Table of Contents

Printed wiring board, mounted, Desktop PC mainboard, Pb containing, at plant — GLO

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Printed wiring board, mounted, Desktop PC mainboard, Pb containing, at plant [GLO], per 1 kg. EF v3.1 climate change 111.2 kg CO2 eq (Monte Carlo 95 % interval 103.2–144.7). Main contributors: Integrated circuit, IC, logic type, at plant 44 %; Printed wiring board, surface mount, lead-containing surface… 19 %; Connector, PCI bus, at plant 8 %; Capacitor, electrolyte type, < 2cm height, at plant 7 %; Capacitor, Tantalum-, through-hole mounting, at plant 7 %; Integrated circuit, IC, memory type, at plant 6 %. Status: final control passed.
Item Value
Dataset name Printed wiring board, mounted, Desktop PC mainboard, Pb containing, at plant
Dataset UUID / graph id 51325b60-e32b-3be2-b7f8-38a7ec8e1255 / activity:printed_wiring_board_mounted_desktop_pc_mainboard_pb_containing_at_plant__glo
Reference product, unit Printed wiring board, mounted, Desktop PC mainboard, Pb containing, at plant, 1 kg
Location GLO
Time period 2004-01/2004-12
Category electronics / devices\module\pwb
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The data represent a typical Desktop PC mainboard, used in modern computers. Material data are taken from the literature and own dismantling activities. Infrastructure and production efforts are based on own assumptions.; UUID: 51325b60-e32b-3be2-b7f8-38a7ec8e1255

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Printed wiring board, mounted, Desktop PC mainboard, Pb containing, at plant (GLO). All results are given per unit of the reference flow.

System boundary

This dataset covers component input and production efforts (incl. PWB waste due to failure in mounting) for the production of Desktop PC mainboards, using Pb-containing solder material.

Technology

average PWB mounting technology (solder paste production line)

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Integrated circuit, IC, logic type, at plant technosphere GLO 0.081633 kg lognormal, GSD² 1.24 — 44.2 █████████
Printed wiring board, surface mount, lead-containing surface, at plant technosphere GLO 0.10955 m2 lognormal, GSD² 1.22 — 18.8 ████
Connector, PCI bus, at plant technosphere GLO 0.18367 kg lognormal, GSD² 1.24 — 8.3 ██
Capacitor, electrolyte type, < 2cm height, at plant technosphere GLO 0.18286 kg lognormal, GSD² 1.24 — 7.0 █
Capacitor, Tantalum-, through-hole mounting, at plant technosphere GLO 0.045714 kg lognormal, GSD² 1.24 — 6.6 █
Integrated circuit, IC, memory type, at plant technosphere GLO 0.020408 kg lognormal, GSD² 1.24 — 6.4 █
Transistor, wired, small size, through-hole mounting, at plant technosphere GLO 0.045714 kg lognormal, GSD² 1.24 — 4.5 █
Resistor, SMD type, surface mounting, at plant technosphere GLO 0.01102 kg lognormal, GSD² 1.24 — 1.6 ·
Mounting, through-hole technology, Pb-containing solder technosphere GLO 0.016433 m2 lognormal, GSD² 1.24 — 0.6 ·
Capacitor, SMD type, surface-mounting, at plant technosphere GLO 0.01102 kg lognormal, GSD² 1.24 — 0.5 ·
Inductor, ring core choke type, at plant technosphere GLO 0.011429 kg lognormal, GSD² 1.24 — 0.4 ·
Connector, computer, peripherical type, at plant technosphere GLO 0.061224 kg lognormal, GSD² 1.24 — 0.4 ·
Diode, glass-, SMD type, surface mounting, at plant technosphere GLO 0.0017143 kg lognormal, GSD² 1.24 — 0.3 ·
Mounting, surface mount technology, Pb-containing solder technosphere GLO 0.09312 m2 lognormal, GSD² 1.24 — 0.3 ·
Light emitting diode, LED, at plant technosphere GLO 7.3469e-04 kg lognormal, GSD² 1.24 — 0.1 ·
Transport, freight, lorry, fleet average technosphere RER 0.13265 tkm lognormal, GSD² 2.1 — 0.0 ·
Transport, transoceanic freight ship technosphere OCE 0.80612 tkm lognormal, GSD² 2.1 — 0.0 ·
Transport, freight, rail technosphere RER 0.14286 tkm lognormal, GSD² 2.1 — 0.0 ·
Disposal, treatment of printed wiring boards technosphere GLO 0.020408 kg lognormal, GSD² 1.24 — 0.0 ·

