Table of Contents

Electricity mix — NL

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity mix [NL], per 1 kWh. EF v3.1 climate change 0.2705 kg CO2 eq (Monte Carlo 95 % interval 0.2121–0.458). Main contributors: Electricity, from natural gas 52 %; Electricity, hard coal, at power plant 22 %; Electricity imports 13 %; Electricity, industrial gas, at power plant 5 %; Electricity, at cogen 300kWth, diesel, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 2 %. Status: final control passed.
Item Value
Dataset name Electricity mix
Dataset UUID / graph id 1e1ab8a9-4ce8-351d-9a2f-ddc2fcb05d03 / activity:electricity_mix__nl
Reference product, unit Electricity mix, 1 kWh
Location NL — Data apply to utilities and auto-producers.
Time period 2023/2023
Category electricity / supply mix
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Electricity domestic net production and import shares are based on annual averages for the years 2021-2023. Only gross to net electicity conversion losses are included as the power plants could not be operated without these, whereas other losses (such as transmission and distribution losses) are not included. Electricity trade between countries is included. UUID: 1e1ab8a9-4ce8-351d-9a2f-ddc2fcb05d03

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity mix (NL). All results are given per unit of the reference flow.

System boundary

Included are the shares of corresponding electricity production by technology and country at the busbar. Not included are transformation, transport or distribution losses.

Technology

No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, from natural gas technosphere NL 0.31613 kWh lognormal, GSD² 1.05 — 52.3 ██████████
Electricity, hard coal, at power plant technosphere NL 0.06379 kWh lognormal, GSD² 1.05 — 22.4 ████
Electricity imports technosphere NL 0.15297 kWh lognormal, GSD² 1.07 — 13.2 ███
Electricity, industrial gas, at power plant technosphere NL 0.010015 kWh lognormal, GSD² 1.05 — 5.3 █
Electricity, at cogen 300kWth, diesel, allocation exergy technosphere CH 0.0106 kWh lognormal, GSD² 1.11 — 2.9 █
Electricity, production mix photovoltaic, at plant technosphere NL 0.13479 kWh lognormal, GSD² 1.05 — 1.5 ·
Electricity, at wind farm technosphere RER 0.21329 kWh lognormal, GSD² 1.05 — 1.1 ·
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.037052 kWh lognormal, GSD² 1.11 — 0.9 ·
Electricity, at cogen with biogas engine, allocation exergy technosphere CH 0.0051474 kWh lognormal, GSD² 1.11 — 0.3 ·
Electricity, nuclear, at power plant pressure water reactor technosphere DE 0.027452 kWh lognormal, GSD² 1.11 — 0.1 ·
Electricity, oil, at power plant technosphere NL 1.3888e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 4.9262e-04 kWh lognormal, GSD² 1.05 — 0.0 ·
Electricity from waste, at municipal waste incineration plant technosphere CH 0.028141 kWh lognormal, GSD² 1.11 — -0.0 ·

Data quality

0 of 13 direct exchanges carry a declared pedigree, 13 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Christopher Oberschelp (ETH); data entry: Christopher Oberschelp (ETH); validation (proof reading): René Itten (ZHAW)
sampling procedure Statistical data
uncertainty adjustments none
validation details manual review of spold files and documentation
time period comment Time period of statistics used.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 3.172e-04 2.795e-04 6.677e-04 1.57
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.001908 0.001265 0.00407 1.8
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2685 0.2106 0.456 1.48
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.997e-05 3.149e-05 9.966e-05 1.81
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2705 0.2121 0.458 1.48
EF-particulate Matter Impact on human health disease incidence 2.976e-09 2.641e-09 6.250e-09 1.58
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.7042 0.3944 3.094 2.99
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.01477 0.008169 0.07098 3.06
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.719 0.4027 3.145 2.99
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 1.336e-04 1.131e-04 2.897e-04 1.63
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 7.660e-05 4.615e-05 2.601e-04 2.46
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.001239 0.001053 0.002545 1.59
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.210e-11 1.407e-11 4.439e-11 1.77
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.313e-10 1.647e-10 3.692e-10 1.52
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.434e-10 1.848e-10 3.963e-10 1.48
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 8.382e-10 9.153e-10 2.841e-09 1.79
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.473e-11 5.305e-11 1.720e-10 1.85
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 9.030e-10 9.779e-10 2.974e-09 1.78
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.07445 0.02276 0.5191 4.87
Land use Soil quality index pt (soil quality index) 4.136 2.907 6.974 1.55
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 7.168e-09 3.483e-09 2.958e-08 3.01
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 4.522e-04 3.520e-04 0.001249 1.93
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 4.2 2.41 13.96 2.53
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 4.109e-07 3.834e-07 8.607e-07 1.49
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.0168 -27.67 15.16 —

