Table of Contents

Cable, ribbon cable, 20-pin, with plugs, at plant — GLO

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cable, ribbon cable, 20-pin, with plugs, at plant [GLO], per 1 kg. EF v3.1 climate change 8.569 kg CO2 eq (Monte Carlo 95 % interval 6.898–17.27). Main contributors: Zinc coating, pieces 43 %; Polyethylene, HDPE, granulate, at plant 18 %; Printed wiring board mounting plant 15 %; Injection moulding 8 %; Copper, primary, at refinery 5 %; Polyvinylchloride, at regional storage 4 %. Status: final control passed.
Item Value
Dataset name Cable, ribbon cable, 20-pin, with plugs, at plant
Dataset UUID / graph id 62d03858-9356-3a2c-a739-8f5040b431f8 / activity:cable_ribbon_cable_20_pin_with_plugs_at_plant__glo
Reference product, unit Cable, ribbon cable, 20-pin, with plugs, at plant, 1 kg
Location GLO — The data describes a typical ribbon cable in the years after 2000. The kind of ribbon cable is produced by international manufacturers and available all over the world. Therefore a global dataset is justifiable.
Time period 2023-01/2029-12
Category electronics / devices
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This dataset can be applied to describe the production of a typical 20-way ribbon cable to connect drives to the motherboard of a computer. The total weight of 1 unit of ribbon cable (with connector) is 0.0242 kg and the length 0.24 m, whereof the plugs weigh 0.0167 kg and the 20-cores cable 0.0075 kg. These weights have been extrapolated to 1 kg of ribbon cable (factor 1/0.0242). The information for this dataset is based on calculations and analyses at EMPA Laboratories. In 2023, only production efforts data are updated. Furthermore, material and energy input are now represented by global inventory flows; UUID: 62d03858-9356-3a2c-a739-8f5040b431f8

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Cable, ribbon cable, 20-pin, with plugs, at plant (GLO). All results are given per unit of the reference flow.

System boundary

Describes the production of a typical ribbon cable with connectors for a desktop computer. Calculated per 1 kg of ribbon cable. Included are the materials copper, brass, PVC and HDPE with their attributed manufacturing processes like wire drawing or extrusion. The infrastructure is calculated via the proxy “electronic component production plant”. Further inventoried are the electricity for the assembly of the connector, the fuel oil, propane and water input, the disposal of plastic and rubber parts, the VOC and methanol emissions created during the processing, plus the road and rail transportation for input materials from the regional storage to the production site. The accumulated hazardous waste is also reported.

Technology

The manufacturing process is represented through plastic extrusion (for HDPE and PVC), tin-coating, contouring (brass), and wire drawing (copper).

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Zinc coating, pieces technosphere RER 0.62441 m2 lognormal, GSD² 1.33 — 42.5 █████████
Polyethylene, HDPE, granulate, at plant technosphere RER 0.68678 kg lognormal, GSD² 1.33 — 18.2 ████
Printed wiring board mounting plant technosphere GLO 2.0800e-07 p lognormal, GSD² 3.11 — 14.9 ███
Injection moulding technosphere RER 0.68678 kg lognormal, GSD² 1.33 — 8.2 ██
Copper, primary, at refinery technosphere GLO 0.15496 kg lognormal, GSD² 1.33 — 4.9 █
Polyvinylchloride, at regional storage technosphere RER 0.15496 kg lognormal, GSD² 1.33 — 4.3 █
Electricity, medium voltage, production GLO, at grid technosphere GLO 0.61845 kWh lognormal, GSD² 1.25 — 4.2 █
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 0.025269 kg lognormal, GSD² 1.33 — 0.7 ·
Wire drawing, copper technosphere RER 0.15496 kg lognormal, GSD² 1.33 — 0.7 ·
Heat, heavy fuel oil, at industrial furnace 1MW technosphere RER 0.50064 MJ lognormal, GSD² 1.33 — 0.6 ·
Extrusion, plastic pipes technosphere RER 0.15496 kg lognormal, GSD² 1.33 — 0.5 ·
Transport, freight, lorry, fleet average technosphere RER 0.1 tkm lognormal, GSD² 2.12 — 0.2 ·
Disposal, hazardous waste, 25% water, to hazardous waste incineration technosphere CH 0.0030645 kg lognormal, GSD² 1.33 — 0.1 ·
Brass, at plant technosphere CH 0.0033058 kg lognormal, GSD² 1.33 — 0.1 ·
Tap water, at user technosphere RER 20.167 kg lognormal, GSD² 1.33 — 0.0 ·
Transport, freight, rail technosphere RER 0.2 tkm lognormal, GSD² 2.12 — 0.0 ·
Contour, brass technosphere RER 0.0033058 kg lognormal, GSD² 1.33 — 0.0 ·
Propane, butane, at refinery technosphere RER 1.8548e-04 kg lognormal, GSD² 1.33 — 0.0 ·
Methanol elementary air/Medium stack, <150 meters / Rural (<… 1.2903e-04 kg lognormal, GSD² 2.11 — 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Medium stack, <150 meters / Rural (<… 9.6774e-05 kg lognormal, GSD² 2.11 — 0.0 ·

