Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset 570 kWp open ground installation, CdTe, on open ground [RER], per 1 p. EF v3.1 climate change 3.470e+05 kg CO2 eq (Monte Carlo 95 % interval 2.167e+05–9.921e+05). Main contributors: Photovoltaic laminate, CdTe, mix, at regional storage 50 %; Open ground construction, on ground 35 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 4 %; Electric installation, 570 kWp photovoltaic plant, at plant 2 %; Transport, freight, lorry, 7.5t-16t gross weight, fleet aver… 1 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | 570 kWp open ground installation, CdTe, on open ground |
| Dataset UUID / graph id | 3b46feb5-bda8-394a-af31-8cb2c54b2ded / activity:570_kwp_open_ground_installation_cdte_on_open_ground__rer |
| Reference product, unit | 570 kWp open ground installation, CdTe, on open ground, 1 p |
| Location | RER — Installation in Europe. |
| Time period | 2014-01/2018-12 |
| Category | chemicals / processing |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Photovoltaic installation with a capacity of 570kWp and a life time of 30 years installed in Europe. The efficiency of CdTe PV modules is 16.8% (average of First Solar Series 4 and Series 6 modules in 2018). The share of rejected or replaced PV modules is 1% based on company information. The inverter is assumed to be replaced once during the service life of the PV system.; UUID: 3b46feb5-bda8-394a-af31-8cb2c54b2ded
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Reference flow: 1 p of 570 kWp open ground installation, CdTe, on open ground (RER). All results are given per unit of the reference flow.
All components for the installation of a 570kWp photovoltaic plant, energy use for the mounting, transport of materials and persons to the construction place. Disposal of components after end of life.
Current technology for mounting of panels or laminates, electric installations and other components.
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Photovoltaic laminate, CdTe, mix, at regional storage | technosphere | RER | 3198.3 | m2 | lognormal, GSD² 3.02 | — | 49.6 | ██████████ | |
| Open ground construction, on ground | technosphere | RER | 3166.7 | m2 | lognormal, GSD² 3 | — | 35.2 | ███████ | |
| Inverter, 500kW, at plant | technosphere | RER | 2.28 | p | lognormal, GSD² 3 | — | 8.1 | ██ | |
| Treatment, c-Si PV module | technosphere | RER | 51205 | kg | lognormal, GSD² 1.3 | — | 4.1 | █ | |
| Electric installation, 570 kWp photovoltaic plant, at plant | technosphere | ES | 1 | p | lognormal, GSD² 3 | — | 1.7 | · | |
| Transport, freight, lorry, 7.5t-16t gross weight, fleet average | technosphere | RER | 9387.6 | tkm | lognormal, GSD² 2.1 | — | 1.2 | · | |
| Diesel, burned in building machine, average | technosphere | CH | 7673.1 | MJ | lognormal, GSD² 2 | — | 0.2 | · | |
| Electricity, low voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 36.033 | kWh | lognormal, GSD² 1.07 | — | 0.0 | · | |
| Waste Heat | elementary | air/Ground level / Urban (>1000 people/s… | 129.72 | MJ | lognormal, GSD² 1.07 | — | 0.0 | · |
0 of 9 direct exchanges carry a declared pedigree, 9 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | Estimations for lifetime of PV modules (30a) and inverters (15a) as well as for transport distances. |
| sampling procedure | Publication for efficiency, mounting systems and own estimations for other components. |
| production volume | Total installed capacity in 2018: 120 GWp in Europe. |
| uncertainty adjustments | |
| validation details | Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process; |
| time period comment | Average module efficiency in 2018. |
None recorded.
Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 1864 | 1175 | 5534 | 2.23 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 951.4 | 446.8 | 3738 | 3.13 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 3.458e+05 | 2.156e+05 | 9.848e+05 | 2.23 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 324.8 | 208.2 | 875.5 | 2.08 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 3.470e+05 | 2.167e+05 | 9.921e+05 | 2.23 |
| EF-particulate Matter | Impact on human health | disease incidence | 0.01677 | 0.01072 | 0.1522 | 3.76 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.450e+06 | 9.537e+05 | 5.727e+06 | 2.56 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 4.504e+04 | 3.149e+04 | 1.716e+05 | 2.39 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.495e+06 | 9.847e+05 | 5.857e+06 | 2.55 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 388.8 | 246.6 | 1236 | 2.36 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 166.3 | 109.8 | 1083 | 3.26 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 4264 | 2628 | 1.37e+04 | 2.35 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.620e-04 | 1.139e-04 | 7.727e-04 | 2.67 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 7.191e-05 | 4.690e-05 | 2.401e-04 | 2.28 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 2.339e-04 | 1.661e-04 | 9.711e-04 | 2.45 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 0.008087 | 0.006496 | 0.03481 | 2.32 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 4.271e-04 | 2.664e-04 | 0.001249 | 2.15 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 0.008515 | 0.00685 | 0.0358 | 2.29 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 8.178e+04 | 2.491e+04 | 6.025e+05 | 5.27 |
| Land use | Soil quality index | pt (soil quality index) | 1.443e+08 | 5.262e+07 | 4.604e+08 | 3.13 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 0.007558 | 0.005074 | 0.02512 | 2.28 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 1236 | 817.6 | 3753 | 2.26 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 4.485e+06 | 2.829e+06 | 1.399e+07 | 2.31 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 16 | 6.234 | 79.12 | 3.63 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 3.711e+04 | -9.672e+07 | 5.380e+07 | — |
Climate change 3.470e+05 kg CO2 eq per p. Main contributors: Photovoltaic laminate, CdTe, mix, at regional storage 50 %; Open ground construction, on ground 35 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 4 %; Electric installation, 570 kWp photovoltaic plant, at plant 2 %; Transport, freight, lorry, 7.5t-16t gross weight, fleet aver… 1 %.
