Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Disposal, ventilation system for appartment buildings, steel ducts, without GHE [CH], per 1 m2. EF v3.1 climate change 0.2974 kg CO2 eq (Monte Carlo 95 % interval 0.2503–0.367). Main contributors: Disposal, ventilation equipment, decentralized, 180-250 m3 39 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 38 %; Disposal, overflow element, steel, approx. 40 m3/h 6 %; Disposal, air distribution housing, steel, 120 m3/h 3 %; Disposal, control and wiring, decentralized unit 3 %; Disposal, flexible duct, aluminum/PET, DN of 125 2 %. Status: final control passed.
Item Value
Dataset name Disposal, ventilation system for appartment buildings, steel ducts, without GHE
Dataset UUID / graph id 62698e20-cc0e-4926-b549-73a47a009d0e / activity:disposal_ventilation_system_for_appartment_buildings_steel_ducts_without_ghe__ch
Reference product, unit Disposal, ventilation system for appartment buildings, steel ducts, without GHE, 1 m2
Location CH — Specific to the technology mix encountered in sorting plants in Switzerland.
Time period 1994-01/2008-12
Category waste management / building demolition
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Disposal of a ventilation system for an appartment building with a specific air flow rate of 0.92 m3/h per m2 heated gross floor area. The reference value of the inventory is 1 m2 heated gross floor area. The inventory is based on a study of an appartment building with 6 flats, a heated gross floor area of 780 m2 and a total nominal air flow of 720 m3/h. The inventory includes an average of decentral and central systems. It includes average components for air handling units, ducts (including 30mm thermal insulation where needed), air valves, roof-hoods, dampers and silencers. No insuation for fire protection or fire dampers included. The data represent a ductwork mainly made of galvanized steel and includes compact air handling units with cross plate heat excangers as heat recovery and a nominal air flow rate of 200-1200 m3/h per unit. No ground heat exchanger, ventilation of side rooms, cellars or car parks are included.; UUID: 62698e20-cc0e-4926-b549-73a47a009d0e

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Disposal, ventilation system for appartment buildings, steel ducts, without GHE (CH). All results are given per unit of the reference flow.

System boundary

Transport to dismantling facilities, machines for handling in sorting plant, electricity demand for sorting plant, final disposal of waste material. Cut-off to recycling for metals.

Technology

Disposal to a sorting plant assumed. Metal pieces, copper in cables and electronic devices are recycled, plastic parts are incinerated, inert wastes (e.g. rock wool) are landfilled.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Disposal, ventilation equipment, decentralized, 180-250 m3 technosphere CH 0.0038462 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 39.3 ████████
Disposal, sealing tape, aluminum/PE, 50 mm wide technosphere CH 0.89744 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 37.6 ████████
Disposal, overflow element, steel, approx. 40 m3/h technosphere CH 0.023077 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.2 █
Disposal, air distribution housing, steel, 120 m3/h technosphere CH 0.015385 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.0 █
Disposal, control and wiring, decentralized unit technosphere CH 0.0038462 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.7 █
Disposal, flexible duct, aluminum/PET, DN of 125 technosphere CH 0.025641 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.3 ·
Disposal, outside air intake, stainless steel, DN 370 technosphere CH 9.6154e-04 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.0 ·
Disposal, building, bulk iron (excluding reinforcement), to sorting plant technosphere CH 1.6442 kg lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.9 ·
Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 technosphere CH 0.023077 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.4 ·
Disposal, control and wiring, central unit technosphere CH 6.4103e-04 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.9 ·
Disposal, ventilation equipment, central, 600-1200 m3/h technosphere CH 6.4103e-04 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.7 ·
Disposal, air filter, decentralized unit, 180-250 m3/h technosphere CH 0.0076923 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.7 ·
Disposal, air filter, in exhaust air valve technosphere CH 0.023077 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.6 ·
Disposal, silencer, steel, DN 125 technosphere CH 0.023077 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.4 ·
Disposal, insulation spiral-seam duct, rockwool, DN 400, 30 mm technosphere CH 0.025641 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.3 ·
Disposal, silencer, steel, DN 315, 50 mm technosphere CH 0.0012821 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, air filter, central unit, 600 m3/h technosphere CH 0.0012821 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Disposal, exhaust air roof hood, steel, DN 400 technosphere CH 9.6154e-04 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·

