Table of Contents

Tower server, at data center — GLO

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Tower server, at data center [GLO], per 1 p. EF v3.1 climate change 482.9 kg CO2 eq (Monte Carlo 95 % interval 442–671.1). Main contributors: Printed wiring board, mounted, Desktop PC mainboard, at plan… 42 %; Chassis, network main devices, at plant 32 %; Printed wiring board, power supply unit desktop PC, Pb free,… 9 %; Integrated circuit, IC, memory type, at plant 6 %; CPU, network equipment, at plant 5 %; HDD, desktop computer, at plant 5 %. Status: final control passed.
Item Value
Dataset name Tower server, at data center
Dataset UUID / graph id 2de839ed-bb09-3ac8-942c-264aa5a5075c / activity:tower_server_at_data_center__glo
Reference product, unit Tower server, at data center, 1 p
Location GLO — Typical tower servers.
Time period 2023-01/2029-12
Category electronics / internet network
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The tower server contains various electronic components and hardware; UUID: 2de839ed-bb09-3ac8-942c-264aa5a5075c

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Tower server, at data center (GLO). All results are given per unit of the reference flow.

System boundary

The dataset is based on one tower server (i.e., HP ProLiant ML350p Gen8). Generally, public information on tower servers are quite limited when compared to other server types (rack, blade). Nevertheless, the model is built on the inventory modeling concepts and assumptions borrowed from other server types.

Technology

Tower servers used in the data centers.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Printed wiring board, mounted, Desktop PC mainboard, at plant technosphere GLO 1.8 kg lognormal, GSD² 1.27 — 41.8 ████████
Chassis, network main devices, at plant technosphere GLO 35 kg lognormal, GSD² 1.27 — 32.5 ██████
Printed wiring board, power supply unit desktop PC, Pb free, at plant technosphere GLO 1.36 kg lognormal, GSD² 1.27 — 8.8 ██
Integrated circuit, IC, memory type, at plant technosphere GLO 0.08 kg lognormal, GSD² 1.27 — 5.8 █
CPU, network equipment, at plant technosphere GLO 0.43 kg lognormal, GSD² 1.27 — 5.1 █
HDD, desktop computer, at plant technosphere GLO 5 p lognormal, GSD² 1.27 — 4.8 █
Cable, network cable, category 5, without plugs, at plant technosphere GLO 7.22 m lognormal, GSD² 1.27 — 0.6 ·
Fan, at plant technosphere GLO 0.3 kg lognormal, GSD² 1.27 — 0.6 ·

Data quality

0 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH)
extrapolations Average technology
sampling procedure Literature & own estimations
production volume unknown
uncertainty adjustments none
validation details Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 5.575 4.03 9.521 1.55
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.906 1.093 5.284 2.18
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 480.7 439.7 668.4 1.25
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.3211 0.2608 0.5284 1.44
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 482.9 442 671.1 1.25
EF-particulate Matter Impact on human health disease incidence 2.521e-05 2.302e-05 4.112e-05 1.34
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 4200 3936 9766 1.62
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 86.75 80.34 146.6 1.42
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 4287 4036 9901 1.61
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.7354 0.6367 1.389 1.51
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 2.756 1.628 19.26 3.47
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 7.181 5.925 11.44 1.42
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 9.366e-07 7.414e-07 2.917e-06 2.03
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.585e-07 1.391e-07 2.621e-07 1.39
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.095e-06 9.100e-07 3.119e-06 1.88
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 8.103e-05 5.577e-05 2.720e-04 2.28
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.211e-06 1.616e-06 7.688e-06 2.22
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 8.424e-05 5.869e-05 2.751e-04 2.24
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 106.1 37.4 721 4.71
Land use Soil quality index pt (soil quality index) 4324 3596 7690 1.48
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 3.311e-05 2.643e-05 5.423e-05 1.45
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 2.513 2.273 3.858 1.32
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 6272 5801 9667 1.3
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.2857 0.221 0.4204 1.39
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 67.6 -1.647e+05 8.446e+04 —

