Table of Contents

Ventilation unit 6700 m3/h, w. heat excanger, at plant — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation unit 6700 m3/h, w. heat excanger, at plant [CH], per 1 m3. EF v3.1 climate change 1.531 kg CO2 eq (Monte Carlo 95 % interval 1.464–1.892). Main contributors: Aluminium, production mix, wrought alloy, at plant 22 %; Steel, converter, unalloyed, at plant 16 %; Powder coating, aluminium sheet 12 %; Metal working factory operation, average heat energy 5 %; Zinc coating, coils 4 %; Control and wiring, central unit, at plant 4 %. Status: final control passed.
Item Value
Dataset name Ventilation unit 6700 m3/h, w. heat excanger, at plant
Dataset UUID / graph id 3f04ff8c-6b6a-3705-8fe6-928968137e5a / activity:ventilation_unit_6700_m3_h_w_heat_excanger_at_plant__ch
Reference product, unit Ventilation unit 6700 m3/h, w. heat excanger, at plant, 1 m3
Location CH
Time period 2014-01/2014-12
Category ventilation / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of a ventilation unit (air handling unit) with 6700 m3/h nominal air flow rate (at 2 m/s air speed in cross section of air filter or heat exchanger). Reference value of inventory is 1 m3/h air flow. Specific component weight: 0.26 kg/(m3/h), total weight: 0.3 kg/(m3/h), including average components for controls, inverter and electric control cabinet, material for 20 filter replacements (once a year for 20 years lifetime). The air handling unit includes a frame construction, two radial belt drive fans, two multi-leaf damper, heat recovery with average heat exchanger (average of plate, rotary and circuit connected heat exchanger), heating elements, expansion plenum and empty section in supply and extract air. No cooling elements, humidifier, air-mixing plenum and silencer included. The frame construction made of aluminium-profiles, casing made of hot-dip galvanized and powder coated steel sheets insulated with polyurethane foam.; UUID: 3f04ff8c-6b6a-3705-8fe6-928968137e5a

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m3 of Ventilation unit 6700 m3/h, w. heat excanger, at plant (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.

Technology

Typical technology, materials and components used for ventilation systems in commercial and public buildings

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Aluminium, production mix, wrought alloy, at plant technosphere RER 0.067391 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 21.9 ████
Steel, converter, unalloyed, at plant technosphere RER 0.10406 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 16.4 ███
Powder coating, aluminium sheet technosphere RER 0.052018 m2 lognormal, GSD² 1.32 (4,4,1,1,1,5) 11.5 ██
Metal working factory operation, average heat energy technosphere RER 0.30061 kg lognormal, GSD² 1.27 (2,4,2,1,3,4) 5.1 █
Zinc coating, coils technosphere RER 0.016904 m2 lognormal, GSD² 1.26 (3,4,1,1,1,5) 4.5 █
Control and wiring, central unit, at plant technosphere RER 0.0027778 p lognormal, GSD² 1.34 (3,4,1,1,3,5) 4.3 █
Sheet rolling, steel technosphere RER 0.16518 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 4.1 █
Electric motor, electric vehicle, at plant technosphere RER 0.021493 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.0 █
Inverter, 2500W, at plant technosphere RER 4.1791e-04 p lognormal, GSD² 1.34 (3,4,1,1,3,5) 4.0 █
Fleece production, polyethylene terephthalate technosphere RER 0.016626 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 3.9 █
Powder coating, steel technosphere RER 0.012589 m2 lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.4 █
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 0.18036 kWh lognormal, GSD² 1.34 (3,4,1,1,3,5) 3.2 █
Polyethylene terephthalate, granulate, amorphous, at plant technosphere RER 0.016626 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.0 █
Polyurethane, rigid foam, at plant technosphere RER 0.0084202 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.4 ·
Steel, electric, un- and low-alloyed, at plant technosphere RER 0.061116 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.2 ·
Section bar extrusion, aluminium technosphere RER 0.039301 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.8 ·
Copper, at regional storage technosphere RER 0.010287 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.1 ·
Metal working factory technosphere RER 1.3768e-10 p lognormal, GSD² 3.07 (2,4,2,1,3,4) 0.9 ·
Sheet rolling, aluminium technosphere RER 0.028089 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.8 ·
Zinc coating, pieces, adjustment per um technosphere RER -0.25862 m2 lognormal, GSD² 1.26 (3,4,1,1,1,5) -0.8 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 0.055946 tkm lognormal, GSD² 2.14 (4,5,1,1,1,5) 0.6 ·
Glass fibre reinforced plastic, polyamide, injection moulding, at plant technosphere RER 0.001048 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.6 ·
Chromium steel 18/8, at plant technosphere RER 0.0011798 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.3 ·
Drawing of pipes, steel technosphere RER 0.010287 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.3 ·
Transport, freight, rail technosphere RER 0.13455 tkm lognormal, GSD² 2.14 (4,5,1,1,1,5) 0.1 ·
Synthetic rubber, at plant technosphere RER 6.7110e-04 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.1 ·
Pump 40W, at plant technosphere CH 1.9900e-04 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.1 ·
Sawnwood, production mix, softwood, dried (u=10%), planed, at sawmill technosphere RER 1.6794e-05 m3 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Sheet rolling, chromium steel technosphere RER 0.0011798 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.0 ·
Waste Heat elementary air/Ground level / Urban (>1000 people/s… 0.64931 MJ lognormal, GSD² 1.34 (3,4,1,1,3,5) 0.0 ·