Data quality

18 of 18 direct exchanges carry a declared pedigree, 18 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Waste-specific calculation based on production input data
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2003. Process information partly from 2008. Disposal technology mix as used in late 1990ies

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 3.692e-05 3.522e-05 5.605e-05 1.27
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.094e-05 2.389e-05 5.677e-05 1.54
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2973 0.2502 0.367 1.22
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 5.300e-06 4.515e-06 8.236e-06 1.36
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.2974 0.2503 0.367 1.22
EF-particulate Matter Impact on human health disease incidence 1.255e-09 9.909e-10 2.299e-09 1.51
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.8828 0.7453 1.289 1.32
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.002172 0.001863 0.004077 1.5
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.885 0.7484 1.292 1.32
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 3.741e-05 3.262e-05 6.213e-05 1.39
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 8.306e-06 2.837e-06 2.103e-04 9.41
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 2.915e-04 2.538e-04 4.943e-04 1.4
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.442e-10 5.119e-11 8.668e-10 4.51
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 2.164e-12 2.093e-12 3.246e-12 1.25
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.464e-10 5.389e-11 8.701e-10 4.41
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 9.768e-10 8.779e-10 3.895e-09 2.11
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.336e-11 1.198e-11 1.885e-11 1.27
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 9.901e-10 8.936e-10 3.911e-09 2.09
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.005374 0.002005 0.03047 4.16
Land use Soil quality index pt (soil quality index) 0.1642 0.1065 0.2618 1.57
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.387e-10 4.913e-10 7.862e-10 1.27
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 1.130e-04 1.002e-04 1.803e-04 1.35
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 0.2271 0.2133 0.3115 1.22
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 3.540e-08 3.080e-08 6.780e-08 1.52
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.02261 -2.223 1.182 —

