Table of Contents

xxx Photovoltaic panel, pc-Si, at plant — RER

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset xxx Photovoltaic panel, pc-Si, at plant [RER], per 1 p. EF v3.1 climate change 141.1 kg CO2 eq (Monte Carlo 95 % interval 121.8–202.8). Main contributors: xxx Photovoltaic cell, pc-Si , at plant 65 %; Aluminium alloy, AlMg3, at plant 12 %; Solar glass, low-iron, at regional storage 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 3 %; Ethylvinylacetate, foil, at plant 2 %; Tempering, flat glass 2 %. Status: final control passed.
Item Value
Dataset name xxx Photovoltaic panel, pc-Si, at plant
Dataset UUID / graph id 7851ecc2-de72-36a5-9a96-fa5402df46ae / activity:xxx_photovoltaic_panel_pc_si_at_plant__rer
Reference product, unit xxx Photovoltaic panel, pc-Si, at plant, 1 p
Location RER
Time period 9999-01/9999-12
Category material, obsolete / others, obsolete
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of solar panels with 72 solar cells a 125*125cm2 with a capacity of 166Wp. Production of 18000 panels per year.; Synonyms: PV-module; UUID: 7851ecc2-de72-36a5-9a96-fa5402df46ae

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of xxx Photovoltaic panel, pc-Si, at plant (RER). All results are given per unit of the reference flow.

System boundary

Production of the cell matrix, cutting of foils and washing of glass, production of laminate, isolation. Aluminium frame of the panel.

Technology

Modern production plant.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
xxx Photovoltaic cell, pc-Si , at plant technosphere RER 112.5 p lognormal, GSD² 1.21 — 64.8 █████████████
Aluminium alloy, AlMg3, at plant technosphere RER 2.4 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 11.9 ██
Solar glass, low-iron, at regional storage technosphere RER 11.5 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 9.0 ██
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 1.646 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 2.8 █
Ethylvinylacetate, foil, at plant technosphere RER 1.11 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 2.3 ·
Tempering, flat glass technosphere RER 11.5 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 2.0 ·
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 8 kWh lognormal, GSD² 3 — 1.6 ·
Aluminium, production mix, wrought alloy, at plant technosphere RER 0.224 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.8 ·
Aluminium, production mix, cast alloy, at plant technosphere RER 0.253 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.8 ·
Natural gas, burned in industrial furnace 1MW technosphere CH 14 MJ lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.8 ·
Synthetic rubber, at plant technosphere RER 0.36 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.7 ·
Photovoltaic panel factory technosphere GLO 4.0000e-06 p lognormal, GSD² 3.02 (1,4,1,3,1,3) 0.7 ·
Disposal, municipal solid waste, 22.9% water, to municipal incineration technosphere CH 1 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.4 ·
Polyester resin, unsaturated, at plant technosphere RER 0.06604 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.3 ·
Transport, freight, lorry, fleet average technosphere RER 2.0613 tkm lognormal, GSD² 2.1 — 0.3 ·
Polystyrene, high impact, HIPS, at plant technosphere RER 0.08 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.2 ·
Polyvinylidenchloride, granulate, at plant technosphere RER 0.05454 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.2 ·
Glass fibre reinforced plastic, polyamide, injection moulding, at plant technosphere RER 0.021 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.1 ·
Transport, freight, rail technosphere RER 9.7414 tkm lognormal, GSD² 2.1 — 0.1 ·
Disposal, polyvinylfluoride, 0.2% water, to municipal incineration technosphere CH 0.05454 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.1 ·
Corrugated board, mixed fibre, single wall, at plant technosphere RER 0.1 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.1 ·
Polyethylene, LDPE, granulate, at plant technosphere RER 0.02 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.0 ·
Epoxy resin, liquid, at plant technosphere RER 0.005 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.0 ·
Brazing solder, cadmium free, at plant technosphere RER 0.0121 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.0 ·
Disposal, used mineral oil, 10% water, to hazardous waste incineration technosphere CH 0.0071111 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Silicone product, at plant technosphere RER 0.004 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Treatment, sewage, from residence, to wastewater treatment, class 2 technosphere CH 0.027 m3 lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Tap water, at user technosphere RER 27 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Vinyl acetate, at plant technosphere RER 0.002 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Disposal, aluminium, 0% water, to municipal incineration technosphere CH 0.224 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.0 ·
Lubricating oil, at plant technosphere RER 0.0019556 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Methanol, at regional storage technosphere CH 0.0026233 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Calcium borates, at plant technosphere TR 0.0133 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Silica sand, at plant technosphere DE 0.006 kg lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.0 ·
Acetone, liquid, at plant technosphere RER 4.3933e-05 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Copper, at regional storage technosphere RER 6.7000e-07 kg lognormal, GSD² 1.13 (1,4,1,3,1,3) 0.0 ·
Waste Heat elementary air/Unknown 28.8 MJ lognormal, GSD² 1.29 (3,4,3,3,1,5) 0.0 ·

