity, production mix DE technosphere DE 0.1726 kWh lognormal, GSD² 1.05 — 22.9 █████
xxx Electricity, production mix GB technosphere GB 0.10601 kWh lognormal, GSD² 1.05 — 14.4 ███
xxx Electricity, production mix IT technosphere IT 0.086461 kWh lognormal, GSD² 1.05 — 10.9 ██
xxx Electricity, production mix PL technosphere PL 0.038856 kWh lognormal, GSD² 1.05 — 9.5 ██
xxx Electricity, production mix ES technosphere ES 0.086898 kWh lognormal, GSD² 1.05 — 9.3 ██
xxx Electricity, production mix GR technosphere GR 0.016688 kWh lognormal, GSD² 1.05 — 3.6 █
xxx Electricity, production mix NL technosphere NL 0.028924 kWh lognormal, GSD² 1.05 — 3.6 █
xxx Electricity, production mix CZ technosphere CZ 0.022271 kWh lognormal, GSD² 1.05 — 3.6 █
xxx Electricity, production mix FR technosphere FR 0.15903 kWh lognormal, GSD² 1.05 — 3.3 █
xxx Electricity, production mix RO technosphere RO 0.017025 kWh lognormal, GSD² 1.05 — 2.2 ·
xxx Electricity, production mix CS technosphere CS 0.010013 kWh lognormal, GSD² 1.05 — 2.1 ·
xxx Electricity, production mix BG technosphere BG 0.011873 kWh lognormal, GSD² 1.05 — 1.8 ·
xxx Electricity, production mix PT technosphere PT 0.01288 kWh lognormal, GSD² 1.05 — 1.6 ·
xxx Electricity, production mix FI technosphere FI 0.021706 kWh lognormal, GSD² 1.05 — 1.5 ·
xxx Electricity, production mix DK technosphere DK 0.010191 kWh lognormal, GSD² 1.05 — 1.5 ·
xxx Electricity, production mix BE technosphere BE 0.023058 kWh lognormal, GSD² 1.05 — 1.3 ·
xxx Electricity, production mix IE technosphere IE 0.008204 kWh lognormal, GSD² 1.05 — 1.2 ·
xxx Electricity, production mix HU technosphere HU 0.010456 kWh lognormal, GSD² 1.05 — 1.0 ·
xxx Electricity, production mix AT technosphere AT 0.018635 kWh lognormal, GSD² 1.05 — 0.8 ·
xxx Electricity, production mix EE technosphere EE 0.0026724 kWh lognormal, GSD² 1.05 — 0.7 ·
xxx Electricity, production mix BA technosphere BA 0.0035942 kWh lognormal, GSD² 1.05 — 0.6 ·
xxx Electricity, production mix SK technosphere SK 0.0078989 kWh lognormal, GSD² 1.05 — 0.5 ·
xxx Electricity, production mix SI technosphere SI 0.0045647 kWh lognormal, GSD² 1.05 — 0.4 ·
xxx Electricity, production mix HR technosphere HR 0.0034232 kWh lognormal, GSD² 1.05 — 0.4 ·
xxx Electricity, production mix MK technosphere MK 0.0016722 kWh lognormal, GSD² 1.05 — 0.4 ·
xxx Electricity, production mix SE technosphere SE 0.042545 kWh lognormal, GSD² 1.05 — 0.3 ·
Electricity, production mix CH technosphere CH 0.019596 kWh lognormal, GSD² 1.05 — 0.1 ·
xxx Electricity, production mix LU technosphere LU 7.9250e-04 kWh lognormal, GSD² 1.05 — 0.1 ·
xxx Electricity, production mix LT technosphere LT 0.0037319 kWh lognormal, GSD² 1.05 — 0.1 ·
xxx Electricity, production mix NO technosphere NO 0.041478 kWh lognormal, GSD² 1.05 — 0.1 ·
xxx Electricity, production mix LV technosphere LV 0.0014969 kWh lognormal, GSD² 1.05 — 0.1 ·
xxx Electricity, production mix IS technosphere IS 0.0047532 kWh lognormal, GSD² 1.05 — 0.0 ·

Data quality

0 of 32 direct exchanges carry a declared pedigree, 32 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: René Itten (ZHAW); data entry: René Itten (ZHAW); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure unknown
production volume 3766764 GWh
uncertainty adjustments none
validation details Proof reading validation: 22.06.2012; Other validation: Z:\ESU-Docs\Projekte laufend\401 Update Strommix v3.0\EcoSpold[401-electricity-mix-europe-RER-world-GLO-v1.0.xlsx]X-Process;
time period comment Statistics for 2008

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 6.315e-04 6.143e-04 0.001019 1.3
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9.051e-04 7.315e-04 0.001433 1.41
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.4242 0.4124 0.4937 1.09
