Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Poor concrete, at plant [CH], per 1 m3. EF v3.1 climate change 107.4 kg CO2 eq (Monte Carlo 95 % interval 85.46–147.6). Main contributors: Portland calcareous cement, at plant 87 %; Gravel, round, at mine 4 %; Diesel, burned in building machine, average 2 %; Transport, barge 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %; Concrete mixing plant 1 %. Status: final control passed.
Item Value
Dataset name Poor concrete, at plant
Dataset UUID / graph id 3d6b3acb-a4ef-344a-adb1-fde0cbecaa69 / activity:poor_concrete_at_plant__ch
Reference product, unit Poor concrete, at plant, 1 m3
Location CH
Time period 1997-01/1997-12
Category construction / concrete
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Part of total Swiss concrete production: insignificant. Density: 2'190 kg/m3. Ingredients: Cement 150 kg, Water 110 kg, Gravel 1'930 kg. Wastewater is an average from data on 11 German concrete mixing plant.; Synonyms: Transportbeton, Magerbeton, ready mixed concrete, poor concrete; UUID: 3d6b3acb-a4ef-344a-adb1-fde0cbecaa69

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m3 of Poor concrete, at plant (CH). All results are given per unit of the reference flow.

System boundary

includes the whole manufacturing processes to produce ready-mixed concrete, other internal processes (transport, etc.), and infrastructure (machines). No administration is included. Wastewater and some solid wastes are considered. No dust is accounted for.

Technology

Typical technology for average Swiss production

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Portland calcareous cement, at plant technosphere CH 150 kg lognormal, GSD² 1.3 (4,2,1,1,1,5) 87.2 █████████████████
Gravel, round, at mine technosphere CH 1930 kg lognormal, GSD² 1.3 (4,2,1,1,1,5) 4.5 █
Diesel, burned in building machine, average technosphere CH 20.9 MJ lognormal, GSD² 1.22 (2,1,1,2,1,5) 2.0 ·
Transport, barge technosphere RER 45.3 tkm lognormal, GSD² 2.05 (2,1,1,2,1,5) 1.6 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 8.69 tkm lognormal, GSD² 2.05 (2,1,1,1,1,5) 1.4 ·
Concrete mixing plant technosphere CH 4.2100e-07 p lognormal, GSD² 3.05 (2,1,1,1,1,5) 1.2 ·
Light fuel oil, burned in industrial furnace 1MW, non-modulating technosphere CH 12.2 MJ lognormal, GSD² 1.22 (2,1,1,1,1,5) 1.1 ·
Electricity, medium voltage, at grid technosphere CH 4.01 kWh lognormal, GSD² 1.22 (2,1,1,1,1,5) 0.3 ·
Heavy fuel oil, burned in industrial furnace 1MW, non-modulating technosphere CH 2.85 MJ lognormal, GSD² 1.22 (2,1,1,1,1,5) 0.3 ·
Transport, freight, lorry, 7.5t-16t gross weight, fleet average technosphere CH 0.92 tkm lognormal, GSD² 2.05 (2,1,1,1,1,5) 0.2 ·
Natural gas, burned in industrial furnace 1MW technosphere CH 1.07 MJ lognormal, GSD² 1.22 (2,1,1,2,1,5) 0.1 ·
Transport, freight, rail, electricity with shunting technosphere CH 6.28 tkm lognormal, GSD² 2.05 (2,1,1,1,1,5) 0.1 ·
Steel, low-alloyed, at plant technosphere RER 0.0219 kg lognormal, GSD² 1.22 (2,1,1,2,1,5) 0.0 ·
Disposal, municipal solid waste, 22.9% water, to municipal incineration technosphere CH 0.0876 kg lognormal, GSD² 1.22 (2,1,1,1,1,5) 0.0 ·
Synthetic rubber, at plant technosphere RER 0.00657 kg lognormal, GSD² 1.22 (2,1,1,2,1,5) 0.0 ·
Disposal, concrete, 5% water, to construction waste landfill technosphere CH 15.5 kg lognormal, GSD² 1.22 (2,1,1,1,1,5) 0.0 ·
Lubricating oil, at plant technosphere RER 0.0109 kg lognormal, GSD² 1.22 (2,1,1,2,1,5) 0.0 ·
Tap water, at user technosphere CH 110 kg lognormal, GSD² 1.3 (4,2,1,1,1,5) 0.0 ·
Treatment, concrete production effluent, to wastewater treatment, class 3 technosphere CH 0.0131 m3 lognormal, GSD² 1.22 (2,1,1,1,1,5) 0.0 ·
Waste Heat elementary air/Unknown 14.5 MJ lognormal, GSD² 1.22 (2,1,1,2,1,5) 0.0 ·