Climate change 482.9 kg CO2 eq per p. Main contributors: Printed wiring board, mounted, Desktop PC mainboard, at plan… 42 %; Chassis, network main devices, at plant 32 %; Printed wiring board, power supply unit desktop PC, Pb free,… 9 %; Integrated circuit, IC, memory type, at plant 6 %; CPU, network equipment, at plant 5 %; HDD, desktop computer, at plant 5 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Printed wiring board, mounted, Desktop PC mainboard, at plan… 42 %; Chassis, network main devices, at plant 32 %; Printed wiring board, power supply unit desktop PC, Pb free,… 9 %; Integrated circuit, IC, memory type, at plant 6 %; CPU, network equipment, at plant 5 %; HDD, desktop computer, at plant 5 %. Most sensitive exchanges (Section 6.3): Printed wiring board, mounted, Desktop PC mainboard, at plant [GLO] (-8.7 / +11.0 %); Chassis, network main devices, at plant [GLO] (-6.8 / +8.6 %); Printed wiring board, power supply unit desktop PC, Pb free, at plant [GLO] (-1.8 / +2.3 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 5.575 6.435 0.866
Climate change-Biogenic 1.906 1.906 1.000
Climate change-Fossil 480.7 480.7 1.000
Climate change-Land use and land use change 0.3211 0.3211 1.000
Climate change 482.9 482.9 1.000
EF-particulate Matter 2.521e-05 2.521e-05 1.000
Ecotoxicity, freshwater_inorganics 4200 4394 0.956
Ecotoxicity, freshwater_organics 86.75 73.42 1.182
Ecotoxicity, freshwater 4287 4381 0.978
Eutrophication marine 0.7354 0.7354 1.000
Eutrophication, freshwater 2.756 2.756 1.000
Eutrophication, terrestrial 7.181 7.483 0.960
Human toxicity, cancer_inorganics 9.366e-07 9.326e-07 1.004
Human toxicity, cancer_organics 1.585e-07 1.585e-07 1.000
Human toxicity, cancer 1.095e-06 1.091e-06 1.004
Human toxicity, non-cancer_inorganics 8.103e-05 8.069e-05 1.004
Human toxicity, non-cancer_organics 3.211e-06 3.211e-06 1.000
Human toxicity, non-cancer 8.424e-05 8.391e-05 1.004
Ionising radiation, human health 106.1 106.1 1.000
Land use 4324 3730 1.159
Ozone depletion 3.311e-05 3.311e-05 1.000
Photochemical ozone formation - human health 2.513 2.513 1.000
Resource use, fossils 6272 6274 1.000
Resource use, minerals and metals 0.2857 0.2853 1.001
Water use 67.6 77.44 0.873
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 482.8 kg CO2 eq; Ecological Scarcity
2021 total 2.440e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Printed wiring board, mounted, Desktop PC mainboard, at plant [GLO] 1.8 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -8.7 / +11.0 16.4 (Resource use, minerals and metals)
Chassis, network main devices, at plant [GLO] 35 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -6.8 / +8.6 19.9 (Human toxicity, non-cancer_organics)
Printed wiring board, power supply unit desktop PC, Pb free, at plant [GLO] 1.36 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -1.8 / +2.3 3.5 (Ecotoxicity, freshwater_organics)
Integrated circuit, IC, memory type, at plant [GLO] 0.08 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -1.2 / +1.5 4.1 (Ozone depletion)
CPU, network equipment, at plant [GLO] 0.43 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -1.1 / +1.3 3.7 (Resource use, minerals and metals)
HDD, desktop computer, at plant [GLO] 5 p ×0.791 / ×1.26 lognormal, GSD² 1.27 -1.0 / +1.3 1.7 (Ionising radiation, human health)
Cable, network cable, category 5, without plugs, at plant [GLO] 7.22 m ×0.791 / ×1.26 lognormal, GSD² 1.27 -0.1 / +0.2 0.6 (Human toxicity, non-cancer_organics)
Fan, at plant [GLO] 0.3 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -0.1 / +0.2 0.2 (Ecotoxicity, freshwater_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 482.9 kg CO2 eq per p (95 % interval 442–671.1). Dominant contributors: Printed wiring board, mounted, Desktop PC mainboard, at plan… 42 %; Chassis, network main devices, at plant 32 %; Printed wiring board, power supply unit desktop PC, Pb free,… 9 %; Integrated circuit, IC, memory type, at plant 6 %; CPU, network equipment, at plant 5 %; HDD, desktop computer, at plant 5 %. Most sensitive: Printed wiring board, mounted, Desktop PC mainboard, at plant [GLO] (-8.7 / +11.0 %); Chassis, network main devices, at plant [GLO] (-6.8 / +8.6 %); Printed wiring board, power supply unit desktop PC, Pb free, at plant [GLO] (-1.8 / +2.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.2e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 482.9 in [442, 671.1]
time period declared PASS 2023-01/2029-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.