Data quality

33 of 37 direct exchanges carry a declared pedigree, 37 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.09 · completeness 4.0 · temporal 2.09 · geographical 3.0 · technological 1.0 · sample size 4.09.

Field As declared by the publisher
Data generator / entry / validation data generator: Niels Jungbluth (ESU); data entry: Niels Jungbluth (ESU); validation (proof reading): Silvio Blaser
extrapolations Number of cells 112.5 because of smaller size of cells.
sampling procedure Environmental reports and publication of plant data.
production volume Worldwide module production in 2000, 238MW (60%pc-Si, 40% mc-Si). Europe 23MW.
uncertainty adjustments none
validation details Proof reading validation: Passed.; Other validation: none;
time period comment Date of publication.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.8911 0.7033 1.328 1.38
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.066 1.88 6.338 1.88
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 137.9 119.1 198.7 1.29
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1124 0.09062 0.1679 1.38
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 141.1 121.8 202.8 1.29
EF-particulate Matter Impact on human health disease incidence 5.560e-06 4.785e-06 3.148e-05 2.52
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 849.9 739.2 1409 1.39
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 45.07 34.93 71.57 1.46
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 894.9 782.1 1466 1.38
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.3532 0.2674 0.5471 1.44
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.06569 0.04211 0.2177 2.29
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 3.198 2.314 5.147 1.5
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.065e-08 2.990e-08 8.998e-08 1.76
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.646e-08 3.621e-08 8.203e-08 1.52
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 7.711e-08 7.190e-08 1.531e-07 1.49
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.294e-06 1.379e-06 3.489e-06 1.6
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.508e-08 5.906e-08 1.096e-07 1.36
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.359e-06 1.444e-06 3.570e-06 1.58
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 53.28 18.92 330.7 4.52
Land use Soil quality index pt (soil quality index) 932.1 777.9 1613 1.45
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.152e-06 4.071e-06 9.147e-06 1.52
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.9634 0.7499 1.483 1.43
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 2192 1838 3475 1.37
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.06011 0.04413 0.08237 1.37
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 1580 -5.652e+04 3.201e+04 —

