Table of Contents

Ventilation system, centralized, average for 6 m3/(h m2) — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, centralized, average for 6 m3/(h m2) [CH], per 1 m2. EF v3.1 climate change 36.08 kg CO2 eq (Monte Carlo 95 % interval 35.21–42.86). Main contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 10 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation system, various components, m2 7 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 7 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 6 %. Status: final control passed.
Item Value
Dataset name Ventilation system, centralized, average for 6 m3/(h m2)
Dataset UUID / graph id 1ce35a9e-be00-390a-a774-97363a5e82cf / activity:ventilation_system_centralized_average_for_6_m3_h_m2__ch
Reference product, unit Ventilation system, centralized, average for 6 m3/(h m2), 1 m2
Location CH
Time period 2014-01/2014-12
Category ventilation / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of a ventilation system for a building with a specific air flow rate of 6 m3/h per m2 heated gross floor area. The reference value of the inventory is 1 m2 heated gross floor area. The inventory is based on average data of 4 office buildings, 3 schools and 3 residential care homes with a total heated gross floor area of 61719 m2 and a total nominal air flow of 302190 m3/h, specific weight of the components: 11.4 kg/m2, including average components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery and a nominal air flow rate of 5'000-20'000 m3/h per unit. No ground heat exchanger is included.; UUID: 1ce35a9e-be00-390a-a774-97363a5e82cf

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Ventilation system, centralized, average for 6 m3/(h m2) (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.

Technology

Typical technology, materials and components used for ventilation systems in commercial and public buildings

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Ventilation duct, steel, zinc coated, s= 0.75mm, at plant technosphere CH 0.22107 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 15.3 ███
Ventilation duct, steel, zinc coated, s= 0.62mm, at plant technosphere CH 0.17137 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 9.6 ██
Ventilation duct, steel, zinc coated, s= 0.87mm, at plant technosphere CH 0.10729 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 8.4 ██
Ventilation system, various components, m2 technosphere CH 1 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 7.5 █
Ventilation duct, steel, zinc coated, s= 1.0mm, at plant technosphere CH 0.0777 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.9 █
Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant technosphere CH 1.3627e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 5.7 █
Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant technosphere CH 1.0180e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 5.1 █
EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant technosphere CH 0.18508 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 5.0 █
Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant technosphere CH 0.11008 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.6 █
Ventilation duct, steel, zinc coated, s= 1.25mm, at plant technosphere CH 0.031515 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.4 █
Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant technosphere CH 0.064892 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.1 █
Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant technosphere CH 1.4877e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.0 █
Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant technosphere CH 0.25631 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.8 █
Ventilation unit 6700 m3/h, w. cross plate heat excanger, at plant technosphere CH 8.1812e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.6 █
Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant technosphere CH 8.0361e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.0 ·
Silencer for ventilator unit 13000 m3/h, modular, at plant technosphere CH 8.6987e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.8 ·
Ventilation unit 13000 m3/h, w. cross plate heat excanger, at plant technosphere CH 2.9517e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.7 ·
Ventilation duct, steel, zinc coated, s= 1.5mm, at plant technosphere CH 0.011719 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.5 ·
Ventilation unit 6700 m3/h, w. rotary heat exchanger, at plant technosphere CH 4.8477e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.4 ·
EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil, at plant technosphere CH 0.037759 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.3 ·
Silencer for ventilator unit 6700 m3/h, modular, at plant, Device technosphere CH 5.6919e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.8 ·
Ventilation duct, PE corrugated tube, DN 75, at plant technosphere RER 0.25599 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.7 ·
Thermal insulation, 100mm, 40kg/m3, alumium cladding, at plant technosphere CH 0.015561 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.7 ·
Ventilation duct, stainless steel, s= 1.0mm, at plant technosphere CH 0.0039743 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.6 ·
Ventilation unit 1800 m3/h, w. cross plate heat excanger, at plant technosphere CH 4.5078e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.6 ·
Ventilation duct, stainless steel, s= 1.25mm, at plant technosphere CH 0.0029621 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.5 ·
Ventilation duct, stainless steel, s= 1.5mm, at plant technosphere CH 0.0021893 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.5 ·
Ventilator unit 13000 m3/h, modular, w. filter, without silencer, at plant technosphere CH 3.3775e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.4 ·
Thermal insulation, 30mm, 40kg/m3, stainless steel cladding, at plant technosphere CH 0.0040284 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.4 ·
Silencer for ventilator unit 3500 m3/h, modular, at plant technosphere CH 3.2614e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.3 ·
Thermal insulation, 60mm, 40kg/m3, reinforced alumium foil, at plant technosphere CH 0.016036 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Ventilator unit 3500 m3/h, modular, w. filter, without silencer, at plant technosphere CH 5.0939e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.2 ·
Ventilation unit 3500 m3/h, w. circuit connected heat exchanger, at plant technosphere CH 1.3690e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.2 ·
Ventilation duct, stainless steel, s= 0.87mm, at plant technosphere CH 0.0015128 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Thermal insulation, 60mm, 40kg/m3, stainless steel cladding, at plant technosphere CH 0.0018308 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Spiral-seam duct, steel, zinc coated, s= 0.8mm, at plant technosphere CH 0.002751 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.2 ·
Silencer for ventilator unit 1800 m3/h, modular, at plant, Device technosphere CH 1.4278e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.1 ·
Flexible duct, aluminum/PET, DN of 125, at plant technosphere RER 0.043789 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Ventilation equipment, central, 600-1200 m3/h, at plant technosphere RER 5.7278e-05 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.1 ·
Thermal insulation, 100mm, 40kg/m3, reinforced alumium foil, at plant technosphere CH 0.004904 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Ventilation duct, stainless steel, s= 0.62mm, at plant technosphere CH 0.0010338 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Spiral-seam duct, stainless steel, s= 0.8mm, at plant technosphere CH 6.4780e-04 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Ventilation duct, stainless steel, s= 0.75mm, at plant technosphere CH 2.0238e-04 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Spiral-seam duct, stainless steel, s= 0.5mm, at plant technosphere CH 2.4473e-04 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Spiral-seam duct, steel, zinc coated, s= 1.0mm, at plant technosphere CH 4.8320e-05 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·