Data quality

0 of 20 direct exchanges carry a declared pedigree, 20 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH)
extrapolations see Geography and Technology
sampling procedure Weighing and measuring of materials. Literature for electricity consumption (assembly), emissions and waste.
production volume unknown
uncertainty adjustments see Geography and Technology
validation details Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1464 0.1058 0.2523 1.57
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01968 0.01371 0.05346 1.98
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.545 6.87 17.24 1.61
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.004212 0.002633 0.01177 2.24
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.569 6.898 17.27 1.6
EF-particulate Matter Impact on human health disease incidence 5.218e-07 4.139e-07 1.280e-06 1.75
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 68.4 58.41 177.1 1.79
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.046 0.9683 2.33 1.62
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 69.44 59.63 178.7 1.78
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.01199 0.009068 0.02785 1.76
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.03483 0.02058 0.235 3.48
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.1508 0.1085 0.3414 1.82
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.543e-08 1.816e-08 7.979e-08 2.13
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.074e-09 1.869e-09 1.744e-08 3.05
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.850e-08 2.124e-08 8.748e-08 2.06
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 2.345e-06 1.636e-06 7.387e-06 2.21
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.024e-07 5.676e-08 2.371e-07 2.02
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 2.447e-06 1.716e-06 7.483e-06 2.17
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2.125 0.7905 15.9 4.64
Land use Soil quality index pt (soil quality index) 96.72 57.54 325.8 2.44
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 8.407e-07 6.734e-07 1.384e-06 1.44
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.04377 0.03501 0.08611 1.62
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 152.6 123.7 294.5 1.57
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 8.785e-04 -0.001394 0.005573 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 1.149 -2436 1257 —