Climate change 141.1 kg CO2 eq per p. Main contributors: xxx Photovoltaic cell, pc-Si , at plant 65 %; Aluminium alloy, AlMg3, at plant 12 %; Solar glass, low-iron, at regional storage 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 3 %; Ethylvinylacetate, foil, at plant 2 %; Tempering, flat glass 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: xxx Photovoltaic cell, pc-Si , at plant 65 %; Aluminium alloy, AlMg3, at plant 12 %; Solar glass, low-iron, at regional storage 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 3 %; Ethylvinylacetate, foil, at plant 2 %; Tempering, flat glass 2 %. Most sensitive exchanges (Section 6.3): xxx Photovoltaic cell, pc-Si , at plant [RER] (-10.9 / +13.2 %); Solar glass, low-iron, at regional storage [RER] (-2.0 / +2.5 %); Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-1.0 / +3.0 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.8911 0.8946 0.996
Climate change-Biogenic 3.066 3.066 1.000
Climate change-Fossil 137.9 137.9 1.000
Climate change-Land use and land use change 0.1124 0.1124 1.000
Climate change 141.1 141.1 1.000
EF-particulate Matter 5.560e-06 5.560e-06 1.000
Ecotoxicity, freshwater_inorganics 849.9 856.1 0.993
Ecotoxicity, freshwater_organics 45.07 42.05 1.072
Ecotoxicity, freshwater 894.9 897.9 0.997
Eutrophication marine 0.3532 0.3532 1.000
Eutrophication, freshwater 0.06569 0.06569 1.000
Eutrophication, terrestrial 3.198 3.328 0.961
Human toxicity, cancer_inorganics 3.065e-08 2.976e-08 1.030
Human toxicity, cancer_organics 4.646e-08 4.646e-08 1.000
Human toxicity, cancer 7.711e-08 7.623e-08 1.012
Human toxicity, non-cancer_inorganics 1.294e-06 1.265e-06 1.023
Human toxicity, non-cancer_organics 6.508e-08 6.494e-08 1.002
Human toxicity, non-cancer 1.359e-06 1.330e-06 1.022
Ionising radiation, human health 53.28 53.28 1.000
Land use 932.1 713.1 1.307
Ozone depletion 5.152e-06 5.152e-06 1.000
Photochemical ozone formation - human health 0.9634 0.9634 1.000
Resource use, fossils 2192 2193 0.999
Resource use, minerals and metals 0.06011 0.06001 1.002
Water use 1580 1582 0.999
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 140.9 kg CO2 eq; Ecological Scarcity
2021 total 4.097e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
xxx Photovoltaic cell, pc-Si , at plant [RER] 112.5 p ×0.831 / ×1.2 lognormal, GSD² 1.21 -10.9 / +13.2 20.3 (Resource use, minerals and metals)
Solar glass, low-iron, at regional storage [RER] 11.5 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -2.0 / +2.5 5.8 (EF-particulate Matter)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 8 kWh ×0.341 / ×2.93 lognormal, GSD² 3 -1.0 / +3.0 10.5 (Ionising radiation, human health)
Aluminium alloy, AlMg3, at plant [RER] 2.4 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -1.3 / +1.5 3.9 (Human toxicity, cancer_inorganics)
Photovoltaic panel factory [GLO] 4.000e-06 p ×0.339 / ×2.95 lognormal, GSD² 3.02 -0.4 / +1.3 14.4 (Land use)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 1.646 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.6 / +0.8 0.8 (Climate change-Fossil)
Tempering, flat glass [RER] 11.5 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.4 / +0.6 0.7 (EF-particulate Matter)
Ethylvinylacetate, foil, at plant [RER] 1.11 kg ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.2 / +0.3 1.0 (Ecotoxicity, freshwater_organics)
Transport, freight, lorry, fleet average [RER] 2.061 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.1 / +0.3 1.4 (Climate change-Land use and land use change)
Aluminium, production mix, wrought alloy, at plant [RER] 0.224 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.2 / +0.2 0.9 (Human toxicity, cancer_inorganics)
Aluminium, production mix, cast alloy, at plant [RER] 0.253 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.2 / +0.2 0.8 (Human toxicity, cancer_inorganics)
Synthetic rubber, at plant [RER] 0.36 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.2 / +0.2 0.4 (Climate change-Land use and land use change)
Transport, freight, rail [RER] 9.741 tkm ×0.484 / ×2.06 lognormal, GSD² 2.1 -0.1 / +0.1 0.9 (Human toxicity, non-cancer_organics)
Natural gas, burned in industrial furnace 1MW [CH] 14 MJ ×0.89 / ×1.12 lognormal, GSD² 1.13 -0.1 / +0.1 0.1 (Resource use, fossils)
Polyester resin, unsaturated, at plant [RER] 0.06604 kg ×0.782 / ×1.28 lognormal, GSD² 1.29 -0.1 / +0.1 0.4 (Ecotoxicity, freshwater_inorganics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 141.1 kg CO2 eq per p (95 % interval 121.8–202.8). Dominant contributors: xxx Photovoltaic cell, pc-Si , at plant 65 %; Aluminium alloy, AlMg3, at plant 12 %; Solar glass, low-iron, at regional storage 9 %; Disposal, plastics, mixture, 15.3% water, to municipal incin… 3 %; Ethylvinylacetate, foil, at plant 2 %; Tempering, flat glass 2 %. Most sensitive: xxx Photovoltaic cell, pc-Si , at plant [RER] (-10.9 / +13.2 %); Solar glass, low-iron, at regional storage [RER] (-2.0 / +2.5 %); Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] (-1.0 / +3.0 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 37/37 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 141.1 in [121.8, 202.8]
time period declared PASS 9999-01/9999-12
geography is a known location code PASS RER
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Jungbluth, N., Stucki, M., Frischknecht, R. (2009) Photovoltaics. Sachbilanzen von Energiesystemen. Final report No. 6 ecoinvent v2.1. Editors: Bauer C.. Volume: 6. Swiss Centre for LCI, PSI. Dübendorf and Villigen, CH. Type: Measurement on site Source: CD-ROM First author: Jungbluth, N. Other authors: Stucki, M., Frischknecht, R. Year: 2009 Name of editors: Bauer C. Title of anthology: Sachbilanz… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.