Data quality

30 of 30 direct exchanges carry a declared pedigree, 30 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.8 · completeness 4.07 · temporal 1.07 · geographical 1.0 · technological 1.47 · sample size 4.93.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Manufacturer informations and literature data. Data of typical product used.
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Process information from 2003 to 2012

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m3. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.01329 0.01076 0.02123 1.42
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.005961 0.004079 0.01345 1.79
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.525 1.457 1.883 1.14
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.515e-04 6.465e-04 0.001358 1.49
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.531 1.464 1.892 1.14
EF-particulate Matter Impact on human health disease incidence 1.289e-07 1.083e-07 2.019e-07 1.35
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 8.745 8.549 14.51 1.32
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.1876 0.1767 0.3351 1.41
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 8.932 8.737 14.77 1.32
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.001493 0.00142 0.002077 1.22
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.001703 0.001205 0.009761 2.89
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.03674 0.02503 0.0707 1.69
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.207e-09 1.139e-09 3.004e-09 1.69
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.080e-10 4.554e-10 8.220e-10 1.37
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.715e-09 1.686e-09 3.667e-09 1.5
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.962e-08 6.568e-08 1.724e-07 1.62
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.101e-09 2.938e-09 7.238e-09 1.6
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 7.372e-08 7.065e-08 1.770e-07 1.59
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.535 0.1982 3.375 4.27
Land use Soil quality index pt (soil quality index) 8.925 8.107 15.5 1.38
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 4.808e-08 4.325e-08 7.587e-08 1.33
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.004714 0.004525 0.006869 1.23
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 21.7 20.18 31.03 1.24
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 6.414e-05 3.851e-05 1.173e-04 1.78
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.1967 -304.5 157.4 —