Data quality

20 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.3 · completeness 1.15 · temporal 1.0 · geographical 1.35 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Tina Kuenniger; data entry: Daniel Kellenberger; validation (proof reading): Roberto Dones
extrapolations See geography
sampling procedure Measured data of 6 Swiss plants
production volume na
uncertainty adjustments none
validation details Proof reading validation: passed; Other validation: none;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m3. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1033 0.08862 0.1614 1.35
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.07336 0.05607 0.1287 1.52
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 107.3 85.37 147.5 1.33
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.0191 0.01504 0.03116 1.44
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 107.4 85.46 147.6 1.33
EF-particulate Matter Impact on human health disease incidence 1.210e-06 1.085e-06 1.889e-06 1.34
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 76.65 64.48 173 1.62
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.606 2.309 4.775 1.47
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 79.26 67.45 175.6 1.6
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.06987 0.05478 0.104 1.39
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.01911 0.01034 0.07446 2.75
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.7114 0.5711 1.035 1.36
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.587e-09 5.453e-09 2.218e-08 2.09
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.325e-09 4.807e-09 9.302e-09 1.42
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.191e-08 1.095e-08 2.997e-08 1.7
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 5.622e-07 3.593e-07 2.112e-06 2.55
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.765e-08 3.001e-08 7.034e-08 1.54
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 5.999e-07 3.997e-07 2.162e-06 2.45
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 16.72 6.174 97.33 4.19
Land use Soil quality index pt (soil quality index) 446.7 213.3 973.2 2.26
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 6.616e-07 5.877e-07 9.538e-07 1.27
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.2324 0.1908 0.354 1.37
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 460.7 415.8 625.6 1.24
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 8.180e-05 4.722e-05 2.752e-04 2.55
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 2.785 -6242 3359 —