Climate change 0.2974 kg CO2 eq per m2. Main contributors: Disposal, ventilation equipment, decentralized, 180-250 m3 39 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 38 %; Disposal, overflow element, steel, approx. 40 m3/h 6 %; Disposal, air distribution housing, steel, 120 m3/h 3 %; Disposal, control and wiring, decentralized unit 3 %; Disposal, flexible duct, aluminum/PET, DN of 125 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Disposal, ventilation equipment, decentralized, 180-250 m3 39 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 38 %; Disposal, overflow element, steel, approx. 40 m3/h 6 %; Disposal, air distribution housing, steel, 120 m3/h 3 %; Disposal, control and wiring, decentralized unit 3 %; Disposal, flexible duct, aluminum/PET, DN of 125 2 %. Most sensitive exchanges (Section 6.3): Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] (-7.5 / +9.2 %); Disposal, sealing tape, aluminum/PE, 50 mm wide [CH] (-7.1 / +8.8 %); Disposal, overflow element, steel, approx. 40 m3/h [CH] (-1.2 / +1.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 3.692e-05 7.832e-05 0.471
Climate change-Biogenic 3.094e-05 3.094e-05 1.000
Climate change-Fossil 0.2973 0.2973 1.000
Climate change-Land use and land use change 5.300e-06 5.300e-06 1.000
Climate change 0.2974 0.2974 1.000
EF-particulate Matter 1.255e-09 1.255e-09 1.000
Ecotoxicity, freshwater_inorganics 0.8828 0.9166 0.963
Ecotoxicity, freshwater_organics 0.002172 0.002165 1.003
Ecotoxicity, freshwater 0.885 0.9187 0.963
Eutrophication marine 3.741e-05 3.740e-05 1.000
Eutrophication, freshwater 8.306e-06 8.306e-06 1.000
Eutrophication, terrestrial 2.915e-04 3.682e-04 0.792
Human toxicity, cancer_inorganics 1.442e-10 1.442e-10 1.000
Human toxicity, cancer_organics 2.164e-12 2.164e-12 1.000
Human toxicity, cancer 1.464e-10 1.464e-10 1.000
Human toxicity, non-cancer_inorganics 9.768e-10 9.747e-10 1.002
Human toxicity, non-cancer_organics 1.336e-11 1.336e-11 1.000
Human toxicity, non-cancer 9.901e-10 9.881e-10 1.002
Ionising radiation, human health 0.005374 0.005374 1.000
Land use 0.1642 0.1033 1.590
Ozone depletion 5.387e-10 5.387e-10 1.000
Photochemical ozone formation - human health 1.130e-04 1.130e-04 1.000
Resource use, fossils 0.2271 0.2272 1.000
Resource use, minerals and metals 3.540e-08 2.960e-08 1.196
Water use 0.02261 0.02273 0.995
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.2974 kg CO2 eq; Ecological Scarcity
2021 total 359.7 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] 0.003846 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -7.5 / +9.2 9.2 (Climate change-Fossil)
Disposal, sealing tape, aluminum/PE, 50 mm wide [CH] 0.8974 m ×0.81 / ×1.23 lognormal, GSD² 1.24 -7.1 / +8.8 21.7 (Human toxicity, cancer_inorganics)
Disposal, overflow element, steel, approx. 40 m3/h [CH] 0.02308 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.2 / +1.4 1.4 (Climate change-Fossil)
Disposal, air distribution housing, steel, 120 m3/h [CH] 0.01538 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.7 3.9 (Eutrophication marine)
Disposal, control and wiring, decentralized unit [CH] 0.003846 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.5 / +0.6 6.6 (Water use)
Disposal, flexible duct, aluminum/PET, DN of 125 [CH] 0.02564 m ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.4 / +0.5 0.6 (Eutrophication marine)
Disposal, outside air intake, stainless steel, DN 370 [CH] 9.615e-04 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.4 / +0.5 0.5 (Climate change-Fossil)
Disposal, building, bulk iron (excluding reinforcement), to sorting plant [CH] 1.644 kg ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.4 / +0.4 13.9 (Ionising radiation, human health)
Disposal, exhaust air valve, in-wall housing, plastic/steel, DN 125 [CH] 0.02308 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.3 / +0.3 8.6 (Water use)
Disposal, control and wiring, central unit [CH] 6.410e-04 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.2 / +0.2 2.9 (Water use)
Disposal, ventilation equipment, central, 600-1200 m3/h [CH] 6.410e-04 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.2 1.6 (Eutrophication, freshwater)
Disposal, air filter, decentralized unit, 180-250 m3/h [CH] 0.007692 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.2 0.2 (Eutrophication marine)
Disposal, air filter, in exhaust air valve [CH] 0.02308 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.2 0.2 (Eutrophication marine)
Disposal, silencer, steel, DN 125 [CH] 0.02308 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.1 7.0 (Eutrophication, freshwater)
Disposal, insulation spiral-seam duct, rockwool, DN 400, 30 mm [CH] 0.02564 m ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.1 7.7 (Eutrophication, freshwater)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.2974 kg CO2 eq per m2 (95 % interval 0.2503–0.367). Dominant contributors: Disposal, ventilation equipment, decentralized, 180-250 m3 39 %; Disposal, sealing tape, aluminum/PE, 50 mm wide 38 %; Disposal, overflow element, steel, approx. 40 m3/h 6 %; Disposal, air distribution housing, steel, 120 m3/h 3 %; Disposal, control and wiring, decentralized unit 3 %; Disposal, flexible duct, aluminum/PET, DN of 125 2 %. Most sensitive: Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] (-7.5 / +9.2 %); Disposal, sealing tape, aluminum/PE, 50 mm wide [CH] (-7.1 / +8.8 %); Disposal, overflow element, steel, approx. 40 m3/h [CH] (-1.2 / +1.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.1e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 18/18 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.2974 in [0.2503, 0.367]
time period declared PASS 1994-01/2008-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Primas A. (2008) Ökologische Bewertung von Gebäudetechnikanlagen für SIA 2032. Schlussbericht. Amt für Hochbauten der Stadt Zürich. Zürich. Type: Separate publication Source: Report First author: Primas A. Year: 2008 Title of anthology: Schlussbericht Place of publication: Zürich Publisher: Amt für Hochbauten der Stadt Zürich — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.