Climate change 0.2705 kg CO2 eq per kWh. Main contributors: Electricity, from natural gas 52 %; Electricity, hard coal, at power plant 22 %; Electricity imports 13 %; Electricity, industrial gas, at power plant 5 %; Electricity, at cogen 300kWth, diesel, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, from natural gas 52 %; Electricity, hard coal, at power plant 22 %; Electricity imports 13 %; Electricity, industrial gas, at power plant 5 %; Electricity, at cogen 300kWth, diesel, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 2 %. Most sensitive exchanges (Section 6.3): Electricity, from natural gas [NL] (-2.4 / +2.6 %); Electricity, hard coal, at power plant [NL] (-1.0 / +1.1 %); Electricity imports [NL] (-0.9 / +0.9 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 3.172e-04 3.701e-04 0.857
Climate change-Biogenic 0.001908 0.001908 1.000
Climate change-Fossil 0.2685 0.2685 1.000
Climate change-Land use and land use change 3.997e-05 3.997e-05 1.000
Climate change 0.2705 0.2705 1.000
EF-particulate Matter 2.976e-09 2.976e-09 1.000
Ecotoxicity, freshwater_inorganics 0.7042 0.7147 0.985
Ecotoxicity, freshwater_organics 0.01477 0.01457 1.013
Ecotoxicity, freshwater 0.719 0.729 0.986
Eutrophication marine 1.336e-04 1.336e-04 1.000
Eutrophication, freshwater 7.660e-05 7.660e-05 1.000
Eutrophication, terrestrial 0.001239 0.001402 0.884
Human toxicity, cancer_inorganics 1.210e-11 1.157e-11 1.045
Human toxicity, cancer_organics 2.313e-10 2.313e-10 1.000
Human toxicity, cancer 2.434e-10 2.429e-10 1.002
Human toxicity, non-cancer_inorganics 8.382e-10 8.156e-10 1.028
Human toxicity, non-cancer_organics 6.473e-11 6.472e-11 1.000
Human toxicity, non-cancer 9.030e-10 8.803e-10 1.026
Ionising radiation, human health 0.07445 0.07445 1.000
Land use 4.136 3.474 1.191
Ozone depletion 7.168e-09 7.168e-09 1.000
Photochemical ozone formation - human health 4.522e-04 4.522e-04 1.000
Resource use, fossils 4.2 4.2 1.000
Resource use, minerals and metals 4.109e-07 3.909e-07 1.051
Water use 0.0168 0.02285 0.735
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2704 kg CO2 eq; Ecological Scarcity
2021 total 384.9 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, from natural gas [NL] 0.3161 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -2.4 / +2.6 3.3 (Ozone depletion)
Electricity, hard coal, at power plant [NL] 0.06379 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -1.0 / +1.1 2.2 (Eutrophication, freshwater)
Electricity imports [NL] 0.153 kWh ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.9 / +0.9 4.5 (Climate change-Biogenic)
Electricity, at cogen 300kWth, diesel, allocation exergy [CH] 0.0106 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.3 / +0.3 6.4 (Human toxicity, cancer_organics)
Electricity, industrial gas, at power plant [NL] 0.01001 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.2 / +0.3 0.3 (Climate change-Fossil)
Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] 0.03705 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.1 / +0.1 7.9 (Land use)
Electricity, production mix photovoltaic, at plant [NL] 0.1348 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 3.0 (Resource use, minerals and metals)
Electricity, at wind farm [RER] 0.2133 kWh ×0.952 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 0.9 (Human toxicity, cancer_inorganics)
Electricity, at cogen with biogas engine, allocation exergy [CH] 0.005147 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.0 / +0.0 2.9 (Climate change-Biogenic)
Electricity, nuclear, at power plant pressure water reactor [DE] 0.02745 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 -0.0 / +0.0 4.9 (Ionising radiation, human health)
Electricity, oil, at power plant [NL] 1.389e-04 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.0 (Photochemical ozone formation - human health)
Electricity, hydropower, at run-of-river power plant [RER] 4.926e-04 kWh ×0.952 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.0 (Climate change-Biogenic)
Electricity from waste, at municipal waste incineration plant [CH] 0.02814 kWh ×0.9 / ×1.11 lognormal, GSD² 1.11 +0.0 / -0.0 0.0 (Human toxicity, non-cancer)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

Source Scope Value This dataset Ratio Note
bafu Electricity mix [ET] 0.006645 kg CO2 eq 0.2705 40.70 same dataset name, other location
bafu Electricity mix [IS] 0.02727 kg CO2 eq 0.2705 9.92 same dataset name, other location
bafu Electricity mix [SE] 0.03344 kg CO2 eq 0.2705 8.09 same dataset name, other location
bafu Electricity mix [NO] 0.04653 kg CO2 eq 0.2705 5.81 same dataset name, other location
bafu Electricity mix [FR] 0.0644 kg CO2 eq 0.2705 4.20 same dataset name, other location
bafu Electricity mix [GLO] 0.5483 kg CO2 eq 0.2705 0.49 same dataset name, other location
bafu Electricity mix [BA] 0.8037 kg CO2 eq 0.2705 0.34 same dataset name, other location
bafu Electricity mix [KZ] 0.8184 kg CO2 eq 0.2705 0.33 same dataset name, other location
bafu Electricity mix [ID] 0.8232 kg CO2 eq 0.2705 0.33 same dataset name, other location
bafu Electricity mix [IN] 0.9109 kg CO2 eq 0.2705 0.30 same dataset name, other location
bafu Electricity mix [ZA] 0.9667 kg CO2 eq 0.2705 0.28 same dataset name, other location

Conclusions and limitations

GWP100 0.2705 kg CO2 eq per kWh (95 % interval 0.2121–0.458). Dominant contributors: Electricity, from natural gas 52 %; Electricity, hard coal, at power plant 22 %; Electricity imports 13 %; Electricity, industrial gas, at power plant 5 %; Electricity, at cogen 300kWth, diesel, allocation exergy 3 %; Electricity, production mix photovoltaic, at plant 2 %. Most sensitive: Electricity, from natural gas [NL] (-2.4 / +2.6 %); Electricity, hard coal, at power plant [NL] (-1.0 / +1.1 %); Electricity imports [NL] (-0.9 / +0.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1; categories within ±5 %: 20/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 13/13 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.2705 in [0.2121, 0.458]
time period declared PASS 2023/2023
geography is a known location code PASS NL
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Oberschelp C. (2025) 2025 - Electricity mixes in UVEK database - Oberschelp. Oberschelp Consulting — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.