Data quality

0 of 19 direct exchanges carry a declared pedigree, 19 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Roland Hischier (EMPA); data entry: Roland Hischier (EMPA); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations see Geography & Technology
sampling procedure literature & own dismantling
production volume na
uncertainty adjustments
validation details Proof reading validation: passed.; Other validation: none;
time period comment undefined

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.4795 0.4434 0.6759 1.25
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.6385 0.3682 1.663 2.15
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 110.5 102.5 143.7 1.19
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.05293 0.04385 0.08205 1.37
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 111.2 103.2 144.7 1.19
EF-particulate Matter Impact on human health disease incidence 3.746e-06 3.540e-06 6.012e-06 1.31
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 849.3 814.5 1907 1.57
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 18.6 17.03 29.32 1.34
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 867.9 835.7 1930 1.56
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.1571 0.1374 0.2863 1.49
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.5946 0.3494 3.775 3.44
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1.406 1.185 2.174 1.38
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.116e-07 1.046e-07 3.634e-07 1.91
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.402e-08 3.851e-08 6.575e-08 1.32
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.556e-07 1.524e-07 4.105e-07 1.7
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 8.358e-06 6.833e-06 3.111e-05 2.17
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.804e-07 1.533e-07 2.891e-07 1.39
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 8.538e-06 7.029e-06 3.133e-05 2.14
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 33.77 11.44 219.9 4.6
Land use Soil quality index pt (soil quality index) 1171 884.1 2091 1.56
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.038e-05 7.984e-06 1.653e-05 1.44
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.4944 0.4504 0.7235 1.27
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 1558 1435 2266 1.26
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.0965 0.07899 0.1277 1.29
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 19.51 -2.998e+04 1.57e+04 —