Direct exchanges dominating climate change: Photovoltaic laminate, CdTe, mix, at regional storage 50 %; Open ground construction, on ground 35 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 4 %; Electric installation, 570 kWp photovoltaic plant, at plant 2 %; Transport, freight, lorry, 7.5t-16t gross weight, fleet aver… 1 %. Most sensitive exchanges (Section 6.3): Photovoltaic laminate, CdTe, mix, at regional storage [RER] (-32.8 / +96.8 %); Open ground construction, on ground [RER] (-23.2 / +68.2 %); Inverter, 500kW, at plant [RER] (-5.3 / +15.6 %).
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 1864 | 1945 | 0.958 |
| Climate change-Biogenic | 951.4 | 951.4 | 1.000 |
| Climate change-Fossil | 3.458e+05 | 3.458e+05 | 1.000 |
| Climate change-Land use and land use change | 324.8 | 324.8 | 1.000 |
| Climate change | 3.470e+05 | 3.470e+05 | 1.000 |
| EF-particulate Matter | 0.01677 | 0.01677 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 1.450e+06 | 1.494e+06 | 0.970 |
| Ecotoxicity, freshwater_organics | 4.504e+04 | 4.164e+04 | 1.082 |
| Ecotoxicity, freshwater | 1.495e+06 | 1.535e+06 | 0.974 |
| Eutrophication marine | 388.8 | 388.8 | 1.000 |
| Eutrophication, freshwater | 166.3 | 166.3 | 1.000 |
| Eutrophication, terrestrial | 4264 | 4380 | 0.973 |
| Human toxicity, cancer_inorganics | 1.620e-04 | 1.613e-04 | 1.005 |
| Human toxicity, cancer_organics | 7.191e-05 | 7.191e-05 | 1.000 |
| Human toxicity, cancer | 2.339e-04 | 2.332e-04 | 1.003 |
| Human toxicity, non-cancer_inorganics | 0.008087 | 0.008057 | 1.004 |
| Human toxicity, non-cancer_organics | 4.271e-04 | 4.270e-04 | 1.000 |
| Human toxicity, non-cancer | 0.008515 | 0.008484 | 1.004 |
| Ionising radiation, human health | 8.178e+04 | 8.178e+04 | 1.000 |
| Land use | 1.443e+08 | 1.439e+08 | 1.002 |
| Ozone depletion | 0.007558 | 0.007558 | 1.000 |
| Photochemical ozone formation - human health | 1236 | 1236 | 1.000 |
| Resource use, fossils | 4.485e+06 | 4.486e+06 | 1.000 |
| Resource use, minerals and metals | 16 | 15.82 | 1.011 |
| Water use | 3.711e+04 | 3.967e+04 | 0.935 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 3.469e+05 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 9.354e+08 UBP. |
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Photovoltaic laminate, CdTe, mix, at regional storage [RER] | 3198 m2 | ×0.339 / ×2.95 | lognormal, GSD² 3.02 | -32.8 / +96.8 | 157.4 (Resource use, minerals and metals) |
| Open ground construction, on ground [RER] | 3167 m2 | ×0.34 / ×2.94 | lognormal, GSD² 3 | -23.2 / +68.2 | 192.1 (Land use) |
| Inverter, 500kW, at plant [RER] | 2.28 p | ×0.34 / ×2.94 | lognormal, GSD² 3 | -5.3 / +15.6 | 69.4 (Human toxicity, non-cancer_organics) |
| Electric installation, 570 kWp photovoltaic plant, at plant [ES] | 1 p | ×0.34 / ×2.94 | lognormal, GSD² 3 | -1.1 / +3.3 | 55.8 (Human toxicity, non-cancer_organics) |
| Treatment, c-Si PV module [RER] | 5.12e+04 kg | ×0.773 / ×1.29 | lognormal, GSD² 1.3 | -0.9 / +1.2 | 1.5 (Climate change-Land use and land use change) |
| Transport, freight, lorry, 7.5t-16t gross weight, fleet average [RER] | 9388 tkm | ×0.484 / ×2.06 | lognormal, GSD² 2.1 | -0.6 / +1.2 | 5.0 (Climate change-Land use and land use change) |
| Diesel, burned in building machine, average [CH] | 7673 MJ | ×0.506 / ×1.98 | lognormal, GSD² 2 | -0.1 / +0.2 | 0.6 (Human toxicity, non-cancer_organics) |
| Electricity, low voltage, production ENTSO-E, at grid [ENTSO-E] | 36.03 kWh | ×0.935 / ×1.07 | lognormal, GSD² 1.07 | -0.0 / +0.0 | 0.0 (Climate change-Biogenic) |
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
No other location of this dataset in the graph.
GWP100 3.470e+05 kg CO2 eq per p (95 % interval 2.167e+05–9.921e+05). Dominant contributors: Photovoltaic laminate, CdTe, mix, at regional storage 50 %; Open ground construction, on ground 35 %; Inverter, 500kW, at plant 8 %; Treatment, c-Si PV module 4 %; Electric installation, 570 kWp photovoltaic plant, at plant 2 %; Transport, freight, lorry, 7.5t-16t gross weight, fleet aver… 1 %. Most sensitive: Photovoltaic laminate, CdTe, mix, at regional storage [RER] (-32.8 / +96.8 %); Open ground construction, on ground [RER] (-23.2 / +68.2 %); Inverter, 500kW, at plant [RER] (-5.3 / +15.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 p |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 2.4e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 23/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 9/9 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 3.470e+05 in [2.167e+05, 9.921e+05] |
| time period declared | PASS | 2014-01/2018-12 |
| geography is a known location code | PASS | RER |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.