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.927e-04 2.281e-04 4.519e-04 1.42
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.4254 0.4135 0.4951 1.09
EF-particulate Matter Impact on human health disease incidence 7.111e-09 6.840e-09 9.937e-09 1.22
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.153 0.9799 2.326 1.54
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.01116 0.009528 0.03245 1.87
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.164 0.9963 2.342 1.54
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 2.826e-04 2.691e-04 4.832e-04 1.35
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 3.799e-04 1.634e-04 0.001277 2.86
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.001352 0.001325 0.002126 1.28
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.597e-11 5.134e-11 1.320e-10 1.62
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 9.823e-11 8.053e-11 1.402e-10 1.35
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.442e-10 1.454e-10 2.488e-10 1.32
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.597e-09 2.642e-09 7.033e-09 1.65
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 8.053e-11 7.670e-11 1.349e-10 1.32
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.677e-09 2.739e-09 7.130e-09 1.63
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.4352 0.1527 2.4 4.2
Land use Soil quality index pt (soil quality index) 1.619 1.204 2.722 1.52
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 7.058e-09 6.086e-09 1.597e-08 1.59
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 7.055e-04 6.693e-04 0.001325 1.42
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 8.655 8.259 12.27 1.22
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 8.095e-08 8.817e-08 1.787e-07 1.44
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.07178 -220.9 113.7 —

Climate change 0.4254 kg CO2 eq per kWh. Main contributors: xxx Electricity, production mix DE 23 %; xxx Electricity, production mix GB 14 %; xxx Electricity, production mix IT 11 %; xxx Electricity, production mix PL 10 %; xxx Electricity, production mix ES 9 %; xxx Electricity, production mix GR 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: xxx Electricity, production mix DE 23 %; xxx Electricity, production mix GB 14 %; xxx Electricity, production mix IT 11 %; xxx Electricity, production mix PL 10 %; xxx Electricity, production mix ES 9 %; xxx Electricity, production mix GR 4 %. Most sensitive exchanges (Section 6.3): xxx Electricity, production mix DE [DE] (-1.1 / +1.1 %); xxx Electricity, production mix GB [GB] (-0.7 / +0.7 %); xxx Electricity, production mix IT [IT] (-0.5 / +0.5 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 6.315e-04 0.001066 0.593
Climate change-Biogenic 9.051e-04 9.046e-04 1.001
Climate change-Fossil 0.4242 0.4241 1.000
Climate change-Land use and land use change 2.927e-04 2.927e-04 1.000
Climate change 0.4254 0.4253 1.000
EF-particulate Matter 7.111e-09 7.109e-09 1.000
Ecotoxicity, freshwater_inorganics 1.153 1.195 0.965
Ecotoxicity, freshwater_organics 0.01116 0.01109 1.006
Ecotoxicity, freshwater 1.164 1.206 0.965
Eutrophication marine 2.826e-04 2.824e-04 1.001
Eutrophication, freshwater 3.799e-04 3.799e-04 1.000
Eutrophication, terrestrial 0.001352 0.002191 0.617
Human toxicity, cancer_inorganics 4.597e-11 3.692e-11 1.245
Human toxicity, cancer_organics 9.823e-11 9.822e-11 1.000
Human toxicity, cancer 1.442e-10 1.351e-10 1.067
Human toxicity, non-cancer_inorganics 2.597e-09 2.326e-09 1.116
Human toxicity, non-cancer_organics 8.053e-11 8.073e-11 0.998
Human toxicity, non-cancer 2.677e-09 2.407e-09 1.112
Ionising radiation, human health 0.4352 0.4352 1.000
Land use 1.619 1.343 1.205
Ozone depletion 7.058e-09 7.045e-09 1.002
