Table of Contents

Photovoltaic panel, CIS, at plant — DE

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Photovoltaic panel, CIS, at plant [DE], per 1 m2. EF v3.1 climate change 70.81 kg CO2 eq (Monte Carlo 95 % interval 37.34–186.5). Main contributors: Photovoltaic laminate, CIS, at plant 76 %; Aluminium alloy, AlMg3, at plant 22 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 2 %. Status: final control passed.
Item Value
Dataset name Photovoltaic panel, CIS, at plant
Dataset UUID / graph id 66202301-7079-30d9-b690-96ff555e7275 / activity:photovoltaic_panel_cis_at_plant__de
Reference product, unit Photovoltaic panel, CIS, at plant, 1 m2
Location DE
Time period 2002-01/2006-12
Category photovoltaic / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of photovoltaic thin film modules by thermal vaporization in vacuum. The modules produced at Würth Solar have a size of 1.2m by 0.6m. The weight is 12.6kg. The efficiency is 10.8%. The rated nominal power is about 78Wp per module.; Synonyms: Solarmodul, PV-module, copper indium selenide, thin film, CIGS; UUID: 66202301-7079-30d9-b690-96ff555e7275

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of Photovoltaic panel, CIS, at plant (DE). All results are given per unit of the reference flow.

System boundary

Electricity use, materials, transport of materials, treatment of production wastes. Disposal after end of life. Process emissions not known (except Cd).

Technology

Production technology of thin film CIS cells with thermal vaporization in vacuum.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Photovoltaic laminate, CIS, at plant technosphere DE 1 m2 lognormal, GSD² 3 (1,1,1,1,1,3) 75.5 ███████████████
Aluminium alloy, AlMg3, at plant technosphere RER 2.2 kg lognormal, GSD² 1.07 (1,1,1,1,1,3) 21.8 ████
Light fuel oil, burned in industrial furnace 1MW, non-modulating technosphere RER 15.5 MJ lognormal, GSD² 1.07 (1,1,1,1,1,3) 2.1 ·
Glass fibre reinforced plastic, polyamide, injection moulding, at plant technosphere RER 0.04 kg lognormal, GSD² 1.07 (1,1,1,1,1,3) 0.5 ·
Transport, freight, lorry, fleet average technosphere RER 0.224 tkm lognormal, GSD² 2.1 — 0.1 ·
Transport, freight, rail technosphere RER 1.344 tkm lognormal, GSD² 2.1 — 0.0 ·

Data quality

4 of 6 direct exchanges carry a declared pedigree, 6 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 1.0 · completeness 1.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 3.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Philippe Stolz (TREEZE); data entry: Philippe Stolz (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations
sampling procedure Literature data based on producer information.
production volume 14.8 MW planned for 2007
uncertainty adjustments
validation details Proof reading validation: 30.09.2020; Other validation: G:\Projekte laufend\174 Photovoltaic, IEA Task 12\2017 Global supply chain\EcoSpold[174-photovoltaics-global-supply-chain-v2.5.xlsx]X-Process;
time period comment Data refer to 2007. Production in 2006 was ramped up.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.2977 0.1408 0.872 2.58
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.4818 0.2125 1.454 2.74
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 70.29 37.04 185.2 2.3
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.04629 0.02514 0.1244 2.25
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 70.81 37.34 186.5 2.3
EF-particulate Matter Impact on human health disease incidence 2.890e-06 1.454e-06 3.507e-05 4.79
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 283.8 146.1 925.5 2.69
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 41.92 16.4 138.2 3
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 325.7 162.5 1064 2.7
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.06693 0.03273 0.2042 2.57
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.03669 0.01436 0.1739 3.74
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.6576 0.3047 2.017 2.73
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.534e-08 1.042e-08 5.886e-08 2.44
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.484e-08 1.493e-08 1.126e-07 2.86
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 5.018e-08 2.827e-08 1.641e-07 2.46
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.472e-07 4.725e-07 2.618e-06 2.54
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.965e-08 2.345e-08 1.646e-07 2.79
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 6.969e-07 5.003e-07 2.792e-06 2.54
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 19.58 6.176 129.8 4.95
Land use Soil quality index pt (soil quality index) 590.5 258.7 1873 2.8
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 1.472e-05 4.959e-06 4.713e-05 3.17
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.2172 0.1082 0.6799 2.58
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 967.2 501.9 2778 2.43
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 7.587e-04 2.519e-04 0.002872 3.48
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 7.351 -1.658e+04 9319 —