Climate change 107.4 kg CO2 eq per m3. Main contributors: Portland calcareous cement, at plant 87 %; Gravel, round, at mine 4 %; Diesel, burned in building machine, average 2 %; Transport, barge 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %; Concrete mixing plant 1 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Portland calcareous cement, at plant 87 %; Gravel, round, at mine 4 %; Diesel, burned in building machine, average 2 %; Transport, barge 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %; Concrete mixing plant 1 %. Most sensitive exchanges (Section 6.3): Portland calcareous cement, at plant [CH] (-19.8 / +25.6 %); Concrete mixing plant [CH] (-0.8 / +2.3 %); Transport, barge [RER] (-0.8 / +1.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.1033 0.2064 0.500
Climate change-Biogenic 0.07336 0.07336 1.000
Climate change-Fossil 107.3 107.3 1.000
Climate change-Land use and land use change 0.0191 0.0191 1.000
Climate change 107.4 107.4 1.000
EF-particulate Matter 1.210e-06 1.210e-06 1.000
Ecotoxicity, freshwater_inorganics 76.65 78.43 0.977
Ecotoxicity, freshwater_organics 2.606 2.593 1.005
Ecotoxicity, freshwater 79.26 80.97 0.979
Eutrophication marine 0.06987 0.06986 1.000
Eutrophication, freshwater 0.01911 0.01911 1.000
Eutrophication, terrestrial 0.7114 0.8108 0.877
Human toxicity, cancer_inorganics 6.587e-09 6.425e-09 1.025
Human toxicity, cancer_organics 5.325e-09 5.325e-09 1.000
Human toxicity, cancer 1.191e-08 1.175e-08 1.014
Human toxicity, non-cancer_inorganics 5.622e-07 5.566e-07 1.010
Human toxicity, non-cancer_organics 3.765e-08 3.765e-08 1.000
Human toxicity, non-cancer 5.999e-07 5.942e-07 1.010
Ionising radiation, human health 16.72 16.72 1.000
Land use 446.7 248.6 1.797
Ozone depletion 6.616e-07 6.616e-07 1.000
Photochemical ozone formation - human health 0.2324 0.2324 1.000
Resource use, fossils 460.7 460.7 1.000
Resource use, minerals and metals 8.180e-05 8.080e-05 1.012
Water use 2.785 10.15 0.274
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 107.4 kg CO2 eq; Ecological Scarcity
2021 total 1.947e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Portland calcareous cement, at plant [CH] 150 kg ×0.773 / ×1.29 lognormal, GSD² 1.3 -19.8 / +25.6 25.6 (Climate change-Fossil)
Concrete mixing plant [CH] 4.210e-07 p ×0.335 / ×2.98 lognormal, GSD² 3.05 -0.8 / +2.3 93.3 (Resource use, minerals and metals)
Transport, barge [RER] 45.3 tkm ×0.495 / ×2.02 lognormal, GSD² 2.05 -0.8 / +1.6 38.3 (Climate change-Land use and land use change)
Gravel, round, at mine [CH] 1930 kg ×0.773 / ×1.29 lognormal, GSD² 1.3 -1.0 / +1.3 16.4 (Land use)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 8.69 tkm ×0.495 / ×2.02 lognormal, GSD² 2.05 -0.7 / +1.4 11.8 (Ecotoxicity, freshwater_organics)
Diesel, burned in building machine, average [CH] 20.9 MJ ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.4 / +0.4 4.2 (Human toxicity, non-cancer_organics)
Light fuel oil, burned in industrial furnace 1MW, non-modulating [CH] 12.2 MJ ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.2 / +0.2 0.8 (Ozone depletion)
Transport, freight, lorry, 7.5t-16t gross weight, fleet average [CH] 0.92 tkm ×0.495 / ×2.02 lognormal, GSD² 2.05 -0.1 / +0.3 1.9 (Ecotoxicity, freshwater_organics)
Electricity, medium voltage, at grid [CH] 4.01 kWh ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.1 / +0.1 3.5 (Ionising radiation, human health)
Heavy fuel oil, burned in industrial furnace 1MW, non-modulating [CH] 2.85 MJ ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.0 / +0.1 0.3 (EF-particulate Matter)
Transport, freight, rail, electricity with shunting [CH] 6.28 tkm ×0.495 / ×2.02 lognormal, GSD² 2.05 -0.0 / +0.1 1.0 (Climate change-Land use and land use change)
Natural gas, burned in industrial furnace 1MW [CH] 1.07 MJ ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.0 / +0.0 0.1 (Ozone depletion)
Steel, low-alloyed, at plant [RER] 0.0219 kg ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.0 / +0.0 0.1 (Resource use, minerals and metals)
Disposal, municipal solid waste, 22.9% water, to municipal incineration [CH] 0.0876 kg ×0.823 / ×1.22 lognormal, GSD² 1.22 -0.0 / +0.0 0.1 (Ecotoxicity, freshwater_inorganics)
Tap water, at user [CH] 110 kg ×0.773 / ×1.29 lognormal, GSD² 1.3 -0.0 / +0.0 0.4 (Water use)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 107.4 kg CO2 eq per m3 (95 % interval 85.46–147.6). Dominant contributors: Portland calcareous cement, at plant 87 %; Gravel, round, at mine 4 %; Diesel, burned in building machine, average 2 %; Transport, barge 2 %; Transport, freight, lorry, 16t-32t gross weight, fleet avera… 1 %; Concrete mixing plant 1 %. Most sensitive: Portland calcareous cement, at plant [CH] (-19.8 / +25.6 %); Concrete mixing plant [CH] (-0.8 / +2.3 %); Transport, barge [RER] (-0.8 / +1.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m3
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 1.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 107.4 in [85.46, 147.6]
time period declared PASS 1997-01/1997-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Kellenberger D., Althaus H.-J., Jungbluth N., Künniger T. (2007) Life Cycle Inventories of Building Products. Final report ecoinvent data v2.0. Volume: 7. Swiss Centre for LCI, Empa - TSL. Dübendorf, CH. Type: Measurement on site Source: CD-ROM First author: Kellenberger D. Other authors: Althaus H.-J., Jungbluth N., Künniger T. Year: 2007 Title of anthology: Final report ecoinvent data v2.0 Place… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.