Climate change 8.569 kg CO2 eq per kg. Main contributors: Zinc coating, pieces 43 %; Polyethylene, HDPE, granulate, at plant 18 %; Printed wiring board mounting plant 15 %; Injection moulding 8 %; Copper, primary, at refinery 5 %; Polyvinylchloride, at regional storage 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Zinc coating, pieces 43 %; Polyethylene, HDPE, granulate, at plant 18 %; Printed wiring board mounting plant 15 %; Injection moulding 8 %; Copper, primary, at refinery 5 %; Polyvinylchloride, at regional storage 4 %. Most sensitive exchanges (Section 6.3): Printed wiring board mounting plant [GLO] (-10.0 / +30.5 %); Zinc coating, pieces [RER] (-10.4 / +13.7 %); Polyethylene, HDPE, granulate, at plant [RER] (-4.4 / +5.9 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.1464 0.1495 0.980
Climate change-Biogenic 0.01968 0.01968 1.000
Climate change-Fossil 8.545 8.545 1.000
Climate change-Land use and land use change 0.004212 0.004212 1.000
Climate change 8.569 8.569 1.000
EF-particulate Matter 5.218e-07 5.218e-07 1.000
Ecotoxicity, freshwater_inorganics 68.4 70.02 0.977
Ecotoxicity, freshwater_organics 1.046 1.039 1.007
Ecotoxicity, freshwater 69.44 70.97 0.978
Eutrophication marine 0.01199 0.01199 1.000
Eutrophication, freshwater 0.03483 0.03483 1.000
Eutrophication, terrestrial 0.1508 0.1546 0.976
Human toxicity, cancer_inorganics 2.543e-08 2.538e-08 1.002
Human toxicity, cancer_organics 3.074e-09 3.074e-09 1.000
Human toxicity, cancer 2.850e-08 2.846e-08 1.002
Human toxicity, non-cancer_inorganics 2.345e-06 2.342e-06 1.001
Human toxicity, non-cancer_organics 1.024e-07 1.024e-07 1.000
Human toxicity, non-cancer 2.447e-06 2.444e-06 1.001
Ionising radiation, human health 2.125 2.125 1.000
Land use 96.72 67.74 1.428
Ozone depletion 8.407e-07 8.407e-07 1.000
Photochemical ozone formation - human health 0.04377 0.04377 1.000
Resource use, fossils 152.6 152.7 1.000
Resource use, minerals and metals 8.785e-04 8.719e-04 1.008
Water use 1.149 1.226 0.937
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 8.568 kg CO2 eq; Ecological Scarcity
2021 total 4.017e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Printed wiring board mounting plant [GLO] 2.080e-07 p ×0.329 / ×3.04 lognormal, GSD² 3.11 -10.0 / +30.5 131.8 (Land use)
Zinc coating, pieces [RER] 0.6244 m2 ×0.756 / ×1.32 lognormal, GSD² 1.33 -10.4 / +13.7 19.3 (Climate change-Land use and land use change)
Polyethylene, HDPE, granulate, at plant [RER] 0.6868 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -4.4 / +5.9 10.5 (Resource use, fossils)
Injection moulding [RER] 0.6868 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -2.0 / +2.6 13.2 (Ozone depletion)
Copper, primary, at refinery [GLO] 0.155 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -1.2 / +1.6 25.2 (Eutrophication, freshwater)
Polyvinylchloride, at regional storage [RER] 0.155 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -1.0 / +1.4 5.4 (Ozone depletion)
Electricity, medium voltage, production GLO, at grid [GLO] 0.6184 kWh ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.8 / +1.0 2.1 (Climate change-Biogenic)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 0.02527 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.2 / +0.2 0.2 (Climate change-Fossil)
Wire drawing, copper [RER] 0.155 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.2 / +0.2 0.6 (Climate change-Biogenic)
Transport, freight, lorry, fleet average [RER] 0.1 tkm ×0.479 / ×2.09 lognormal, GSD² 2.12 -0.1 / +0.2 1.9 (Climate change-Land use and land use change)
Heat, heavy fuel oil, at industrial furnace 1MW [RER] 0.5006 MJ ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.1 / +0.2 0.2 (Climate change-Fossil)
Extrusion, plastic pipes [RER] 0.155 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.1 / +0.1 0.6 (Climate change-Biogenic)
Transport, freight, rail [RER] 0.2 tkm ×0.479 / ×2.09 lognormal, GSD² 2.12 -0.0 / +0.0 0.2 (Climate change-Biogenic)
Disposal, hazardous waste, 25% water, to hazardous waste incineration [CH] 0.003064 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 0.1 (Ecotoxicity, freshwater_inorganics)
Brass, at plant [CH] 0.003306 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 0.1 (Human toxicity, non-cancer_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 8.569 kg CO2 eq per kg (95 % interval 6.898–17.27). Dominant contributors: Zinc coating, pieces 43 %; Polyethylene, HDPE, granulate, at plant 18 %; Printed wiring board mounting plant 15 %; Injection moulding 8 %; Copper, primary, at refinery 5 %; Polyvinylchloride, at regional storage 4 %. Most sensitive: Printed wiring board mounting plant [GLO] (-10.0 / +30.5 %); Zinc coating, pieces [RER] (-10.4 / +13.7 %); Polyethylene, HDPE, granulate, at plant [RER] (-4.4 / +5.9 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.2e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 20/20 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 8.569 in [6.898, 17.27]
time period declared PASS 2023-01/2029-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.