Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Generator, for hybrid passenger car [RER], per 1 kg. EF v3.1 climate change 5.845 kg CO2 eq (Monte Carlo 95 % interval 5.051–8.195). Main contributors: Printed wiring board, mixed mounted, unspec., solder mix, at… 42 %; Aluminium, production mix, at plant 26 %; Steel, low-alloyed, at plant 18 %; Neodymium oxide, at plant 4 %; Copper, at regional storage 3 %; Sheet rolling, steel 3 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Generator, for hybrid passenger car |
| Dataset UUID / graph id | 1ae3d114-3bc7-3335-a165-b728069a4b8a / activity:generator_for_hybrid_passenger_car__rer |
| Reference product, unit | Generator, for hybrid passenger car, 1 kg |
| Location | RER — Switzerland |
| Time period | 2014-01/2014-12 |
| Category | transport systems / road |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
The construction of the datasets allows to change key parameters (like mass of the vehicle, mass of the battery, consumption, life times, etc.) in order to cover a wide spectrum of situations . However, it is important to consider that changing one parameter of a vehicle, e.g. its mass, may lead to changes in other parameters, e.g. the consumption. When modifying the default parameters given, attention should be payed to the possible influence which one parameter may have over the other.; UUID: 1ae3d114-3bc7-3335-a165-b728069a4b8a
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 kg of Generator, for hybrid passenger car (RER). All results are given per unit of the reference flow.
This dataset describes the production of a small generator (25kW) and the production effort is included.
undefined
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Printed wiring board, mixed mounted, unspec., solder mix, at plant | technosphere | GLO | 0.023991 | kg | lognormal, GSD² 1.29 | — | 41.7 | ████████ | |
| Aluminium, production mix, at plant | technosphere | RER | 0.31488 | kg | lognormal, GSD² 1.29 | — | 25.8 | █████ | |
| Steel, low-alloyed, at plant | technosphere | RER | 0.47982 | kg | lognormal, GSD² 1.29 | — | 17.6 | ████ | |
| Neodymium oxide, at plant | technosphere | CN | 0.0063576 | kg | lognormal, GSD² 1.29 | — | 4.2 | █ | |
| Copper, at regional storage | technosphere | RER | 0.11995 | kg | lognormal, GSD² 1.29 | — | 3.3 | █ | |
| Sheet rolling, steel | technosphere | RER | 0.44983 | kg | lognormal, GSD² 1.29 | — | 2.9 | █ | |
| Cable, three-conductor cable, at plant | technosphere | GLO | 0.035986 | m | lognormal, GSD² 1.29 | — | 1.8 | · | |
| Polyphenylene sulfide, at plant | technosphere | GLO | 0.020992 | kg | lognormal, GSD² 1.29 | — | 1.6 | · | |
| Wire drawing, copper | technosphere | RER | 0.11995 | kg | lognormal, GSD² 1.29 | — | 0.8 | · | |
| Ferrite, at plant | technosphere | GLO | 0.017273 | kg | lognormal, GSD² 1.29 | — | 0.4 | · | |
| Boron carbide, at plant | technosphere | GLO | 2.9989e-04 | kg | lognormal, GSD² 1.29 | — | 0.1 | · |
0 of 11 direct exchanges carry a declared pedigree, 11 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Annika Messmer (TREEZE); data entry: Annika Messmer (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | Extrapolations |
| sampling procedure | Sampling Procedure |
| production volume | na |
| uncertainty adjustments | |
| validation details | Proof reading validation: 22.02.2018; Other validation: \SRV01\ESU-Docs\Projekte laufend\561 Aktualisierung Umwelt Elektroauto\EcoSpold\Transport[561_transport_hybrid-car_EIv2_v0.9.xlsx]X-Process; |
| time period comment | Time of publications |
None recorded.
Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.05661 | 0.04781 | 0.07933 | 1.3 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.01799 | 0.01043 | 0.04896 | 2.26 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 5.823 | 5.027 | 8.145 | 1.29 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.003908 | 0.0029 | 0.006382 | 1.49 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 5.845 | 5.051 | 8.195 | 1.29 |
| EF-particulate Matter | Impact on human health | disease incidence | 3.247e-07 | 2.951e-07 | 4.909e-07 | 1.3 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 37.84 | 34.07 | 83.05 | 1.63 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 7.905 | 5.568 | 14 | 1.6 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 45.74 | 41.95 | 91.66 | 1.55 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 0.007474 | 0.00625 | 0.01332 | 1.48 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 0.02306 | 0.01323 | 0.1556 | 3.48 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.07143 | 0.05841 | 0.1131 | 1.41 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 8.958e-09 | 8.086e-09 | 2.277e-08 | 1.74 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.935e-09 | 2.419e-09 | 4.994e-09 | 1.45 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.189e-08 | 1.094e-08 | 2.642e-08 | 1.6 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.778e-07 | 5.839e-07 | 1.835e-06 | 1.83 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.581e-08 | 2.458e-08 | 6.387e-08 | 1.63 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 7.136e-07 | 6.185e-07 | 1.883e-06 | 1.8 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 1.732 | 0.5719 | 10.81 | 4.54 |
| Land use | Soil quality index | pt (soil quality index) | 34.19 | 28.41 | 65.45 | 1.54 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 3.130e-07 | 2.247e-07 | 5.879e-07 | 1.64 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.02567 | 0.02245 | 0.0398 | 1.34 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 78.75 | 69.51 | 122.1 | 1.34 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.001985 | 0.001214 | 0.003555 | 1.76 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.7566 | -1874 | 909.3 | — |
Climate change 5.845 kg CO2 eq per kg. Main contributors: Printed wiring board, mixed mounted, unspec., solder mix, at… 42 %; Aluminium, production mix, at plant 26 %; Steel, low-alloyed, at plant 18 %; Neodymium oxide, at plant 4 %; Copper, at regional storage 3 %; Sheet rolling, steel 3 %.