Climate change 1.531 kg CO2 eq per m3. Main contributors: Aluminium, production mix, wrought alloy, at plant 22 %; Steel, converter, unalloyed, at plant 16 %; Powder coating, aluminium sheet 12 %; Metal working factory operation, average heat energy 5 %; Zinc coating, coils 4 %; Control and wiring, central unit, at plant 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Aluminium, production mix, wrought alloy, at plant 22 %; Steel, converter, unalloyed, at plant 16 %; Powder coating, aluminium sheet 12 %; Metal working factory operation, average heat energy 5 %; Zinc coating, coils 4 %; Control and wiring, central unit, at plant 4 %. Most sensitive exchanges (Section 6.3): Aluminium, production mix, wrought alloy, at plant [RER] (-4.2 / +5.1 %); Steel, converter, unalloyed, at plant [RER] (-3.1 / +3.8 %); Powder coating, aluminium sheet [RER] (-2.7 / +3.6 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.01329 0.01389 0.956
Climate change-Biogenic 0.005961 0.005961 1.000
Climate change-Fossil 1.525 1.525 1.000
Climate change-Land use and land use change 8.515e-04 8.515e-04 1.000
Climate change 1.531 1.531 1.000
EF-particulate Matter 1.289e-07 1.289e-07 1.000
Ecotoxicity, freshwater_inorganics 8.745 8.835 0.990
Ecotoxicity, freshwater_organics 0.1876 0.1635 1.147
Ecotoxicity, freshwater 8.932 8.984 0.994
Eutrophication marine 0.001493 0.001493 1.000
Eutrophication, freshwater 0.001703 0.001703 1.000
Eutrophication, terrestrial 0.03674 0.03751 0.980
Human toxicity, cancer_inorganics 1.207e-09 1.200e-09 1.006
Human toxicity, cancer_organics 5.080e-10 5.078e-10 1.000
Human toxicity, cancer 1.715e-09 1.708e-09 1.004
Human toxicity, non-cancer_inorganics 6.962e-08 6.933e-08 1.004
Human toxicity, non-cancer_organics 4.101e-09 4.100e-09 1.000
Human toxicity, non-cancer 7.372e-08 7.343e-08 1.004
Ionising radiation, human health 0.535 0.535 1.000
Land use 8.925 7.791 1.146
Ozone depletion 4.808e-08 4.808e-08 1.000
Photochemical ozone formation - human health 0.004714 0.004714 1.000
Resource use, fossils 21.7 21.7 1.000
Resource use, minerals and metals 6.414e-05 6.325e-05 1.014
Water use 0.1967 0.2149 0.915
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 1.531 kg CO2 eq; Ecological Scarcity
2021 total 3645 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Aluminium, production mix, wrought alloy, at plant [RER] 0.06739 kg ×0.81 / ×1.23 lognormal, GSD² 1.24 -4.2 / +5.1 12.7 (Climate change-Land use and land use change)
Steel, converter, unalloyed, at plant [RER] 0.1041 kg ×0.81 / ×1.23 lognormal, GSD² 1.24 -3.1 / +3.8 6.5 (Human toxicity, cancer_organics)
Powder coating, aluminium sheet [RER] 0.05202 m2 ×0.762 / ×1.31 lognormal, GSD² 1.32 -2.7 / +3.6 5.3 (Ecotoxicity, freshwater_organics)
Control and wiring, central unit, at plant [RER] 0.002778 p ×0.751 / ×1.33 lognormal, GSD² 1.34 -1.1 / +1.4 12.3 (Resource use, minerals and metals)
Metal working factory operation, average heat energy [RER] 0.3006 kg ×0.791 / ×1.26 lognormal, GSD² 1.27 -1.1 / +1.3 6.5 (Water use)
Metal working factory [RER] 1.377e-10 p ×0.333 / ×3 lognormal, GSD² 3.07 -0.6 / +1.8 37.9 (Land use)
Inverter, 2500W, at plant [RER] 4.179e-04 p ×0.751 / ×1.33 lognormal, GSD² 1.34 -1.0 / +1.3 9.7 (Resource use, minerals and metals)
Fleece production, polyethylene terephthalate [RER] 0.01663 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -1.0 / +1.3 3.6 (Climate change-Biogenic)
Zinc coating, coils [RER] 0.0169 m2 ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.9 / +1.1 17.8 (Eutrophication, terrestrial)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 0.1804 kWh ×0.751 / ×1.33 lognormal, GSD² 1.34 -0.8 / +1.1 4.7 (Climate change-Biogenic)
Sheet rolling, steel [RER] 0.1652 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.8 / +1.0 1.8 (Water use)
Electric motor, electric vehicle, at plant [RER] 0.02149 kg ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.8 / +0.9 1.9 (Human toxicity, non-cancer_organics)
Powder coating, steel [RER] 0.01259 m2 ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.7 / +0.9 2.8 (Ozone depletion)
Polyethylene terephthalate, granulate, amorphous, at plant [RER] 0.01663 kg ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.7 2.0 (Ecotoxicity, freshwater_organics)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 0.05595 tkm ×0.474 / ×2.11 lognormal, GSD² 2.14 -0.3 / +0.7 1.4 (Photochemical ozone formation - human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 1.531 kg CO2 eq per m3 (95 % interval 1.464–1.892). Dominant contributors: Aluminium, production mix, wrought alloy, at plant 22 %; Steel, converter, unalloyed, at plant 16 %; Powder coating, aluminium sheet 12 %; Metal working factory operation, average heat energy 5 %; Zinc coating, coils 4 %; Control and wiring, central unit, at plant 4 %. Most sensitive: Aluminium, production mix, wrought alloy, at plant [RER] (-4.2 / +5.1 %); Steel, converter, unalloyed, at plant [RER] (-3.1 / +3.8 %); Powder coating, aluminium sheet [RER] (-2.7 / +3.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m3
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 5.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 22/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 30/30 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 1.531 in [1.464, 1.892]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.