Climate change 111.2 kg CO2 eq per kg. Main contributors: Integrated circuit, IC, logic type, at plant 44 %; Printed wiring board, surface mount, lead-containing surface… 19 %; Connector, PCI bus, at plant 8 %; Capacitor, electrolyte type, < 2cm height, at plant 7 %; Capacitor, Tantalum-, through-hole mounting, at plant 7 %; Integrated circuit, IC, memory type, at plant 6 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Integrated circuit, IC, logic type, at plant 44 %; Printed wiring board, surface mount, lead-containing surface… 19 %; Connector, PCI bus, at plant 8 %; Capacitor, electrolyte type, < 2cm height, at plant 7 %; Capacitor, Tantalum-, through-hole mounting, at plant 7 %; Integrated circuit, IC, memory type, at plant 6 %. Most sensitive exchanges (Section 6.3): Integrated circuit, IC, logic type, at plant [GLO] (-8.5 / +10.5 %); Printed wiring board, surface mount, lead-containing surface, at plant [GLO] (-3.3 / +4.0 %); Connector, PCI bus, at plant [GLO] (-1.6 / +2.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.4795 0.8154 0.588
Climate change-Biogenic 0.6385 0.6385 1.000
Climate change-Fossil 110.5 110.5 1.000
Climate change-Land use and land use change 0.05293 0.05293 1.000
Climate change 111.2 111.2 1.000
EF-particulate Matter 3.746e-06 3.746e-06 1.000
Ecotoxicity, freshwater_inorganics 849.3 874.6 0.971
Ecotoxicity, freshwater_organics 18.6 15.42 1.206
Ecotoxicity, freshwater 867.9 859.5 1.010
Eutrophication marine 0.1571 0.1571 1.000
Eutrophication, freshwater 0.5946 0.5946 1.000
Eutrophication, terrestrial 1.406 1.501 0.936
Human toxicity, cancer_inorganics 1.116e-07 1.104e-07 1.010
Human toxicity, cancer_organics 4.402e-08 4.402e-08 1.000
Human toxicity, cancer 1.556e-07 1.545e-07 1.007
Human toxicity, non-cancer_inorganics 8.358e-06 8.258e-06 1.012
Human toxicity, non-cancer_organics 1.804e-07 1.803e-07 1.000
Human toxicity, non-cancer 8.538e-06 8.438e-06 1.012
Ionising radiation, human health 33.77 33.77 1.000
Land use 1171 1033 1.133
Ozone depletion 1.038e-05 1.038e-05 1.000
Photochemical ozone formation - human health 0.4944 0.4944 1.000
Resource use, fossils 1558 1559 0.999
Resource use, minerals and metals 0.0965 0.0964 1.001
Water use 19.51 22.91 0.851
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 111.1 kg CO2 eq; Ecological Scarcity
2021 total 5.906e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Integrated circuit, IC, logic type, at plant [GLO] 0.08163 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -8.5 / +10.5 13.1 (Ozone depletion)
Printed wiring board, surface mount, lead-containing surface, at plant [GLO] 0.1095 m2 ×0.825 / ×1.21 lognormal, GSD² 1.22 -3.3 / +4.0 9.6 (Ionising radiation, human health)
Connector, PCI bus, at plant [GLO] 0.1837 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -1.6 / +2.0 5.4 (Resource use, minerals and metals)
Capacitor, electrolyte type, < 2cm height, at plant [GLO] 0.1829 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -1.4 / +1.7 3.0 (Climate change-Land use and land use change)
Capacitor, Tantalum-, through-hole mounting, at plant [GLO] 0.04571 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -1.3 / +1.6 4.8 (Land use)
Integrated circuit, IC, memory type, at plant [GLO] 0.02041 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -1.2 / +1.5 3.0 (Ozone depletion)
Transistor, wired, small size, through-hole mounting, at plant [GLO] 0.04571 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.9 / +1.1 2.0 (Climate change-Land use and land use change)
Resistor, SMD type, surface mounting, at plant [GLO] 0.01102 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.3 / +0.4 1.2 (EF-particulate Matter)
Mounting, through-hole technology, Pb-containing solder [GLO] 0.01643 m2 ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.2 0.6 (Ionising radiation, human health)
Capacitor, SMD type, surface-mounting, at plant [GLO] 0.01102 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.1 0.7 (Human toxicity, non-cancer_organics)
Inductor, ring core choke type, at plant [GLO] 0.01143 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.1 0.1 (Photochemical ozone formation - human health)
Connector, computer, peripherical type, at plant [GLO] 0.06122 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.1 0.6 (Human toxicity, non-cancer_organics)
Diode, glass-, SMD type, surface mounting, at plant [GLO] 0.001714 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.1 0.1 (Climate change-Land use and land use change)
Mounting, surface mount technology, Pb-containing solder [GLO] 0.09312 m2 ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.1 / +0.1 4.5 (Human toxicity, cancer_organics)
Light emitting diode, LED, at plant [GLO] 7.347e-04 kg ×0.808 / ×1.24 lognormal, GSD² 1.24 -0.0 / +0.0 0.0 (Climate change-Land use and land use change)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 111.2 kg CO2 eq per kg (95 % interval 103.2–144.7). Dominant contributors: Integrated circuit, IC, logic type, at plant 44 %; Printed wiring board, surface mount, lead-containing surface… 19 %; Connector, PCI bus, at plant 8 %; Capacitor, electrolyte type, < 2cm height, at plant 7 %; Capacitor, Tantalum-, through-hole mounting, at plant 7 %; Integrated circuit, IC, memory type, at plant 6 %. Most sensitive: Integrated circuit, IC, logic type, at plant [GLO] (-8.5 / +10.5 %); Printed wiring board, surface mount, lead-containing surface, at plant [GLO] (-3.3 / +4.0 %); Connector, PCI bus, at plant [GLO] (-1.6 / +2.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 20/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 19/19 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 111.2 in [103.2, 144.7]
time period declared PASS 2004-01/2004-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Hischier R., Classen M., Lehmann M., Scharnhorst W. (2007) Life Cycle Inventories of Electric and Electronic Equipment - Production, Use & Disposal. Final report ecoinvent Data v2.0. Volume: 18. Swiss Centre for LCI, Empa - TSL. Duebendorf and St. Gallen, CH. Type: Measurement on site Source: CD-ROM First author: Hischier R. Other authors: Classen M., Lehmann M., Scharnhorst W. Year: 2007 Title of… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.