Direct exchanges dominating climate change: Printed wiring board, mixed mounted, unspec., solder mix, at… 42 %; Aluminium, production mix, at plant 26 %; Steel, low-alloyed, at plant 18 %; Neodymium oxide, at plant 4 %; Copper, at regional storage 3 %; Sheet rolling, steel 3 %. Most sensitive exchanges (Section 6.3): Printed wiring board, mixed mounted, unspec., solder mix, at plant [GLO] (-9.2 / +11.9 %); Aluminium, production mix, at plant [RER] (-5.7 / +7.3 %); Steel, low-alloyed, at plant [RER] (-3.9 / +5.0 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 0.05661 | 0.06635 | 0.853 |
| Climate change-Biogenic | 0.01799 | 0.01799 | 1.000 |
| Climate change-Fossil | 5.823 | 5.823 | 1.000 |
| Climate change-Land use and land use change | 0.003908 | 0.003908 | 1.000 |
| Climate change | 5.845 | 5.845 | 1.000 |
| EF-particulate Matter | 3.247e-07 | 3.247e-07 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 37.84 | 39.04 | 0.969 |
| Ecotoxicity, freshwater_organics | 7.905 | 7.826 | 1.010 |
| Ecotoxicity, freshwater | 45.74 | 46.29 | 0.988 |
| Eutrophication marine | 0.007474 | 0.007473 | 1.000 |
| Eutrophication, freshwater | 0.02306 | 0.02306 | 1.000 |
| Eutrophication, terrestrial | 0.07143 | 0.0746 | 0.958 |
| Human toxicity, cancer_inorganics | 8.958e-09 | 8.922e-09 | 1.004 |
| Human toxicity, cancer_organics | 2.935e-09 | 2.935e-09 | 1.000 |
| Human toxicity, cancer | 1.189e-08 | 1.186e-08 | 1.003 |
| Human toxicity, non-cancer_inorganics | 6.778e-07 | 6.751e-07 | 1.004 |
| Human toxicity, non-cancer_organics | 3.581e-08 | 3.581e-08 | 1.000 |
| Human toxicity, non-cancer | 7.136e-07 | 7.109e-07 | 1.004 |
| Ionising radiation, human health | 1.732 | 1.732 | 1.000 |
| Land use | 34.19 | 29.12 | 1.174 |
| Ozone depletion | 3.130e-07 | 3.130e-07 | 1.000 |
| Photochemical ozone formation - human health | 0.02567 | 0.02567 | 1.000 |
| Resource use, fossils | 78.75 | 78.77 | 1.000 |
| Resource use, minerals and metals | 0.001985 | 0.001977 | 1.004 |
| Water use | 0.7566 | 0.8637 | 0.876 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 5.844 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 2.331e+04 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Printed wiring board, mixed mounted, unspec., solder mix, at plant [GLO] | 0.02399 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -9.2 / +11.9 | 25.6 (Resource use, minerals and metals) |
| Aluminium, production mix, at plant [RER] | 0.3149 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -5.7 / +7.3 | 15.0 (Climate change-Land use and land use change) |
| Steel, low-alloyed, at plant [RER] | 0.4798 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -3.9 / +5.0 | 6.1 (EF-particulate Matter) |
| Neodymium oxide, at plant [CN] | 0.006358 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.9 / +1.2 | 1.7 (Ozone depletion) |
| Copper, at regional storage [RER] | 0.12 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.7 / +0.9 | 15.0 (Human toxicity, non-cancer_organics) |
| Sheet rolling, steel [RER] | 0.4498 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.6 / +0.8 | 1.4 (Water use) |
| Cable, three-conductor cable, at plant [GLO] | 0.03599 m | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.4 / +0.5 | 6.7 (Human toxicity, non-cancer_inorganics) |
| Polyphenylene sulfide, at plant [GLO] | 0.02099 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.4 / +0.5 | 24.7 (Ecotoxicity, freshwater_organics) |
| Wire drawing, copper [RER] | 0.12 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.2 / +0.2 | 0.6 (Human toxicity, non-cancer_organics) |
| Ferrite, at plant [GLO] | 0.01727 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.1 / +0.1 | 0.4 (Ecotoxicity, freshwater_organics) |
| Boron carbide, at plant [GLO] | 2.999e-04 kg | ×0.779 / ×1.28 | lognormal, GSD² 1.29 | -0.0 / +0.0 | 0.0 (EF-particulate Matter) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 5.845 kg CO2 eq per kg (95 % interval 5.051–8.195). Dominant contributors: Printed wiring board, mixed mounted, unspec., solder mix, at… 42 %; Aluminium, production mix, at plant 26 %; Steel, low-alloyed, at plant 18 %; Neodymium oxide, at plant 4 %; Copper, at regional storage 3 %; Sheet rolling, steel 3 %. Most sensitive: Printed wiring board, mixed mounted, unspec., solder mix, at plant [GLO] (-9.2 / +11.9 %); Aluminium, production mix, at plant [RER] (-5.7 / +7.3 %); Steel, low-alloyed, at plant [RER] (-3.9 / +5.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 kg |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 3.1e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 22/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 11/11 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 5.845 in [5.051, 8.195] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | RER |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.