Data quality

45 of 45 direct exchanges carry a declared pedigree, 45 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.36 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Data from different call of bids for ventilation system used. Data completed with information from literature and from manufacturers
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Process information partly from 2003 to 2012

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.5086 0.3356 0.9499 1.74
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1302 0.09077 0.2787 1.76
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 35.94 35.08 42.69 1.11
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01804 0.01474 0.02998 1.44
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 36.08 35.21 42.86 1.11
EF-particulate Matter Impact on human health disease incidence 5.548e-06 4.157e-06 9.289e-06 1.5
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 164.8 163.4 283.3 1.33
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 3.892 3.599 7.934 1.66
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 168.7 167.6 288.8 1.33
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.03972 0.03553 0.05803 1.28
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.02014 0.01491 0.0882 2.5
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1.992 1.201 3.936 1.88
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.988e-08 1.981e-08 4.599e-08 1.54
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.582e-08 1.372e-08 2.875e-08 1.44
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.570e-08 3.651e-08 6.799e-08 1.37
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.408e-06 1.269e-06 3.683e-06 1.71
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.187e-08 3.762e-08 1.026e-07 1.67
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.460e-06 1.315e-06 3.771e-06 1.69
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 9.586 3.548 59.08 4.28
Land use Soil quality index pt (soil quality index) 181.1 176.2 294.8 1.29
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 9.856e-07 8.749e-07 1.593e-06 1.35
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.1078 0.1026 0.1672 1.29
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 427.4 406.5 587.7 1.2
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 8.058e-04 -8.406e-04 0.003854 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 4.561 -8227 4052 —