Climate change 70.81 kg CO2 eq per m2. Main contributors: Photovoltaic laminate, CIS, at plant 76 %; Aluminium alloy, AlMg3, at plant 22 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Photovoltaic laminate, CIS, at plant 76 %; Aluminium alloy, AlMg3, at plant 22 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 2 %. Most sensitive exchanges (Section 6.3): Photovoltaic laminate, CIS, at plant [DE] (-49.8 / +146.4 %); Aluminium alloy, AlMg3, at plant [RER] (-1.4 / +1.5 %); Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] (-0.1 / +0.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.2977 0.3114 0.956
Climate change-Biogenic 0.4818 0.4818 1.000
Climate change-Fossil 70.29 70.29 1.000
Climate change-Land use and land use change 0.04629 0.04629 1.000
Climate change 70.81 70.81 1.000
EF-particulate Matter 2.890e-06 2.890e-06 1.000
Ecotoxicity, freshwater_inorganics 283.8 286.9 0.989
Ecotoxicity, freshwater_organics 41.92 34.77 1.206
Ecotoxicity, freshwater 325.7 321.6 1.013
Eutrophication marine 0.06693 0.06692 1.000
Eutrophication, freshwater 0.03669 0.03669 1.000
Eutrophication, terrestrial 0.6576 0.6921 0.950
Human toxicity, cancer_inorganics 1.534e-08 1.493e-08 1.028
Human toxicity, cancer_organics 3.484e-08 3.484e-08 1.000
Human toxicity, cancer 5.018e-08 4.976e-08 1.008
Human toxicity, non-cancer_inorganics 6.472e-07 6.323e-07 1.024
Human toxicity, non-cancer_organics 4.965e-08 4.932e-08 1.007
Human toxicity, non-cancer 6.969e-07 6.817e-07 1.022
Ionising radiation, human health 19.58 19.58 1.000
Land use 590.5 489.8 1.206
Ozone depletion 1.472e-05 1.472e-05 1.000
Photochemical ozone formation - human health 0.2172 0.2172 1.000
Resource use, fossils 967.2 967.6 1.000
Resource use, minerals and metals 7.587e-04 7.135e-04 1.063
Water use 7.351 8.699 0.845
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 70.63 kg CO2 eq; Ecological Scarcity
2021 total 1.324e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Photovoltaic laminate, CIS, at plant [DE] 1 m2 ×0.34 / ×2.94 lognormal, GSD² 3 -49.8 / +146.4 190.6 (Ozone depletion)
Aluminium alloy, AlMg3, at plant [RER] 2.2 kg ×0.935 / ×1.07 lognormal, GSD² 1.07 -1.4 / +1.5 4.0 (Human toxicity, cancer_inorganics)
Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] 15.5 MJ ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.1 / +0.1 0.1 (Climate change-Fossil)
Transport, freight, lorry, fleet average [RER] 0.224 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.0 / +0.1 0.4 (Climate change-Land use and land use change)
Glass fibre reinforced plastic, polyamide, injection moulding, at plant [RER] 0.04 kg ×0.935 / ×1.07 lognormal, GSD² 1.07 -0.0 / +0.0 0.0 (Water use)
Transport, freight, rail [RER] 1.344 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.0 / +0.0 0.2 (Human toxicity, non-cancer_organics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 70.81 kg CO2 eq per m2 (95 % interval 37.34–186.5). Dominant contributors: Photovoltaic laminate, CIS, at plant 76 %; Aluminium alloy, AlMg3, at plant 22 %; Light fuel oil, burned in industrial furnace 1MW, non-modula… 2 %. Most sensitive: Photovoltaic laminate, CIS, at plant [DE] (-49.8 / +146.4 %); Aluminium alloy, AlMg3, at plant [RER] (-1.4 / +1.5 %); Light fuel oil, burned in industrial furnace 1MW, non-modulating [RER] (-0.1 / +0.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.0e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 6/6 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 70.81 in [37.34, 186.5]
time period declared PASS 2002-01/2006-12
geography is a known location code PASS DE
sources cited PASS 2 reference(s), of which 1 dataset source(s); 1 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Frischknecht Rolf Stolz Philippe Krebs Luana de Wild-Scholten Mariska Sinha Parikhit (2020). Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems. Office of Scientific and Technical Information (OSTI). https://doi.org/10.2172/2308831 — published source; matched in Crossref (author, year ±1, title overlap)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.