Photochemical ozone formation - human health 7.055e-04 7.067e-04 0.998
Resource use, fossils 8.655 8.68 0.997
Resource use, minerals and metals 8.095e-08 7.270e-08 1.114
Water use 0.07178 0.08756 0.820
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.4253 kg CO2 eq; Ecological Scarcity
2021 total 732.8 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
xxx Electricity, production mix DE [DE] 0.1726 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -1.1 / +1.1 1.9 (Climate change-Biogenic)
xxx Electricity, production mix GB [GB] 0.106 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.7 / +0.7 1.0 (Acidification)
xxx Electricity, production mix IT [IT] 0.08646 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.5 / +0.5 1.1 (Ecotoxicity, freshwater_organics)
xxx Electricity, production mix PL [PL] 0.03886 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.4 / +0.5 1.2 (Human toxicity, cancer_inorganics)
xxx Electricity, production mix ES [ES] 0.0869 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.4 / +0.5 1.0 (Ecotoxicity, freshwater_organics)
xxx Electricity, production mix GR [GR] 0.01669 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.2 / +0.2 0.6 (Eutrophication, freshwater)
xxx Electricity, production mix NL [NL] 0.02892 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.2 / +0.2 0.3 (Ecotoxicity, freshwater_organics)
xxx Electricity, production mix CZ [CZ] 0.02227 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.2 / +0.2 0.3 (Eutrophication, freshwater)
xxx Electricity, production mix FR [FR] 0.159 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.2 / +0.2 2.4 (Ionising radiation, human health)
xxx Electricity, production mix RO [RO] 0.01702 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.2 (Eutrophication, freshwater)
xxx Electricity, production mix CS [CS] 0.01001 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.3 (Eutrophication, freshwater)
xxx Electricity, production mix BG [BG] 0.01187 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.2 (Eutrophication, freshwater)
xxx Electricity, production mix PT [PT] 0.01288 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.2 (Climate change-Land use and land use change)
xxx Electricity, production mix FI [FI] 0.02171 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.7 (Land use)
xxx Electricity, production mix DK [DK] 0.01019 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.1 (Land use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.4254 kg CO2 eq per kWh (95 % interval 0.4135–0.4951). Dominant contributors: xxx Electricity, production mix DE 23 %; xxx Electricity, production mix GB 14 %; xxx Electricity, production mix IT 11 %; xxx Electricity, production mix PL 10 %; xxx Electricity, production mix ES 9 %; xxx Electricity, production mix GR 4 %. Most sensitive: xxx Electricity, production mix DE [DE] (-1.1 / +1.1 %); xxx Electricity, production mix GB [GB] (-0.7 / +0.7 %); xxx Electricity, production mix IT [IT] (-0.5 / +0.5 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 7.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 16/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 32/32 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.4254 in [0.4135, 0.4951]
time period declared PASS 9999-01/9999-12
geography is a known location code PASS ENTSO-E
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Itten, R., Frischknecht, R. (2012) Life Cycle Inventories of electricity mixes. Project reports. Volume: 401. ESU-services Ltd.. Uster, CH. Type: Separate publication First author: Itten, R. Other authors: Frischknecht, R. Year: 2012 Title of anthology: Project reports Place of publication: Uster, CH Publisher: ESU-services Ltd. Volume No: 401 — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.