Climate change 36.08 kg CO2 eq per m2. Main contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 10 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation system, various components, m2 7 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 7 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 6 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 10 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation system, various components, m2 7 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 7 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 6 %. Most sensitive exchanges (Section 6.3): Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.9 / +3.6 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-1.8 / +2.3 %); Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] (-1.6 / +2.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.5086 0.5326 0.955
Climate change-Biogenic 0.1302 0.1302 1.000
Climate change-Fossil 35.94 35.94 1.000
Climate change-Land use and land use change 0.01804 0.01804 1.000
Climate change 36.08 36.08 1.000
EF-particulate Matter 5.548e-06 5.548e-06 1.000
Ecotoxicity, freshwater_inorganics 164.8 165.9 0.994
Ecotoxicity, freshwater_organics 3.892 3.737 1.041
Ecotoxicity, freshwater 168.7 169.4 0.996
Eutrophication marine 0.03972 0.03972 1.000
Eutrophication, freshwater 0.02014 0.02014 1.000
Eutrophication, terrestrial 1.992 1.999 0.997
Human toxicity, cancer_inorganics 1.988e-08 1.975e-08 1.006
Human toxicity, cancer_organics 1.582e-08 1.582e-08 1.000
Human toxicity, cancer 3.570e-08 3.557e-08 1.004
Human toxicity, non-cancer_inorganics 1.408e-06 1.403e-06 1.003
Human toxicity, non-cancer_organics 5.187e-08 5.186e-08 1.000
Human toxicity, non-cancer 1.460e-06 1.455e-06 1.003
Ionising radiation, human health 9.586 9.586 1.000
Land use 181.1 152.1 1.191
Ozone depletion 9.856e-07 9.856e-07 1.000
Photochemical ozone formation - human health 0.1078 0.1078 1.000
Resource use, fossils 427.4 427.6 1.000
Resource use, minerals and metals 8.058e-04 7.921e-04 1.017
Water use 4.561 4.922 0.927
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 36.08 kg CO2 eq; Ecological Scarcity
2021 total 8.779e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] 0.2211 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -2.9 / +3.6 5.2 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] 0.1714 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.8 / +2.3 4.0 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] 0.1073 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.6 / +2.0 2.6 (Eutrophication, terrestrial)
Ventilation system, various components, m2 [CH] 1 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.4 / +1.7 2.0 (Climate change-Biogenic)
Ventilation duct, steel, zinc coated, s= 1.0mm, at plant [CH] 0.0777 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.3 / +1.6 1.9 (Eutrophication, terrestrial)
Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant [CH] 1.363e-04 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.2 / +1.4 4.4 (Eutrophication, freshwater)
Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant [CH] 1.018e-04 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.0 / +1.3 2.4 (Resource use, minerals and metals)
EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant [CH] 0.1851 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.0 / +1.2 4.5 (Ecotoxicity, freshwater_organics)
Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant [CH] 0.1101 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.9 / +1.1 2.2 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 1.25mm, at plant [CH] 0.03152 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.8 0.9 (Climate change-Land use and land use change)
Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant [CH] 1.488e-04 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.6 / +0.8 1.0 (Eutrophication, freshwater)
Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant [CH] 0.06489 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.7 1.3 (Eutrophication, terrestrial)
Ventilation unit 6700 m3/h, w. cross plate heat excanger, at plant [CH] 8.181e-05 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.5 / +0.7 1.1 (Eutrophication, freshwater)
Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant [CH] 0.2563 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.5 / +0.7 1.6 (Ecotoxicity, freshwater_organics)
Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant [CH] 8.036e-05 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.4 / +0.5 1.4 (Eutrophication, freshwater)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 36.08 kg CO2 eq per m2 (95 % interval 35.21–42.86). Dominant contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 15 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 10 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation system, various components, m2 7 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 7 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 6 %. Most sensitive: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.9 / +3.6 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-1.8 / +2.3 %); Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] (-1.6 / +2.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 5.8e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 45/45 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 36.08 in [35.21, 42.86]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.